KSCdirect

Product Data

KSCdirect Part #: STE 387335
Description: Filter-Regulator, 1/4"
MFG Part #: 387335
UPC:
Supplier: ALEMITE
Usually ships in 6 days.
You will be notified of any delay and may cancel at that time.

Your Price: $290.42 / EA

QTY:  
For shipping rates, add item to cart.
* Quantity discounts may be available. Call Kelly Supply at 800-918-8939.
Alternatively, you may e-mail info@kscdirect.com for service.

Details



Oil Mist System Accessories

Oil Mist System Accessories
Thermo-Aire Heater Kit 115 VAC
383808-A4 Thermo-Aire Heater Kit 115 VAC
* Used to heat incoming air for misting of high-viscosity oils that
do not mist at ambient temperatures (viscosities between 1,000 to
6,000 SSU @ 100F)
* Unit can also be used to increase and stabilize the air/oil ratio
of all oils under varying ambient temperatures
* Use with medium-output generators only
* 115 VAC
* 60/50 Hz
* Wattage: 600

Thermo-Aire Heater Kit 230 VAC
383808-B4 Thermo-Aire Heater Kit 230 VAC
* Used to heat incoming air for misting of high-viscosity oils that
do not mist at ambient temperatures (viscosities between 1,000 to
6,000 SSU @ 100F)
* Unit can also be used to increase and stabilize the air/oil ratio
of all oils under varying ambient temperatures
* Use with medium-output generators only
* 230 VAC
* 60/50 Hz
* Wattage: 600

Mist Monitor
387596 Mist Monitor
* Fiber-optic sensor is designed to continuously monitor the
established output of the oil mist generator
* Sensor responds to changes in air/oil ratio of mist passing
through the manifold
* Unit will provide an electronic alarm signal if the mist density
falls below preset limits
* Included Items: Electronic Control Cabinet, Fiber-Optic Cables,
Mist Manifold

Mist Pressure Switch
385033 Mist Pressure Switch
* Safety switch used to respond to drop or rise of oil mist line
pressure
* Can be used to energize a warning signal during machine operation
* May also be used to prevent machine startup when manifold pressure
is not within accepted limits
* Range of adjustment: .03 psi (0.8" H2O) to 3.0 psi (83" H2O)
* Factory set operating parameters: 8" H2O on falling pressure, 55"
H2O on rising pressure
* Contact rating: 10 amp @ 115 VAC and 230 VAC

Sight Assembly with bleed hole
385662 Sight Assembly with bleed hole
* Permits visual inspection of condensed oil after passing through a
bearing housing
* Includes a bleed hole to prevent oil from backing up into bearing
cavity
* Used with a dry sump
* Constructed of sturdy transparent acrylic
* Installed in the drain hole commonly provided at the bottom of a
bearing housing
* Connection: 1/2" NPT(m)

Sight Assembly without bleed hole
385662-A1 Sight Assembly without bleed hole
* Permits visual inspection of condensed oil after passing through a
bearing housing
* Used with a dry sump
* Constructed of sturdy transparent acrylic
* Installed in the drain hole commonly provided at the bottom of a
bearing housing
* Connection: 1/2" NPT(m)

Reservoir Refill Hose Assembly
380696 Reservoir Refill Hose Assembly
* 7', 3/8" I.D. hose
* 40 micron filter
* Loader coupler assembly
* Connect directly to pump (7181-4)

Air Filter/Regulator with Gauge
387335 Air Filter/Regulator with Gauge
* Removes water and particulates from incoming air supply
* Controls system pressure
* 5 micron element
* Automatic drain
* 1/4" NPT(f) ports
* Max. inlet pressure: 150 psi (10 bar)
* Max. outlet pressure: 60 psi (4 bar)

Alarm Annunciator 120 VAC
387275 Alarm Annunciator 120 VAC
* Provides visual and audible warning of system fault conditions,
including: low oil level, high mist pressure, low mist pressure,
low air temperature
* Selector switch can be used to disable the horn during trouble
shooting of the system fault
* Horn also features volume control
* Dry contacts included to energize a remote alarm (max. rating of
10 amp @ 120 VAC)

Alarm Annunciator 220 VAC
387275-A Alarm Annunciator 220 VAC
* Provides visual and audible warning of system fault conditions,
including: low oil level, high mist pressure, low mist pressure,
low air temperature
* Selector switch can be used to disable the horn during trouble
shooting of the system fault
* Horn also features volume control
* Dry contacts included to energize a remote alarm (max. rating of
10 amp @ 220 VAC)

Mounting Bracket
387344 Mounting Bracket
* Easy to install
* Provides convenient mounting of bare pint units 3922-A and 3922-B

