KSCdirect Part #: CH MD51E88
Description: 51KVA DR Isol XFMR 3PH 230V D-230Y/133V
MFG Part #: MD51E88
UPC: 786680330155
Supplier: Cutler-Hammer
Please use Live Chat or call 800-918-8939 for exact lead time.

Your Price: $13512.44 / EA

QTY:  
For shipping rates, add item to cart.
* Quantity discounts may be available. Call Kelly Supply at 800-918-8939.
Alternatively, you may e-mail info@kscdirect.com for service.

Details

Description

Cutler-Hammer Motor Drive Isolation Transformer, Type MD Dry Ventilated, 230 VAC Primary, 230Y/133 V AC Secondary, 51 kVA Power, 60 Hz Frequency, 3 ph ph, 2 Taps, Screw Mounting, NEMA 2/3R Enclosure, 150 deg C, 26-1/8 in L x 19-1/8 in W x 39-3/8 in H Dimensions

Features:

  • Short-term overload capability as required by ANSI
  • Primary and secondary terminals are front accessible for fast and easy connection
  • Slotted screw mounting holes in enclosure and cover reduce installation time
  • Sound dampening pads, which isolate the core and coil from the case, reduce noise levels to meet NEMA ST-20
  • Core laminations of precision sheared silicon steel are hand stacked to ensure quiet operation
  • Terminations are clearly marked for easy identification
  • Three-phase transformers have one 5% full capacity tap above and below nominal voltage for incoming source adjustment
  • Units are suitable for continuous operation in a 40 deg C ambient maximum
  • Full current neutral
  • Thermoguard protection embedded in coils of three phase models to indicate that high temperatures (approximately 190 deg C) are present and thermoguards consist of a set of NO dry contacts
  • Three coil delta-wye configurations are used throughout the product line
  • 150 deg C rise standard (self extinguishing), 115 deg C or 80 deg C rise optional
  • Drive isolation transformers are specifically sized to the drive kVA requirements and are braced to withstand the mechanical stresses of current reversals and short circuits associated with SCR drives
  • Electrical isolation between the incoming line and the drive circuitry
  • Voltage conversion of input line to standard drive input voltages
  • Minimized line disturbances caused by SCR (silicon controlled rectifiers) firing
  • Reduced short-circuit currents and voltage line transients
  • DT-3 design
  • Aluminum coil
  • 1 at +5% FCAN, 1 at -5% FCBN tap

Applications:

Indoor and Outdoor Applications

Standards/Approval:

  • UL 506
  • 1561
  • ANSI C89.2
  • NEMA ST-20

Attributes/Specifications

Dimensions 26-1/8 in L x 19-1/8 in W x 39-3/8 in H
Enclosure Type NEMA 2/3R
Frequency Rating 60 Hz
Mounting Type Screw
Number of Taps 2
Phase 3
Power Rating 51 kVA
Primary Voltage 230 V AC
Secondary Voltage 230Y/133 V AC
Temperature Rating 150 deg C
Type Type MD Dry Ventilated
Manufacturer Cutler-Hammer