Distributor
Environmental & Combustion Controls
> Gas Valves for Residential > Universal Controls > VR8345

VR8345Q4563
24 Vac 2-Stage Dual Direct Ignition/Intermittent pilot Gas Valve with
3/4 in. x 3/4 in. inlet/outlet, standard opening and 1.7 in. wc low;
3.5 in. wc high pressure regulator setting
Locate Distributors
Product Specifications Literature and
Documents
Overview
Universal electronic ignition combination gas control for use with
direct spark ignition, hot surface ignition or intermittent pilot
ignition in 24 Vac, gas-fired appliances, with capacities from 30 to
415 cfh.

Features
o Control includes manual valve, two automatic operators, pressure
regulator, pilot adjustment, pilot plug and ignition adapter.
o Replaces virtually any IP, HSI, or DSI gas control.
o For use with natural or manufactured gas or LP gas.
o Includes converter kit to adapt from natural to LP gas.
o Compact size.
o All adjustments and wiring connections accessible from top of
control.
o Four-inch swing radius allows easy rotation into position inside
the tightest furnace vestibules.
o Clearly marked, keyed terminal block allows quick attachment of
wires and IP/DSI/HSI jumper.
o Internal inlet screen blocks contaminants in gas line from entering
valve.
Product Specifications Back To Top
Description 24 Vac Dual Direct Ignition/Intermittent pilot Gas Valve
with 3/4 in. x 3/4 in. inlet/outlet, Slow opening and 3.5 in. wc
pressure regulator setting
Type Single Stage
Ignition Type Direct Ignition
Ignition Type Intermittent Pilot
Type of Gas Natural
Inlet/Outlet Size (in.) 3/4 in. x 3/4 in.
Body Pattern Straight-through
Opening Characteristics (standard, step) Standard
Capacity @ 1 in. p.d. 300,000 BTU/hr; 30,000 BTU/hr minimum
Pressure Ratings (psi) 1/2 psi
Pressure Ratings (kPa) 3.5 kPa
Pressure Regulator Setting (psi) 1.7 in. wc low; 3.5 in. wc high
Pressure Regulator Setting (kPa) 0.48 kPa low; 0.87 kPa high
Pressure Tapping 1/8 in. NPT with plug
Electrical Connections 1/4 in. quick-connect male terminals
Electrical Ratings 24 Vac
Frequency 60 Hz
Temperature Range (F) -40 F to +175 F
Temperature Range (C) -40 C to +79 C
Mounting 0 to 90 degrees in any direction from the upright position of
the gas control knob, including vertically.
Dimensions (in.) 5 3/8 in. high x 4 1/16 in. wide x 2 11/16 in. deep
Dimensions (mm) 135 mm high x 104 mm wide x 69 mm deep
Includes Two 3/4 x 1/2 in. reducer bushings
Includes Natural to LP Conversion Kit
Approvals, American Gas Association IAS AGA Design Certified: File No.
L2025007.
Approvals, Canadian Gas Association CGA Design Certified: File No.
L2025007.
Approvals, Underwriters Laboratories Inc UL Component Recognized.
Tradeline Value Super Tradeline
Literature and other Resources Download
Back To Top
Installation Instructions - (VR8245, VR8345 Universal Electronic
Ignition Gas Controls)
Sell Sheet - (VR8345M VR8345M Universal Electronic Ignition Gas Valve)
Product Data - (VR8345M Control de Gas Universal de Ignicion
Electronica)
Product Data - (VR8345M Universal Electronic Ignition Gas Control)
Installation Instructions - (VR8345M Universal Electronic Ignition Gas
Control)
Download -Submit



Welcome



Category:
SUPPLIER DIRECTORY => HONEYWELL, INC
February 2009
> Gas Valves for Residential > Universal Controls > VR8345
Residential Comfort/Combustion : Combustion Controls : Universal Replacement Parts : Universal Gas Valves : VR8345Q4563/U

Universal 24 Vac, Standard Opening, Two-Stage, Intermittent / Direct Ignition Gas Valve 3/4 x 3/4"

Overview

These valves offers wide-capacity control for almost any IP, HSI or DSI gas-fired appliances.

Product Specifications

Application
Two Stage
Dimensions (in.)
5 3/8 in. high x 4 1/16 in. wide x 2 11/16 in. deep
Dimensions (mm)
135 mm high x 104 mm wide x 69 mm deep
Includes
Two 3/4 x 1/2 in. reducer bushings; Natural to LP Conversion Kit
Item Type
Product
Mounting
0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
Frequency
50 Hz; 60 Hz
Approvals, CSA
CSA International: 112395
Tradeline Value
Universal
Electrical Connections
1/4 in. quick-connect male terminals
Voltage
24 Vac
Operating Temperature Range (F)
-40 F to +175 F
Operating Temperature Range (C)
-40 C to +79 C
Body Pattern
Straight-through
Opening Characteristics
Standard
Pressure Ratings (psi)
1/2 psi
Pressure Ratings (kPa)
3.5 kPa
Inlet/Outlet Size (in.)
3/4 in. x 3/4 in.
Pilot Gas Outlet
Compression fitting for 1/4 in. OD tubing
Pressure Tapping
1/8 in. NPT with plug
Type of Fuel
Natural (LP with included conversion kit)
Capacity (kBtuh)
At 1 in. wc p.d.-- 300,000 BTUh: 30,000 BTUh minimum: 415,000 BTUh maximum Natural Gas
Pressure Regulator
Standard
Pressure Regulator Setpoint (in. wc)
1.7 in. wc low; 3.5 in. wc high
Pressure Regulator Setpoint (kPa)
0.48 kPa low; 0.87 kPa high
Ignition Type
Direct Ignition; Intermittent Pilot

Attributes/Specifications

Category Residential Comfort/Combustion
Manufacturer Approved Supplier
Product Combustion Controls
Style Combustion Controls

Supplemental Files

This item has no supplemental files.