Oil Mist Fluid Solenoid
383647-1 Oil Mist Fluid Solenoid
* Helps control refills of oil mist units

Air Solenoid Valve 120 VAC
387449-1 Air Solenoid Valve 120 VAC
* 120 VAC
* Shuts off air supply when machinery is not running
* 1/4" NPT(f) ports
* 1/2" NPT(f) conduit connection
* 16-VA holding current
* 30-VA inrush current

Air Solenoid Valve 220 VAC
387449 Air Solenoid Valve 220 VAC
* 220 VAC
* Shuts off air supply when machinery is not running
* 1/4" NPT(f) ports
* 1/2" NPT(f) conduit connection
* 16-VA holding current
* 30-VA inrush current

Oil Heater 120 VAC
387323 Oil Heater 120 VAC
* For gallon units
* 120 VAC
* Maintains oil at 100F (38C)
* 100 watt
* Recommended for outdoor installations or when ambient temperature
may drop below 70F (21C)

Oil Heater 220 VAC
387323-A Oil Heater 220 VAC
* For gallon units
* 220 VAC
* Maintains oil at 100F (38C)
* 100 watt
* Recommended for outdoor installations or when ambient temperature
may drop below 70F (21C)

Automatic Reservoir Filler for Medium-Output Generators 385787
Automatic Reservoir Filler for Medium-Output Generators Details
* Eliminates transporting oil
* Generators refilled automatically according to need
* Oil level is constantly maintained
* Eliminates spills
* Prevents contaminated oil from entering system

Automatic Reservoir Filler for High-Output Generators 385789
Automatic Reservoir Filler for High-Output Generators Details
* Eliminates transporting oil
* Generators refilled automatically according to need
* Oil level is constantly maintained
* Eliminates spills
* Prevents contaminated oil from entering system




Products
New Products
Lubrication Fittings
Grease Guns
Pumps
Centralized Lubrication Systems
Reels
Control Valves and Meters
Compressed Air Components
Fluid Management
Used Fluid Handling Equipment
Lubrication Accessories
Bulk Oil Systems
Quick Links
How to Buy
Product Literature and Service Sheets



Products / Centralized Lubrication Systems / Oil
Mist / Oil Mist Accessories
Oil Mist : Pint/Gallon Lubricator Models Medium-Output
Generators High-Output Generators High-Output Generators with
Thermo-Aire Heater Kit Fittings and Nozzles Oil Mist
Accessories
How to Buy

Oil Mist Accessories

Oil Mist Accessories
Thermo-Aire Heater Kit 115 VAC
383808-A4 Thermo-Aire Heater Kit 115 VAC
* Used to heat incoming air for misting of high-viscosity oils that
do not mist at ambient temperatures (viscosities between 1,000 to
6,000 SSU @ 100F)
* Unit can also be used to increase and stabilize the air/oil ratio
of all oils under varying ambient temperatures.
* Use with medium-output generators only
* 115 VAC
* 60/50 Hz
* Wattage: 600

Thermo-Aire Heater Kit 230 VAC
383808-B4 Thermo-Aire Heater Kit 230 VAC
* Used to heat incoming air for misting of high-viscosity oils that
do not mist at ambient temperatures (viscosities between 1,000 to
6,000 SSU @ 100F)
* Unit can also be used to increase and stabilize the air/oil ratio
of all oils under varying ambient temperatures
* Use with medium-output generators only
* 230 VAC
* 60/50 Hz
* Wattage: 600

Mist Monitor
387596 Mist Monitor
* Fiber-optic sensor is designed to continuously monitor the
established output of the oil mist generator
* Sensor responds to changes in air/oil ratio of mist passing
through the manifold
* Unit will provide an electronic alarm signal if the mist density
falls below preset limits
* Included Items: Electronic Control Cabinet, Fiber-Optic Cables,
Mist Manifold

Mist Pressure Switch
385033 Mist Pressure Switch
* Safety switch used to respond to drop or rise of oil mist line
pressure
* Can be used to energize a warning signal during machine operation
* May also be used to prevent machine startup when manifold pressure
is not within accepted limits
* Range of adjustment: .03 psi (0.8" H2O) to 3.0 psi (83" H2O)
* Factory set operating parameters: 8" H2O on falling pressure, 55"
H2O on rising pressure
* Contact rating: 10 amp @ 115 VAC and 230 VAC

