KSCdirect

Product Data

KSCdirect Part #: MSA 492827
Description: BELT ASSEMBLY, PAPR, 6A, URETHANE
MFG Part #: 492827
UPC:
Supplier: Approved Supplier
Usually ships in 5 days.
You will be notified of any delay and may cancel at that time.

Your Price: $46.37 / EA

QTY:  
For shipping rates, add item to cart.
* Quantity discounts may be available. Call Kelly Supply at 800-918-8939.
Alternatively, you may e-mail info@kscdirect.com for service.

Details


[1]MSA MSA North America

MSA is the global leader in the development, manufacture and supply of
sophisticated products that protect people's health and safety.
[9]MSA Customer Service [10]Customer Service
1-800-MSA-2222
[11]MSA Sales Manager Locator [12]Sales Manager Locator
[13]Instrument Repair Services [14]Instrument Repair Services
The Safety Company
[15]HOME | [16]CATALOG | [17]LAW ENFORCEMENT/MILITARY PRODUCTS |
[18]LAW ENFORCEMENT PRODUCTS | [19]TACTICAL/BALLISTICS EQUIPMENT |
[20]OPTIMAIR 6A PAPR WITH OPTIFILTER CARTRIDGES | 492827
MSA Part Number: 492827
Engineering Description: BELT ASSY.URETHANE PAPR
Base Unit of Measure: EA
Material Dimensions: 8.00 L X 8.00 W X 2.00 H
Net Weight: 0.514
[21] MSA 2008.

Keywords: MSA Mine Safety Appliances

[14]Instrument Repair Services
The Safety Company
OptimAir 6A Accessories
[15]HOME | [16]CATALOG | [17]AIR-PURIFYING RESPIRATORS | [18]POWERED
AIR PURIFYING RESPIRATORS (PAPRS) | OptimAir 6A Accessories
[19]Printable Version of This Page
[20]Email This Page
[21][SorryNoImagePreview.jpg]
Enlarge Image
[pixel.gif]
[pixel.gif]
[pixel.gif]
[pixel.gif]
Principles of Operation
Not applicable
Approvals & Standards
Not applicable
Applications
Asbestos Abatement
Chemical
Electric Utility
Hazardous Materials
Nuclear
Oil and Gas
Paper & Pulp
Hazards
Particulate and Dust
Toxic Atmosphere Non-IDLH
Welding
Product Information
Flow Tester - The Flow tester is a thin plate orifice meter for
testing the volumetric flow rate delivered by an MSA OptimAir PAPR.
Field Test Unit - Quickly evaluates the electrical components of an
OptimAir 6 or 6A PAPR. Protective Cover - Protects PAPR from water
(such as asbestos decontamination showers) or particulate
contamination. Flow Check Devices - Allow users of PAPRs to quickly
and conveniently verify that their unit is providing the required air
flow.
Basic Info
Additional Product Information
* [22]Bulletin - Key Elements of a Sound Respiratory Protection
Program (Bulletin No. 1000-61)

Technical Information
* [23]Instruction Manual - PAPR Flow Tester (Manual Part No. 490157)

Literature
How to Order From MSA:
* [24]General Instructions
* [25]Locate an MSA Distributor
* [26]Locate an MSA Sales Manager
Frequently Ordered Part Numbers:

[27]468486 FIELD TEST UNIT,PAPR
[28]473902 BELT,WAIST,PVC,
[29]487895 COVER,PROT.,PAPR 6 CFM
[30]487995 METER,FLOW CHECK,TUBE
[31]488903 TESTER,FLOW PAPR OPT 6
[32]489999 ADAPTER,TUBE ASSY,PAPR
[33]491046 ADAPTER ASSY,MMPAPR
[34]492827 BELT ASSY.URETHANE PAPR
[35]800340 FLOW INDICATOR ASSEMBLY
[36]803903 STRAP,SHOULDER,PAPR,PACK.
[37]808494 KIT,COVER,PROTECTIVE,6A P,5/PKG
[38]9961 BELT ASSY,WAIST,NYLON WEBBING,BLACK,52"
Ordering Info
[39] MSA 2008.

