KSCdirect

Product Data

KSCdirect Part #: CRH EPC61042
Description: EPC61042
MFG Part #: EPC61042
UPC: 782274313061
Supplier: COOPER CROUSE-HINDS
Usually ships in 1-2 days.
You will be notified of any delay and may cancel at that time.

Your Price: $18098.95 / EA

QTY:  
For shipping rates, add item to cart.
* Quantity discounts may be available. Call Kelly Supply at 800-918-8939.
Alternatively, you may e-mail info@kscdirect.com for service.

Details

Description

Crouse-Hinds ArktiteĀ® Interlocked Receptacle, Style 2 Explosionproof, Series: EPC, 480 VAC/250 VDC, 100 A, 4 Pole, 3 Wires, NEMA 3/7C/7D/9F/9G/12 Enclosure, Pressure Wire Terminal, Copper-Free Aluminum, 12-13/16 in L x 14-3/8 in W x 25-1/4 in H Dimensions

Features:

  • Explosionproof, dust-ignitionproof and raintight
  • Mechanical interlock mechanism for dead front construction
  • Receptacles are mechanically interlocked with circuit breakers to provide disconnect means, short circuit protection and thermal time delay overload protection
  • A spring door receptacle, located at bottom of 30, 60 and 100 a units and at front of 200 a units, is mechanically interlocked with the circuit breaker operating mechanism for maximum safety
  • Plug and receptacle contacts cannot be made or broken under load, the circuit breaker cannot be closed until the plug is fully inserted and the plug cannot be withdrawn unless the breaker is open
  • Operating handles can be padlocked in either on or off positions, breakers are trip-free of the handles and will open under short circuit or overload even if the handle is locked in the on position
  • Quick installation and leveling is provided by the three-point mounting arrangement which has one keyhole slot at top and two open slots at bottom
  • Bodies have four taper tapped conduit hubs with integral bushings
  • Two are located at top and two directly below
  • The EPC interlock receptacle is designed for use as a service outlet for portable equipment
  • It is designed for use in damp, wet and corrosive locations, indoors or outdoors, in areas which are hazardous due to flammable vapors, gases or combustible dust
  • 2 in hub
  • Fiberglass-reinforced polyester insulation
  • Without circuit breaker

Applications:

Industrial Facilities, Factories Facility, Power Distribution and Control, Refinery and Chemical Plant Applications

Standards/Approval:

  • ANSI Specified
  • UL 1010
  • Class I, Division 1/2, Group C/D, Class II, Division 1/2, Group F/G, Class III

Attributes/Specifications

Amperage Rating 100 A
Dimensions 12-13/16 in L x 14-3/8 in W x 25-1/4 in H
Enclosure NEMA 3/7C/7D/9F/9G/12
Material Copper-Free Aluminum
Number of Poles 4
Number of Wires 3
Series EPC
Terminal Type Pressure Wire
Type Style 2 Explosionproof
Voltage Rating 480 VAC/250 VDC
Manufacturer COOPER CROUSE-HINDS