Sight Assembly with bleed hole
385662 Sight Assembly with bleed hole
* Permits visual inspection of condensed oil after passing through a
bearing housing
* Includes a bleed hole to prevent oil from backing up into bearing
cavity
* Used with a dry sump
* Constructed of sturdy transparent acrylic
* Installed in the drain hole commonly provided at the bottom of a
bearing housing
* Connection: 1/2" NPT(m)
* For use with High-Volume Bucket Pump (7181-4)

Sight Assembly without bleed hole
385662-A1 Sight Assembly without bleed hole
* Permits visual inspection of condensed oil after passing through a
bearing housing
* Used with a dry sump
* Constructed of sturdy transparent acrylic
* Installed in the drain hole commonly provided at the bottom of a
bearing housing
* Connection: 1/2" NPT(m)
* For use with High-Volume Bucket Pump (7181-4)

Reservoir Refill Hose Assembly
380696 Reservoir Refill Hose Assembly
* 7', 3/8" I.D. hose
* 40-micron filter
* Loader coupler assembly
* Connect directly to pump (7181-4)

Air Filter/Regulator with Gauge
387335 Air Filter/Regulator with Gauge
* Removes water and particulates from incoming air supply
* Controls system pressure
* 5-micron element
* Automatic drain
* 1/4" NPT(f) ports
* Max. inlet pressure: 150 psi (10 bar)
* Max. outlet pressure: 60 psi (4 bar)

Alarm Annunciator 120 VAC
387275 Alarm Annunciator 120 VAC
* Provides visual and audible warning of system fault conditions,
including: low oil level, high mist pressure, low mist pressure,
low air temperature
* Selector switch can be used to disable the horn during trouble
shooting of the system fault
* Horn also features volume control
* Dry contacts included to energize a remote alarm (max. rating of
10 amp @ 120/220 VAC)

Alarm Annunciator 220 VAC
387275-A Alarm Annunciator 220 VAC
* Provides visual and audible warning of system fault conditions,
including: low oil level, high mist pressure, low mist pressure,
low air temperature
* Selector switch can be used to disable the horn during trouble
shooting of the system fault
* Horn also features volume control
* Dry contacts included to energize a remote alarm (max. rating of
10 amp @ 120/220 VAC)

Mounting Bracket
387344 Mounting Bracket
* Easy to install
* Provides convenient mounting of bare pint units 3922-A and 3922-B

Oil Mist Fluid Solenoid
383647-1 Oil Mist Fluid Solenoid
* Helps control refills of oil mist units

Air Solenoid Valve 120 VAC
387449-1 Air Solenoid Valve 120 VAC
* 120 VAC
* Shuts off air supply when machinery is not running
* 1/4" NPT(f) ports
* 1/2" NPT(f) conduit connection
* 16-VA holding current
* 30-VA inrush current

Air Solenoid Valve 220 VAC
387449 Air Solenoid Valve 220 VAC
* 220 VAC
* Shuts off air supply when machinery is not running
* 1/4" NPT(f) ports
* 1/2" NPT(f) conduit connection
* 16-VA holding current
* 30-VA inrush current

Oil Heater 120 VAC
387323 Oil Heater 120 VAC
* For gallon units
* 120 VAC
* Maintains oil at 100F (38C)
* 100 watt
* Recommended for outdoor installations or when ambient temperature
may drop below 70F (21C)

Oil Heater 220 VAC
387323-A Oil Heater 220 VAC
* For gallon units
* 220 VAC
* Maintains oil at 100F (38C)
* 100 watt
* Recommended for outdoor installations or when ambient temperature
may drop below 70F (21C)

Automatic Reservoir Filler for Medium-Output Generators 385787
Automatic Reservoir Filler for Medium-Output Generators Details
* Place pump directly into 55-gallon drum at generator location
* Eliminates transporting oil
* Generators refilled automatically according to need
* Oil level is constantly maintained
* Eliminates spills
* Prevents contaminated oil from entering system
* Maintains constant oil temperature
* Included Items: 2:1 Ratio Pump, FRL, Shut-off Valve, 7' Connecting
Hose

Automatic Reservoir Filler for High-Output Generators 385789
Automatic Reservoir Filler for High-Output Generators Details
* Place pump directly into 55-gallon drum at generator location
* Eliminates transporting oil
* Generators refilled automatically according to need
* Oil level is constantly maintained
* Eliminates spills
* Prevents contaminated oil from entering system
* Maintains constant oil temperature
* Included Items: 2:1 Ratio Pump, FRL, Shut-off Valve, 7' Connecting
Hose



Keywords: Alemite Lubrication Systems, fluid handling, Parts and service kits.


Products ; Lubrication Accessories ; Centralized Lubrication System Accessories ;Oil Mist Systems

Attributes/Specifications

Manufacturer ALEMITE

Supplemental Files

This item has no supplemental files.