Description
EATON Soft Starter, N Frame Non-Combination Standard Severe Duty, Series: S811, 200 to 600 V AC, 37 A, 47/63 Hz Frequency, 11 kW Wattage, 150 hp, 200 hp Motor, 3 Pole, 15 s Timing, 3 ph, Solid-State Overload Relay, Open Enclosure, Starting Modes: Current Limit/Kick/Ramp, -30 to 50 deg C Operating, 11 x 9 x 11-1/2 in Dimensions
Features:
- Communication capabilities with various protocols
- Digital interface module (DIM) provides an intuitive, easy to use human interface with powerful configuration capabilities to maximize system performance
- Door or device mounted dim enables users to safely configure, commission, monitor and troubleshoot the system at the electrical panel without opening the enclosure door
- System operating parameters can be monitored enterprise wide through a communications network
- Increase uptime by providing data for process management and preventive diagnostics
- Run bypass mode greatly reduces internal heating created by the greater power dissipation in the SCRs
- Bypass contactors directly connect the motor to the line and improves system efficiency by reducing internal power losses
- Internal solid state overload protection provides accurate current measurement and trip settings
- Internal run bypass contactors and overload protection eliminate the need for additional devices, reducing enclosure sizes minimizing installation and wiring time and reducing overall assembly size and cost
- Wide range of overload FLA settings and a selectable trip class offers users the flexibility to fine tune the starter to match specific application requirements
- Variable ramp times and torque control settings provide unlimited starting configurations, allowing for maximum application flexibility
- Kick start feature enables soft starting of high friction loads
- Soft stop control for applications where an abrupt stop of the load is not acceptable
- Pump control option with sophisticated pump algorithms on both starting and stopping that minimize the pressure surges that cause water hammer
- 6 SCRs control all 3 motor phases, providing smooth acceleration and deceleration performance
- Soft acceleration and deceleration reduces wear on belts, gears, chains, clutches, shafts and bearings
- Reduce the peak inrush current's stress on the power system
- Minimize peak starting torque to diminish mechanical system wear and damage
- 30 s ramp or 450% current limit at 50 deg C, inside-the-delta connection
Applications:
Motor, Power Control Equipment, Electrical Assemblies, Panels and OEMs Applications
Standards/Approval: