The Honeywell Solid Core Sensor (Model CTS-05-050-VDC-001) is designed for accurate temperature and pressure monitoring in HVAC systems. This sensor features a solid core construction that enhances durability and reliability. With its compact design, it is easy to install in various applications, providing precise readings for optimal system performance. The sensor is compatible with a range of systems and complies with industry standards, ensuring safety and efficiency. Ideal for both commercial and industrial use, this sensor is essential for maintaining operational integrity and enhancing system efficiency.
Keywords: HONEYW HON CTS-05-050-VDC-001 CTS-05-050-VDC-001 HONEYWELL, INC 085267304825 Solid Core Current Sensor w/ 0-5VDC Output, 0-10/0-20/0-50 Amps
Commercial Building Controls : Sensors : Current Sensors : Solid Core Transmitter : CTS-05-050-VDC-001
Solid Core Current Sensor w/ 0-5VDC Output, 0-10/0-20/0-50 Amps
Overview
Depending on the model, current is converted into a linear and proportional output signal of 0-5 Vdc, 0-10 Vdc or 4-20 mA and monitored by a building management controller. These Fast acting current sensors are reliable and extremely easy to install.
Features
- Solid or split core loop-powered current transmitters for 4-20 mA models
- Solid or split core 0-5 or 0-10 Vdc models
- Fast response time
- Integral DIN rail mounting flange
- Easy wiring, polarity sensitive output
- Accepts up to a 350 MCM (17.3 mm) cable
- Operates up to 250 continuous amps
- True RMS versions are available
- RoHS and WEEE Complaint
- Limited 5 Year Warranty.
Product Specifications
- Application
- Excellent choice for new installations requiring load treading (current monitoring)
- Dimensions (in.)
- 2 17/64 in. high x 3 3/8 in. wide x 63/64 in. deep
- Dimensions (mm)
- 58 mm high x 86 mm wide x 25 mm deep
- Weight (lb)
- 0.22 lb
- Weight (kg)
- 0.1 kg
- Frequency
- 50 Hz to 60 Hz
- Approvals, Underwriters Laboratories Inc.
- Approved
- Operating Humidity Range (% RH)
- 0 to 95% RH, non-condensing
- Supply Voltage
- Induced from monitored conductor
- Operating Temperature Range (F)
- 5 F to 104 F
- Operating Temperature Range (C)
- -15 C to 40 C
- Approvals, CE
- Approved
- Enclosure
- UL94-5V/Burgundy
- Type
- Adjustable
- Accuracy
- 1.0% (2 to 100% FSO)
- Core Type
- Solid
- Maximum Current
- continuous--100 Amps; 150 Amps; 200 Amps: for 6 seconds--125 Amps; 225 Amps; 300 Amps;
- Jumper Settings
- Low; Middle; High
- Output Switch Rating
- 0 to 5 Vdc
- Isolation Voltage
- 2200 Vac
- Response Time
- <100 mS
- Aperture Size
- 3/4 in. (19 mm). Accepts up to 350 MCM (17.3 mm) cables.
- Approvals, Environmental Compliance
- RoHS-Directive 2002/95/EC, WEEE-Directive 2002/96/EC
- Current Ratings
- 0-50 Amps; 0-10 Amps; 0-20 Amps
- DIN Rail Size (in.)
- 1-3/8 in.
- DIN Rail Size (mm)
- 35 mm