THERMOSTAT N-PROG A+F 24V DIGITAL
Residential Comfort/Combustion : Thermostats : Non-Programmable : TH114-AF : TH114-AF-024T/U
Low volt electric heating (ambient and floor) manual thermostat
Overview
The TH114 Series delivers the features that matter most in a non-programmable thermostat: an easy-to-read backlit display, slim contemporary design and precise temperature control.
Features
- Three choices of temperature control in a single thermostat (Ambient, Floor, or Ambient with Floor temperature limits)
- 5 mA ground fault circuit interrupter (GFCI) on GA models
- 15 mA equipment ground fault protection devices (EGFPD) on GB models
- GFCI and EGFPD test light verifies safety control is functioning properly and alerts if a leak is detected
- Advanced temperature control ensures total comfort by minimizing temperature swings
- ON/STANDBY switch enables thermostat shutdown at the end of heating season for added security
- On-screen heating power indicator gives at-a-glance verification of power being used
- Backlit display
- Battery-free
Product Specifications
- Application
- Radiant floor
- Dimensions (in.)
- 4.9 in. X 2.8 in. X 0.9 in.
- Dimensions (mm)
- 124 mm X 70 mm X 23 mm
- Includes
- Aube AC112-01 North American Sensor, 15 feet (4.6 m)
- Used With
- Aube RC840/RC840T Series Electromechanical Relays; Aube AC112-01 North American Sensor, 15 feet (4.6 m)
- Comments
- With Backlight & On/Standby Switch
- Item Type
- Product
- Mounting
- Vertical
- Electrical Ratings
- Max. 0.5 A @ 24 VAC
- Supply Voltage
- 24 Vac
- Switch Positions (System)
- AF (ambient + floor)/ F (floor only)
- Operating Temperature Range (F)
- 32 F to 122 F
- Operating Temperature Range (C)
- 0 C to 50 C
- Sensor Element
- Thermistor
- Accuracy (F)
- 0.9 F
- Accuracy (C)
- 0.5 C
- Differential Temperature (F)
- 1 F
- Differential Temperature (C)
- 0.5 C
- Color
- White
- Ambient Temperature Range (F)
- AF mode: 32 F to 122 F; F mode: 32 F to 140 F
- Ambient Temperature Range (C)
- AF mode: 0 C to 50 C; F mode: 0 C to 60 C
- Switch Type
- External electromechanical relay
- Power Method
- Hardwired
- Terminal Designations
- R, C, W
- Setting Temperature Range (F)
- 40 F to 86 F room temperature; 40 F to 104 F floor temperature
- Setting Temperature Range (C)
- 5 C to 30 C room temperature; 5 C to 40 C floor temperature
- Parts Needed for Operation (not included)
- External electromechanical relay