KSCdirect Part #: HON W7100G1001/U
Description: TEMP CONTROLLER, DISCHARGE AIR OR WATER,
MFG Part #: W7100G1001/U
UPC: 85267116572
Supplier: HONEYWELL
Usually ships in 3 days.
You will be notified of any delay and may cancel at that time.

Your Price: $2240.59 / EA

QTY:  
For shipping rates, add item to cart.
* Quantity discounts may be available. Call Kelly Supply at 800-918-8939.
Alternatively, you may e-mail info@kscdirect.com for service.

Details


Commercial Building Controls : Building Management Systems : Controllers (Legacy) : W7100G : W7100G1001/U

20-30 Vac Discharge Air/Water temp. ctrl

Overview

Controls discharge water temperature in reciprocating chiller and cooling tower applications.

Features

  • The W7100G maintains average discharge water temperature by staging on and off compressors, unloaders of water tower fans as required.
  • Provides up to six stages of cooling.
  • Use W7101A for expanding up to 10 cooling stages.
  • Advanced proportional plus integral microprocessor control algorithm minimizes droop.
  • Soft start to minimize compressor cycling during system start up.
  • Adjustable minimum on/off timing and time delay between stages of either 30 or 60 seconds.
  • Reset of discharge water temperature based on either outdoor air or space sensor signal.
  • Use C7170 Sensor for sensing water temperature.
  • LEDs indicate which stages of cooling are energized.
  • Use S963B Potentiometer for remote set point capability.

Product Specifications

Application
Chiller
Dimensions (in.)
8 5/8 in. high x 6 1/2 in. wide x 3 in. deep
Dimensions (mm)
219 mm high x 161 mm wide x 76 mm deep
Comments
4 additional stages of cooling can be added with W7101A
Frequency
50 Hz; 60 Hz
Electrical Connections
1/4 in. quick-connect male terminals
Application Size
0 Heat / 6 Cool
Control System
W7100 family
Output Type
Staged On/Off
Compatible With
W7101 Satellite Expansion Module
Contact Ratings
NO 750 VA inrush @ 120/240 Vac, 75 VA running @ 120/240 Vac; NC 240 VA inrush @ 40 Vac, 30 VA running @ 24 Vac; NO 240 VA inrush @ 24 Vac, 60 VA running @ 24 Vac; NC 75 VA inrush @ 24 Vac, 30 VA running @ 24 Vac
Power Consumption
12 VA at 24 Vac, 50/60 Hz (max).
Voltage
20 to 30 Vac
Operating Temperature Range (F)
-40 F to +150 F
Operating Temperature Range (C)
-40 F to +150 F
Shipping and Storage Temperature Range (F)
-40 F to +150 F
Shipping and Storage Temperature Range (C)
-40 C to +65 C