KSCdirect

Product Data

KSCdirect Part #: HON VR8305Q4500/U
Description: 24v 3/4" X 3/4" Hot Surface/Direct Spark Ignition
MFG Part #: VR8305Q4500
UPC: 085267792769
Supplier: Approved Supplier
Usually ships in 8 days.
You will be notified of any delay and may cancel at that time.

Your Price: $322.11 / EA

QTY:  
For shipping rates, add item to cart.
* Quantity discounts may be available. Call Kelly Supply at 800-918-8939.
Alternatively, you may e-mail info@kscdirect.com for service.

Details


Residential Comfort/Combustion : Combustion Controls : Gas Valves, Residential : Direct Burner Ignition : VR8305 : VR8305Q4500/U

24V two stage, dual direct ignition standard opening gas valve

Overview

Combination gas control for use with hot surface/direct spark systems in 24 Vac, gas-fired appliances, with capacities from 30 to 415 cfh.

Features

  • Controls include manual valve, two automatic operators, and pressure regulator.
  • Use with S89C,E,F and S87 series 5 and later.
  • Compact size.
  • Provide two automatic valves.
  • Solenoid-operated first automatic valve opens on thermostat call for heat; closes when call for heat ends.
  • Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted.
  • Meet codes requiring dual safety shut-off.
  • All adjustments, wiring connections and pilot outlet are accessible from top of control.
  • Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure.
  • ON-OFF lighting sequence.
  • Natural to LP and LP to Natural conversion kits available for standard and slow opening gas valves.

Product Specifications

Application
Two Stage
Dimensions (in.)
5 3/8 in. high x 2 11/16 in. wide x 4 1/16 in. deep
Dimensions (mm)
135 mm high x 69 mm wide x 104 mm deep
Includes
Two 3/4 x 1/2 in. reducer bushings; Natural to LP Conversion Kit
Item Type
Product
Mounting
0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
Frequency
60 Hz
Approvals, Underwriters Laboratories Inc.
UL Component Recognized.
Approvals, CSA
CSA International: 112395
Electrical Connections
1/4 in. quick-connect male terminals
Voltage
24 Vac
Operating Temperature Range (F)
-40 F to +175 F
Operating Temperature Range (C)
-40 C to +79 C
Approvals, Canadian Gas Association
Body Pattern
Straight-through
Opening Characteristics
Standard
Pressure Ratings (psi)
1/2 psi
Pressure Ratings (kPa)
3.5 kPa
Inlet/Outlet Size (in.)
3/4 in. x 3/4 in.
Pressure Tapping
1/8 in. NPT with plug
Approvals, American Gas Association
Type of Fuel
Natural
Capacity (kBtuh)
At 1 in. wc p.d.-- 300,000 BTUh: 30,000 BTUh minimum
Pressure Regulator Setpoint (in. wc)
1.7 in. wc low; 3.5 in. wc high
Pressure Regulator Setpoint (kPa)
0.48 kPa low; 0.87 kPa high
Ignition Type
Direct Ignition
Anticipator Setting
0.62 A

Attributes/Specifications

Category Residential Comfort/Combustion
Manufacturer Approved Supplier
Product Combustion Controls
Style Combustion Controls