Keywords: MSA Mine Safety Appliances

[14]Instrument Repair Services
The Safety Company
Related Products
[15]OptimAir Replacement Facepieces
[16]OptimAir 6A Accessories
[17]Towelettes
[18]Bitrex Qualitative Fit Test Kit
[19]Saccharin Qualitative Fit Test Kit
[20]Banana Oil Fit Test Kit
[21]Probed Respirator Facepieces for Fit Testing
[22]Confidence Plus Germicidal Cleaner
[23]OptimAir 6A Replacement Parts
Related Resources
[24]Response Respirator Selector
[25]Cartidge Life Expectancy Calculator
[26]Cartridge Change Test Program
[27]Regulatory Information
[28]Warranty Information
[29]Ask a Question
[30]Have Someone Call Me
[31]Image Library
OptimAir 6A PAPR with OptiFilter Cartridges
[32]HOME | [33]CATALOG | [34]LAW ENFORCEMENT/MILITARY PRODUCTS |
[35]LAW ENFORCEMENT PRODUCTS | [36]TACTICAL/BALLISTICS EQUIPMENT |
OptimAir 6A PAPR with OptiFilter Cartridges
[37]Printable Version of This Page
[38]Email This Page
[39][OptimAir6APreview.jpg]
Enlarge Image
[pixel.gif]
[pixel.gif]
[pixel.gif]
[pixel.gif]
Principles of Operation

The OptimAir 6A powered air-purifying respirator (PAPR) provides
respiratory protection by filtering contaminants from ambient air and
providing air flow to either a facepiece or hood (with HEPA filters
only) at a rate equal to or exceeding National Institute for
Occupational Safety and Health (NIOSH) standards.
Approvals & Standards

The OptimAir 6A powered air-purifying respirator (PAPR) with Ultravue,
Comfo, Comfo Elite, or Comfo Welder's facepieces or Tyvek hood has
approvals from the National Institute for Occupational Safety and
Health (NIOSH) and the Mine Safety and Health Administration (MSHA).
Filters and cartridges are covered by separate approval. Cartridges
must be replaced whenever air flow drops below four cubic feet per
minute (115 lpm) with tight-fitting facepieces, six cubic feet per
minute (170 lpm) with the Tyvek hood or when the user smells or tastes
the contaminant.
Applications
Asbestos Abatement
Chemical
Electric Utility
Hazardous Materials
Nuclear
Oil and Gas
Paper & Pulp
Sanding & Grinding
Hazards
Particulate and Dust
Toxic Atmosphere Non-IDLH
Product Information

The OptimAir 6A powered air-purifying respirator (PAPR) can be used
with an entire family of filters, chemical cartridges and combination
cartridges for protection against particulates, toxic gases and vapors
or a combination of these hazards. Requiring two filters, the unit is
available with full- or half-mask facepiece, or hood. The belt-mounted
motor/blower assembly includes an efficient 4.6 volt motor which has a
long service life. The motor/blower assembly features threaded
connectors for quick and easy attachment of OptiFilter cartridges.
Basic Info
Additional Product Information
* [40]Bulletin - Personal Protection During Mold Remediation
(Bulletin No. 5555-169-MC)
* [41]Bulletin - Gas Masks for Law Enforcement (Bulletin No.
5555-166-MC)
* [42]NIOSH Approval Label
* [43]Bulletin - Key Elements of a Sound Respiratory Protection
Program (Bulletin No. 1000-61)

Technical Information
* [44]Instruction Manual - Replacement Hood Kit for use with
Versa-Hood Respirators (Manual No. 488790)
* [45]OptimAir 6A Data Sheet No. 10-00-09
* [46]OptimAir 6A Instruction Manual (Part No. 490883)
* [47]Instruction Manual - PAPR Flow Tester (Manual Part No. 490157)

Literature
How to Order From MSA:
* [48]General Instructions
* [49]Locate an MSA Distributor
* [50]Locate an MSA Sales Manager
Frequently Ordered Part Numbers:

