The HONEYWELL NXBS0250CS30000000 is a 25HP NXS VFD COOLBLUE DRIVE designed for efficient motor control in industrial settings. Operating at 230V, this variable frequency drive (VFD) enhances energy efficiency and performance, allowing for precise speed control and reduced energy consumption. Its advanced cooling technology ensures optimal performance even under heavy loads. The drive is built to comply with industry standards, ensuring reliability and safety in various applications. Ideal for HVAC, pumps, and fans, this VFD is a versatile solution for modern automation needs.
Commercial Building Controls : Variable Frequency Drives : General Purpose Drives : NXS Drive with Cool Blue Bypass : NXBS0250CS30000000
25HP NXS VFD, COOLBLUE DRIVE ALONE
Overview
Variable Frequency Drives (VFD) accept a control input and then output tailored PWM control signal to operate (motors, fans, pumps, etc.) with maximum efficiency. The VFD can be field-programmed without any extra devices or computer connections.
Features
- Seven configurable applications built in.
- Easy commissioning through software or control panel.
- Devices can be wall-mounted or panel-mounted.
- Eleven protective functions (see Form 63-2600, Users Manual, Technical Data sections).
- Insulated gate bi-polar transistor (IGBT) technology.
- Modbus, BacNet, Device Net, Profibus, LobBus, NS available as options cards.
Product Specifications
- Dimensions (in.)
- 48H x 12D x 36W
- Dimensions (mm)
- 1176H x 294D x 882W
- Weight (lb)
- 193 lb
- Weight (kg)
- 424.6 kg
- Item Type
- Product
- Frequency
- 0 Hz to 320 Hz
- Voltage
- 230 Vac
- Operating Temperature Range (F)
- High Overload 14 to 122; Low Overload 14 to 104
- Operating Temperature Range (C)
- High Overload -10 to 50; Low Overload -10 to 40
- Enclosure
- NEMA 3R
- Relay Outputs
- 24 Vdc/8A; 125 Vdc/0.4A; 250 Vac/8A
- Horsepower
- 25 HP
- Current Ratings
- 75A
- Analog Current Output
- 0 (4) - 20 mA, max 500 ohm
- Bypass
- Drive alone
- Auto Bypass
- No
- Drive Family
- NXS
- Disconnect Type
- No Disconnect
- Pilot Lights
- No
- Control Transformer
- No
- Drive Input Disconnect
- No
- Drive Input Fuses
- No
- Type of RFI Filter
- Industrial filter
- Continuous Output Current
- overload 1.5 x High overload current (1min/10min); overload 1.1 x Low overload current (1min/10min)
- Starting Torque
- 200% High; 150% Low
- Peak Current
- 2 x high overload current, 2 seconds every 20 seconds
- Acceleration time
- 0 - 3000 sec
- Deceleration time
- 0 - 3000 sec
- Analog Voltage Input
- 0 - 10 Vdc , 200K ohm
- Analog Current Input
- 0 (4) - 20 mA, 250 ohm differential
- Digital Output
- 50 mA/48v open collector
- Reference Output Voltage
- +10V, +3%, max 10mA
- Auxiliary Voltage
- 24V, 15%, max 250 mA
- Frame Type
- FR7
- Layout
- Vertical