Residential Comfort/Combustion : Combustion Controls : Gas Valves, Residential : Intermittent Pilot : VR8204 : VR8204H1006/U
Single Stage, 24 Vac, Slow Opening, Intermittent Pilot Gas Valve. 1/2 x 1/2". Set 3.5" WC
Overview
Gas valves for use in 24 Vac, gas-fired, intermittent pilot appliances with capacities from 20 to 200 cfh.
Features
- Gas valves include manual valve, two automatic operators, servo pressure regulator and pilot adjustment.
- Use with S86F,H; S8600F,H and S8610 Control Modules.
- Compact size.
- Provide two automatic valves.
- Solenoid operated first automatic valve opens on thermostat call for heat; closes when call for heat ends.
- Diaphragm operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted.
- Meet codes requiring dual safety shutoff.
- Natural to LP and LP to Natural conversion kits available for standard and slow opening gas valves.
- All adjustments and wiring connections are accessible from top of control.
- ON-OFF lighting sequence.
- Compatible with ECO connector.
Product Specifications
- Application
- Single Stage
- Dimensions (in.)
- 4 5/8 in. high x 4 1/8 in. wide x 2 11/16 in. deep
- Dimensions (mm)
- 117 mm high x 104 mm wide x 69 mm deep
- Item Type
- Product
- Mounting
- 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
- Frequency
- 60 Hz
- Approvals, Underwriters Laboratories Inc.
- UL Component Recognized MCCZ2.MH5323
- Approvals, CSA
- CSA International: 112395
- Electrical Connections
- 1/4 in. quick-connect male terminals
- Voltage
- 24 Vac
- Operating Temperature Range (F)
- 0 F to 175 F
- Operating Temperature Range (C)
- -18 C to +79 C
- Approvals, Canadian Gas Association
-
- Body Pattern
- Straight-through
- Opening Characteristics
- Slow
- Pressure Ratings (psi)
- 1/2 psi
- Pressure Ratings (kPa)
- 3.5 kPa
- Inlet/Outlet Size (in.)
- 1/2 in. x 1/2 in.
- Pilot Gas Outlet
- Compression fitting for 1/4 in. OD tubing
- Pressure Tapping
- 1/8 in. NPT with plug
- Approvals, American Gas Association
-
- Type of Fuel
- Natural
- Capacity (kBtuh)
- At 1 in. wc p.d.-- 150,000 BTUh: 20,000 BTUh minimum: 200,000 BTUh maximum Natural Gas
- Approvals, Australian Gas Association
- 4752
- Pressure Regulator
- Slow
- Pressure Regulator Setpoint (in. wc)
- 3.5 in. wc
- Pressure Regulator Setpoint (kPa)
- 0.87 kPa
- Ignition Type
- Intermittent Pilot
- Anticipator Setting
-