KSCdirect

Product Data

KSCdirect Part #: HON HVFDSB3B0050G231/U
Description: SMARTVFD BYPASS, 230 VAC,5 HP,NEMA 12, T
MFG Part #: HVFDSB3B0050G231/U
UPC: 85267341837
Supplier: HONEYWELL
Please use Live Chat or call 800-918-8939 for exact lead time.

Your Price: $3422.92 / EA

QTY:  
For shipping rates, add item to cart.
* Quantity discounts may be available. Call Kelly Supply at 800-918-8939.
Alternatively, you may e-mail info@kscdirect.com for service.

Details

The Honeywell SmartVFD Bypass is a 230 VAC, 5 HP solution designed for seamless motor control. This NEMA 12 rated unit provides protection against dust and moisture, making it ideal for indoor environments. The bypass feature allows for continuous operation during maintenance, ensuring minimal downtime. With its compact design and robust construction, this SmartVFD is perfect for various industrial applications, meeting all necessary compliance standards for safety and performance.


Commercial Building Controls : Variable Frequency Drives : SmartVFD HVAC : SmartVFD Bypass : HVFDSB3B0050G231/U

SmartVFD BYPASS, 230 Vac,5 HP,Graphical, NEMA 12 Enclosure, Three Contactor Bypass with Auto Bypass

Overview

The SmartVFD BYPASS is available in four configurations to meet your application needs: Disconnect Only, Two Contractor Bypass, Three Contractor Bypass, and Three Contractor with Auto-Bypass.

Features

  • Provides an economical means of bypassing the VFD
  • Freeze/Fire/Smoke Interlock
  • Fused Disconnect on some models
  • 3-Contactor bypass provides VFD isolation from power with motor running in BYPASS mode
  • 3-Contactor bypass provides TEST position powers the VFD without sending power to the motor
  • 3-Contactor Bypass with Auto-Bypass adds the control capabilities below to the standard three Contactor Bypass

Product Specifications

Dimensions (in.)
16 x 41 x 11
Dimensions (mm)
406 x 1041.4 x 279.4
Weight (lb)
70
Weight (kg)
31.75
Item Type
Product
Frequency
0 Hz to 320 Hz
Voltage
230 Vac
Operating Temperature Range (F)
14 F to 122 F
Operating Temperature Range (C)
-10 C to 50 C
Enclosure
NEMA 12
Relay Outputs
Max. switching load: 250Vac/2A or 250Vdc/0,4A
Horsepower
5 HP
Current Ratings
18A
Analog Current Output
0 (4) - 20 mA, max 500 ohm
Bypass
Drive with 3 contactor bypass and Auto bypass
Auto Bypass
Yes
Drive Family
SmartVFD HVAC
Contactor
3 Contactors
Disconnect Type
Fused
Pilot Lights
Yes
Drive Input Disconnect
Yes
Drive Input Fuses
Yes
Type of RFI Filter
EMC Filter
Continuous Output Current
overload 1.5 x High overload current (1min/10min); overload 1.1 x Low overload current (1min/10min)
Peak Current
2 x IN, 2 seconds every 20 second period
Acceleration time
0.1 - 3000 sec
Deceleration time
.1 - 3000 sec
Analog Voltage Input
0 - 10 Vdc , 200K ohm
Analog Current Input
0 (4) - 20 mA, 250 ohm differential
Digital Output
Open collector, max. load 48V/50mA
Reference Output Voltage
Maximum Load 10mA
Auxiliary Voltage
20%, max. load 50 mA
Frame Type
5

Attributes/Specifications

Category Commercial Building Controls
Manufacturer HONEYWELL
Product Variable Frequency Drives
Style Variable Frequency Drives

Supplemental Files

This item has no supplemental files.