The 24V Standing Pilot Natural Gas Valve 1/2" X 3/4" from NEUCO INC is designed for reliable gas flow control in heating applications. This valve features a robust construction that ensures durability and consistent performance. It is compatible with various gas systems, providing precise regulation of gas flow. The valve is designed to meet industry standards, ensuring safety and efficiency in operation. Its compact size allows for easy installation in tight spaces, making it ideal for residential and commercial heating systems. With its high-quality construction, this gas valve is a trusted choice for HVAC professionals.
Residential Comfort/Combustion : Combustion Controls : Gas Valves, Residential : Standing Pilot : VR8300 : VR8300A3518/U
Single Stage, 24 Vac, Standard Opening, Standing Pilot Gas Valve. 1/2 x 3/4". Set 3.5" WC
Overview
Gas valvesl for use in 24 Vac, gas-fired, standing pilot appliances with capacities from 30 to 300 cfh.
Features
- Gas valves include safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment.
- Compact size.
- Provide two automatic valves.
- Solenoid operated first automatic valve opens on thermostat call for heat; closes when call for heat ends.
- Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted.
- Meets codes requiring dual safety shutoff.
- Natural to LP and LP to Natural conversion kits available for standard and slow opening gas valves, not for step opening gas valves.
- All adjustments, wiring connections and pilot outlet are accessible from top of control.
- Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure.
- Compatible with ECO connector.
- LITE-RITE (OFF-PILOT-ON) lighting sequence.
Product Specifications
- Application
- Single Stage
- Dimensions (in.)
- 5 3/8 in. high x 4 1/16 in. wide x 2 11/16 in. deep
- Dimensions (mm)
- 135 mm high x 104 mm wide x 69 mm deep
- Includes
- Q340 Thermocouple; Natural to LP Conversion Kit; One 3/4" x 1/2" reducer bushing; 3/4" straight flange; ECO Adaptor
- Item Type
- Product
- Mounting
- 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
- Frequency
- 60 Hz
- Approvals, Underwriters Laboratories Inc.
- UL Component Recognized MCCZ2.MH5323
- Approvals, CSA
- CSA International: 112395
- Electrical Connections
- 1/4 in. quick-connect male terminals
- Voltage
- 24 Vac
- Operating Temperature Range (F)
- 0 F to 175 F
- Operating Temperature Range (C)
- -18 C to +79 C
- Body Pattern
- Straight-through
- Opening Characteristics
- Standard
- Pressure Ratings (psi)
- 1/2 psi
- Pressure Ratings (kPa)
- 3.5 kPa
- Inlet/Outlet Size (in.)
- 1/2 in. x 3/4 in.
- Pilot Gas Outlet
- Compression fitting for 1/4 in. OD tubing
- Pressure Tapping
- 1/8 in. NPT with plug
- Type of Fuel
- Natural (LP with included conversion kit)
- Capacity (kBtuh)
- At 1 in. wc p.d.-- 190,000 BTUh: 30,000 BTUh minimum: 290,000 BTUh maximum Natural Gas
- Approvals, Australian Gas Association
- 4717
- Pressure Regulator
- Standard
- Pressure Regulator Setpoint (in. wc)
- 3.5 in. WC
- Pressure Regulator Setpoint (kPa)
- 0.87 kPa
- Ignition Type
- Standing Pilot
- Anticipator Setting
-