[51]492827 BELT ASSY.URETHANE PAPR
[52]471218 FCPC UV PKG SM BK HYCAR W/NC & SD
[53]480122 FCPC.HM,CHIN,S.E.MD HYCBL
[54]480125 FCPC.HM,CHIN,S.E.MD SILBL
[55]480127 FCPC.HM,CHIN,S.E.HYC BL
[56]480130 FCPC.HM,CHIN,S.E.SIL BL
[57]480132 FCPC.HM,CHIN,S.E.LG HYCBL
[58]480135 FCPC.HM,CHIN,S.E.LG SILBL
[59]481980 TUBE BREATHING HOOD,PAPR
[60]484198 FCPC ASSY,HM,DN,CHK,SE,MD
[61]484204 FCPC ASSY,HM,DN,CHK,SE,SM
[62]484210 FCPC ASSY,HM,DN,CHK,SE,LG
[63]486364 BREATHING TUBE ASSY,FCPC,PAPR
[64]486485 HOOD,OPTIMAIR 6A PAPR,W/SUSP/LENS,SHLDR
[65]488721 HOOD,OPTIMAIR 6A PAPR,W/O SUSP,TYVEK
[66]808494 KIT,COVER,PROTECTIVE,6A P,5/PKG
[67]10011890 CANISTERS,THREADED,P100/HE/CS/CN
[68]463471 CHARGER,BATTERY, WITH LOW VOLTAGE INDIC.
[69]484197 FCPC ASSY,HM,DN,CHK,SE,MD
[70]484203 FCPC ASSY,HM,DN,CHK,SE,SM
[71]484209 FCPC ASSY,HM,DN,CHK,SE,LG
[72]486614 CHARGER,DUAL RATE,PAPR,PK
[73]491102 MOTOR/BLOWER ASSY,OPTIMAIR 6A,BRUSH TYPE
[74]491120 BATTERY PACK,OPTIMAIR 6A
[75]491301 PAPR ASSY,OPTIMAIR 6A,WCART,W/TYVEK HOOD
[76]494236 PAPR ASSY,OPTIMAIR 6A,W/O CART,MD ULTRAV
[77]800749 OPTIMAIR 6A PAPR, MED,BLK
[78]800767 OPTIMAIR 6A PAPR, MED,BLK
[79]804564 TYVEK HOOD ASSY,PAPR,50UN
[80]816892 OPTIMAIR 6A PAPR,MD,HYCAR
[81]816912 BATTERY PACK, PACKAGED
Ordering Info
[82] MSA 2008.

Keywords: MSA Mine Safety Appliances

[14]Instrument Repair Services
The Safety Company
Related Resources
[15]Response Respirator Selector
[16]MSA Fire Service Website
[17]Regulatory Information
[18]Repair Education - CARE
[19]Warranty Information
[20]Ask a Question
[21]Have Someone Call Me
[22]Image Library
Support Belts
[23]HOME | [24]CATALOG | [25]SUPPLIED AIR RESPIRATORS | [26]AIR LINE
RESPIRATORS | [27]AIR LINE SYSTEM COMPONENTS AND COMPLIMENTARY
PRODUCTS | Support Belts
[28]Printable Version of This Page
[29]Email This Page
[30][SupportBeltsPreview.jpg]
Enlarge Image
[pixel.gif]
[pixel.gif]
[pixel.gif]
[pixel.gif]
Applications
Chemical
Construction
Electric Utility
Hazardous Materials
Nuclear
Oil and Gas
Paper & Pulp
Sanding & Grinding
Spray Painting
Welding
Hazards
Confined Space
Oxygen Deficiency
Toxic Atmosphere IDLH
Toxic Atmosphere Non-IDLH
Product Information
MSA PVC belts are easy to decontaminate. If decontamination is not a
factor, users may opt for an uncoated nylon web belt.
Basic Info
Literature
How to Order From MSA:
* [31]General Instructions
* [32]Locate an MSA Distributor
* [33]Locate an MSA Sales Manager
Frequently Ordered Part Numbers:

[34]473902 BELT,WAIST,PVC,
[35]492827 BELT ASSY.URETHANE PAPR
[36]497982 MOD #3630 0 TO 1.0% CO2
[37]9961 BELT ASSY,WAIST,NYLON WEBBING,BLACK,52"
Ordering Info
[38] MSA 2008.

Keywords: MSA Mine Safety Appliances



Keywords: MINESA MSA 492827 MINE SAFETY APPLIANCES CO BELT ASSY.URETHANE PAPR


Category:
[0] => SUPPLIER DIRECTORY => MINE SAFETY APPLIANCES CO, MSA => MSA - MINE SAFETY APPLIANCES - SECTION 80

Buy MSA Mine Safety Appliances Products and Replacement Parts

Attributes/Specifications

Manufacturer Approved Supplier

Supplemental Files

This item has no supplemental files.