KSCdirect

Product Data

KSCdirect Part #: MSA 10081116
Description: PAPR ASSY, OPT TL, HOOD, STD BATTERY
MFG Part #: 10081116
UPC:
Supplier: Approved Supplier
Please use Live Chat or call 800-918-8939 for exact lead time.

Your Price: $1482.34 / EA

QTY:  
For shipping rates, add item to cart.
* Quantity discounts may be available. Call Kelly Supply at 800-918-8939.
Alternatively, you may e-mail info@kscdirect.com for service.

Details

The Opt TL PAPR Assembly with Hood and Standard Battery is engineered for optimal respiratory protection in hazardous environments. This powered air-purifying respirator (PAPR) features a lightweight design and a comfortable hood that provides a secure fit. The standard battery offers extended usage time, ensuring reliable performance throughout your work shift. The assembly is compliant with safety standards, making it suitable for various applications, including industrial and healthcare settings. Its efficient filtration system protects against airborne contaminants, enhancing user safety.

[14]Instrument Repair Services
The Safety Company
Related Resources
[15]Response Respirator Selector
[16]Cartidge Life Expectancy Calculator
[17]Cartridge Change Test Program
[18]Regulatory Information
[19]Warranty Information
[20]Ask a Question
[21]Have Someone Call Me
[22]Image Library
OptimAir TL Powered Respirator
[23]HOME | [24]CATALOG | [25]AIR-PURIFYING RESPIRATORS | [26]POWERED
AIR PURIFYING RESPIRATORS (PAPRS) | OptimAir TL Powered Respirator
[27]Printable Version of This Page
[28]Email This Page
[29][OptimairTLpreview.jpg]
Enlarge Image
[pixel.gif]
[pixel.gif]
[pixel.gif]
[pixel.gif]
Principles of Operation
A battery operated blower brings air through the cartridge, up the
breathing tube and into the wearer's respirator inlet covering.
Approvals & Standards
NIOSH-APPROVED A variety of hood materials, styles and configurations
are all NIOSH-approved, including DuPont Tychem SL and QC with single
and double bib. A choice of hose connection is also available. Unit
has an APF of 1,000 (Assigned Protection Factor).
Applications
Asbestos, Mold & Lead Paint Abatement
Chemical
Hazardous Materials
Pharmaceutical
Hazards
Particulate and Dust
Toxic Atmosphere Non-IDLH
Product Information
MSA's OptimAir TL PAPR incorporates a sleek, low-profile design for
user comfort never before offered in a PAPR. All components, including
the motor blower, cartridges, and battery, are packaged in a single
hip-hugging housing. Improved motor blower electronics allow for
optimum air flow, while the compact and ergonomic battery pack affords
lightweight comfort and fit. Flow control sensors are activated by
insertion of the cartridges and breathing hose to the blower housing.
The unit automatically adjusts for altitude via an internal pressure
sensor.
Superior design features permit fast, accurate changeout of
cartridges, hoods and batteries. Slim, curved PAPR housing helps to
minimize fatigue and permits work in tight confined areas. Standard
OptimAir TL PAPR kit includes motor blower, smart charger, standard
battery, hose and decon belt.
DESIGN FEATURES
Crushproof breathing tube
Automatic setting of flow rates
Audible and visual alarms for low flow indication and low battery
voltage
Less bulk and better weight distribution improves worker efficiency
Sealing gaskets on each cartridge
Basic Info
Additional Product Information
* [30]Bulletin - OptimAir TL Powered Respirator
* [31]Bulletin - Key Elements of a Sound Respiratory Protection
Program (Bulletin No. 1000-61)
* [32]Bulletin - OptimAir TL Features & Benefits (Bulletin No.
1010-18)
* [33]NIOSH Approval Label - Optimair TL
* [34]SPECIAL OFFER - Click on this link for details

Technical Information
* [35]Instruction Manual - OptimAir TL Powered Respirator (Manual
Part No. 10077289)

Literature
Ordering Information
Part Number Description
10081116 OptimAir Kit, for hoods with standard battery
10077486 OptimAir Blower Unit
10083329 Tychem QC Hood, single bib, threaded connector,
w/suspension, 4-pack
10083330 Tychem QC Hood, double bib, threaded connector,
w/suspension, 4-pack
10083381 Tychem SL Hood, single bib, threaded connector,
w/suspension, 4-pack
10083382 Tychem SL Hood, double bib, threaded connector,
w/suspension, 4-pack
10083383 Tychem QC Hood, single bib, standard, w/suspension, 4-pack
10083384 Tychem QC Hood, double bib, standard, w/suspension, 4-pack
10086926 Tychem QC Hood, single bib, threaded connector,
w/suspension, 4-pack (Yellow)
10086925 Tychem QC Hood, double bib, threaded connector,
w/suspension, 4-pack (Yellow)
10083385 Tychem SL Hood, single bib, standard, w/suspension, 4-pack
10083386 Tychem SL Hood, double bib, standard, w/suspension, 4-pack
10083843 Hose clamp for standard hood, 6-pack
10085084 O Ring replacements, Hood Hose, 10-pack
10049631 Hood hose
10078469 Suspension only Tychem hood
10083618 Sweatband for hood suspension, 10-pack
10076108 Standard battery for OptimAir TL PAPR
10076110 Standard battery charger for OptimAir TL PAPR
10075799 Decon cover for OptimAir TL PAPR, 5-pack
10074725 Decon belt (Cam Lock Buckle)
10078201 Decon belt (BackPack Buckle)
10080455 HE cartridge, 6-pack, Hi-efficiency particulate
10080454 GMC HE cartridge, 6-pack, (organic vapors, acid gases, HE)
10080456 GME HE cartridge, 6-pack, (acid gases, ammonia,
formaldehyde, HE)
10081414 Cartridge receptacle cover
How to Order From MSA:
* [36]General Instructions
* [37]Locate an MSA Distributor
* [38]Locate an MSA Sales Manager
Ordering Info
[39] MSA 2008.

Keywords: MSA Mine Safety Appliances



Buy MSA Mine Safety Appliances Products and Replacement Parts

Attributes/Specifications

Manufacturer Approved Supplier

Supplemental Files

This item has no supplemental files.