Distributor
Environmental & Combustion Controls
> Y8610
Y8610U4001
Y-pack containing S8610U3009 and VR8204A2142 with 1/2 inch by 1/2 inch
inlet/outlet, flange kit, LP conversion kit
Locate Distributors
Product Specifications Literature and
Documents
Overview
Complete kits converting conventional standing pilot system to
intermittent pilot system. For use with 24 Vac gas-fired atmospheric
furnaces, boiler and heating appliances.
Features
o Y8610U kits are for use with natural or LP gas: provides 100
percent pilot gas shutoff if pilot fails to light; after 6-minute
delay, trial for ignition is repeated.
o Ignition trail/delay sequence is repeated until the appliance
lights or call for heat is removed.
Product Specifications Back To Top
Description Provide electronic control of intermittent pilot ignition
systems used on gas fired furnaces, boilers, and other heating
appliances.
Ignition System Type Intermittent Pilot
Ignition Sequence Continuous retry, after trial for ignition, pilot
gas shuts off for 5 minutes, then another trial for pilot ignition
takes place
Typical Gas Control VR8204, VR8304
Type of Gas Natural or LP
Flame Sense Single Rod or Two Rods
Ignition Source Internal high voltage spark generator
PrePurge 0 or 30 seconds
Ignition Trials To Lockout continuous retry
Lockout Timing 15 or 90 seconds
Ignition Trial Time (sec) 15 or 90 seconds
Maximum Valve Load @ 24 Vac (Amps) 1A Pilot, 2A Main @ 24Vac
Typical Ignition Hardware Q345, Q3451
Dimensions (in.) 3 15/16 in. high x 5 7/16 in. wide x 2 5/8 in. deep
Dimensions (mm) 100 mm high x 138 mm wide x 67 mm deep
Electrical Ratings 24 Vac
Frequency 60 Hz
Maximum Ambient Temperature (F) -40 F to +165 F
Maximum Ambient Temperature (C) -40 C to +74 C
Includes VR8204A2142 valve (1/2 x 1/2; 3.5" WC setting; 150 kBtu/hr at
1" p.d.)
Flame Failure Response Time (sec) 2.0 sec
Literature and other Resources Download
Back To Top
Owners Manual - (Y8610U4001, Y8610U6006 Homeowners Guide)
Product Data - (Y8610U Intermittent Pilot Retrofit Kit)
Sell Sheet - (Y8610U Y8610U Universal IP Retrofit Ignition System Kit)
Product Data - (Y8610U Intermittent Pilot Retrofit Kit)
Product Data - (Y8610U Juego do Modificacion Retroactivea de Piloto
Intermitente)
Product Data - (Y8610F, Y8610H Intermittent Pilot Retrofit Kit)
Download -Submit
Welcome
Category: SUPPLIER DIRECTORY => HONEYWELL, INC
February 2009
> Y8610
Residential Comfort/Combustion : Combustion Controls : Universal Replacement Parts : Universal Ignition Modules : Y8610U4001/U
Converts atmospheric standing pilot gas systems to intermittent pilot. Max capacity of 150kBtuh
Overview
Intermittent Pilot Retrofit Kits save energy by converting atmospheric standing pilot systems to intermittent pilot. Typical applications are gas-fired atmospheric furnaces, boilers and heating appliances.
Features
- Use with natural or LP gas
- Includes gas valve, ignition module, pilot burner hardware, ignition cable, and wiring harness
- Provides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated.
- Ignition trail/delay sequence is repeated until the appliance lights or call for heat is removed..
Product Specifications
- Dimensions (in.)
- 3 15/16 in. high x 5 7/16 in. wide x 2 5/8 in. deep
- Dimensions (mm)
- 100 mm high x 138 mm wide x 67 mm deep
- Includes
- VR8204A2142 valve (1/2 x 1/2; 3.5" WC setting; 150 kBtu/hr at 1" p.d.)
- Electrical Ratings
- 24 Vac
- Frequency
- 60 Hz
- Flame Failure Response Time (sec)
- 2.0 sec
- PrePurge
- 0 or 30 seconds
- Ambient Temperature Range (F)
- -40 F to +165 F
- Ambient Temperature Range (C)
- -40 C to +74 C
- Ignition System Type
- Intermittent Pilot
- Ignition Sequence
- Continuous retry, after trial for ignition, pilot gas shuts off for 5 minutes, then another trial for pilot ignition takes place
- Typical Gas Control
- VR8204, VR8304
- Type of Gas
- Natural or LP
- Flame Sense
- Single Rod or Two Rods
- Ignition Source
- Internal high voltage spark generator
- Ignition Trials To Lockout
- continuous retry
- Lockout Timing
- 15 or 90 seconds
- Ignition Trial Time (sec)
- 15 or 90 seconds
- Maximum Valve Load @ 24 Vac (Amps)
- 1A Pilot, 2A Main @ 24Vac
- Typical Ignition Hardware
- Q345, Q3451