The Honeywell TH114-A-024T/U is a low voltage non-programmable thermostat designed for 24V systems. It operates at 0.5A and features 15-minute cycles for efficient temperature control. This thermostat is ideal for residential applications, ensuring reliable performance without the complexity of programming. Its compact design allows for easy installation in various settings, making it a versatile choice for homeowners looking to maintain comfort with minimal effort.
0.5 A 24 V R, C, W 15 min. cycles OS BL
Residential Comfort/Combustion : Thermostats : Non-Programmable : TH114-A : TH114-A-024T/U
Low Volt Electric heating Manual Thermostat
Overview
The TH114 Series delivers the features that matter most in a non-programmable thermostat: an easy-to-read backlit display, slim contemporary design and percise temperature control.
Features
- Advanced temperature control ensures total comfort by minimizing temperature swings
- ON/STANDBY switch enables thermostat shutdown at the end of heating season for added security
- On-screen heating power indicator gives at-a-glance verification of power being used
- Backlit display
- Battery-free
Product Specifications
- Application
- Electric Heating; Baseboard heater; Radiant ceiling; Convector or Fan-forced Heater
- Dimensions (in.)
- 4.89 in. X 2.76 in. X 0.91 in.
- Dimensions (mm)
- 124 mm X 70 mm X 23 mm
- Used With
- Aube RC840/RC840T Series Electromechanical Relays
- Comments
- Backlight; On/Standby switch; 15-minute cycles
- Item Type
- Product
- Mounting
- Vertical
- Electrical Ratings
- 0.5 A / 24 VAC
- Supply Voltage
- 0.5 A, 24 VAC
- Switch Positions (System)
- AF/F (switch MUST be set to AF for this thermostat to be operational)
- Operating Temperature Range (F)
- 32 F to 122 F
- Operating Temperature Range (C)
- 0 C to 50 C
- Sensor Element
- Thermistor
- Accuracy (F)
- 0.9 F
- Accuracy (C)
- 0.5 C
- Differential Temperature (F)
- 1 F
- Differential Temperature (C)
- 0.5 C
- Color
- White
- Ambient Temperature Range (F)
- 32 F to 122 F
- Ambient Temperature Range (C)
- 0 C to 50 C
- Switch Type
- External electromechanical relay
- Power Method
- Hardwired
- Terminal Designations
- R, C, W
- Setting Temperature Range (F)
- 40 F to 86 F
- Setting Temperature Range (C)
- 5 C to 30 C
- Cycles per Hour
- 4
- Parts Needed for Operation (not included)
- Aube RC840/RC840T Series Electromechanical relays