THERMOSTAT PROG A+F 12VDC R
Residential Comfort/Combustion : Thermostats : Programmable : Master/Slave System Units : TH115-AF-12VDC/U
Low Volt Programmable Master Thermostat for Floor heating over 15 A
Overview
This system is specially designed for large floor heating applications exceeding 15A.
Features
- Here's how it works
- A floor heating area exceeding 15A is separated into zones, with a linked unit responsible for heating each zone.
- All linked units are controlled by a master thermostat responsible for settings/programming of the entire floor.
- No settings dial. Settings controlled by master means units can be installed anywhere
- ON/STANBY switch enables unit's heating area to be shut down independently of other heating areas
- Built-in GFCI/EGFPD with test light. No need to buy separate safety cutoff.
Product Specifications
- Application
- Master unit for radiant floor
- Dimensions (in.)
- 4.9 in. X 2.8 in. X 0.9 in.
- Dimensions (mm)
- 124 mm X 70 mm X 23 mm
- Includes
- Aube AC112-01 15-feet / 4.6-m floor sensor
- Used With
- Aube CT230-120GA, CT230-120GB, CT230-240GA or CT230-240GB Floor Heating Slave Units; Aube AC112-01 North American Floor Sensor (15-feet / 4.6-m)
- Comments
- With Backlit Display; works with up to 10 CT230 slave units
- Item Type
- Product
- Mounting
- Vertical
- Electrical Ratings
- Maximum Load: 75 mA @ 12 VDC
- Approvals, CSA
- Approved
- Electrical Connections
- 6 in. (150 mm) tinned copper lead wires
- Supply Voltage
- 75 mA @ 12 VDC
- Switch Positions (System)
- AF (ambient + floor)/ F (floor only); Display format: F/12 h or C/24h; Early Start function: Enabled or Disabled
- Operating Temperature Range (F)
- 32 F to 122 F
- Operating Temperature Range (C)
- 0 C to 50 C
- Sensor Element
- Thermistor
- Color
- White
- Ambient Temperature Range (F)
- 32 F to 140 F
- Ambient Temperature Range (C)
- 0 C to 60 C
- Switch Type
- Relay
- Programmability
- 7-Day Program
- Power Method
- Hardwired
- Temperature Control Mode Selections
- Ambient Air; Floor
- Setting Temperature Range (F)
- Ambient: 40 F to 86 F; Floor limit: 40 F to 104
- Setting Temperature Range (C)
- Ambient: 5 C to 30 C; Floor limit: 5 C to 40 C
- Parts Needed for Operation (not included) - Non-Zoned System
- Must be linked to at least 1 slave unit (CT-230-XXXXXX)