Distributor
Environmental & Combustion Controls
> S9200
S9200U1000
Universal Hot Surface Ignition Integrated Furnace Control. Controls a
standard induction-type circulating fan motor.
Locate Distributors
Product Specifications Literature and
Documents
Overview
The S9200U1000 can be used with conventional thermostats as well as
the EnviraCOM(TM) enabled VisionPRO IAQ and FocusPRO. The S9200U1000
Universal Integrated Furnace Control is intended for residential
natural or liquid propane fueled furnaces only. The S9200U1000
EnviraCOM(TM) communications capability allows its use in twinning
applications and enables communication with local and remote
diagnostic devices such as the QuickLook hand held device
(QuickLook(TM) 72), EnviraLINK web-based application and the W8735D
Telephone Access Module (TAM).
Features
o Main burner ignition using a 120V hot surface igniter.
o Flame rectification circuit to monitor flame presence.
o Monitoring of system pressure switch, high temperature limit, and
rollout functions.
o Appliance operation/safety requirements controlled via
microprocessor.
o Control of a standard induction-type circulating fan motor (based
on appliance requirements), in response to a conventional low voltage
or EnviraCOM(TM) thermostat.
o LED system status, performance and diagnostic indication.
o Wire harnesses provided for simple replacement of most IFCs and
integration with most heating and cooling appliances.
o Twinning capability
o EnviraCOM(TM) communication capability to enable local and/or
remote system status, diagnostics, troubleshooting, and HVAC system
control.
Product Specifications Back To Top
Description Universal single stage heating & cooling
Line Voltage 120Vac (97-132 Vac)
Low Voltage 24V (18-30Vac)
Frequency 60 Hz
Operating Temperature (F) -40 F to +175 F
Operating Temperature (C) -40 C to +79 C
Operating Humidity Range (% RH) 0% to 95% non-condensing
Igniter Current 1.0A resistive @ 95Vac output
Thermostat Anticipator Setting (Stage 1 only) 100mA
PrePurge 30 seconds
HSI Warmup Time 17/27 or 30/30 seconds
Trial For Ignition 4, 6, or 8 seconds
PostPurge 15 seconds
Interpurge 60 seconds
Ignition Trials Three, two tries if flame is not sensed
Flame Failure Response Time 2 Seconds max @ 1A
Number of LEDs 3
Heat On Fan Delay 30 or 60 seconds
Heat Off Fan Delay 60, 90, 120, or 180 Seconds
Cool Fan On Delay 5 seconds
Cool Fan Off Delay 0 or 60 seconds
Gas Control Used With Any 24Vac redundant, direct ignition gas control
rated at 1.5A or less. Honeywell VR8205 recommended.
Cooling Contactor Used With Any 24Vac contactor rated at 1.0A or less
Induced Draft Blower Load 2.2FLA / 25LRA max @120Vac
Ciculator Load 14.5FLA / 25LRA max @120Vac
Type of Fan Used With Standard Induction-Type Circulating Fan
Literature and other Resources Download
Back To Top
Sell Sheet - (S9200U1000 Universal Integrated Furnance Control (UIFC))
Sell Sheet - (S9200U1000 Universal Integrated Furnance Control (UIFC)
- French)
Installation Instructions - (S9200U1000 Universal Hot Surface Ignition
Integrated Furnace Control (UIFC))
Addendum - (S9200U1000 Universal Hot Surface Ignition Integrated
Furnace Control)
Poster - (S9200U1000U S9200U1000& Universal Integrated Furnance
Control (UIFC))
counter mat insert - (S9200U1000 S9200U1000 Universal Integrated
Furnance Control)
Cross Reference - (S9200U1000 S9200U1000 Universal Integrated Furnance
Control Cross-Reference Guide)
Technicians Quick Reference Guide - (S9200U1000 Universal Hot Surface
Ignition Integrated Furnace Control (UIFC))
Download -Submit
Welcome
Category: SUPPLIER DIRECTORY => HONEYWELL, INC
February 2009
> S9200
Residential Comfort/Combustion : Combustion Controls : Universal Replacement Parts : Universal Integrated Furnace Control : S9200U1000/U
Universal Hot Surface Ignition Integrated Furnace Control
Overview
Universal Integrated Furnace Control offers universal compatibility and diagnostics. It replaces a large number of furnace control models in single-stage warm air furnaces. Uses 120Vac hot surface igniter. Includes instructions and special wire harnesses for easy replacement.
Features
- Cross reference and wire harnesses provided for simple replacement over 195 existing furnace controls.
- Main burner ignition using a 120V hot surface igniter.
- Flame rectification circuit to monitor flame presence.
- Monitoring of system pressure switch, high temperature limit, and rollout functions.
- Appliance operation/safety requirements controlled via microprocessor.
- Controls circulating fan motor based on appliance requirements, in response to a conventional low voltage thermostat.
- LED system status, performance and diagnostic indication.
- Twinning capability
Product Specifications
- Application
- Single stage warm air furnaces
- Frequency
- 60 Hz
- Operating Humidity Range (% RH)
- 0% to 95% non-condensing
- Operating Temperature Range (F)
- -40 F to +175 F
- Operating Temperature Range (C)
- -40 C to +79 C
- Flame Failure Response Time (sec)
- 2 Seconds max @ 1A
- PrePurge
- 30 seconds
- PostPurge
- 15 seconds
- Cool Fan On Delay
- 5 seconds
- Cool Fan Off Delay
- 0 or 60 seconds
- Line Voltage
- 120 Vac (97-132 Vac)
- Low Voltage
- 24V (18-30 Vac)
- Igniter Current
- 5 A resistive @ 120VAC
- Thermostat Anticipator Setting
- (Stage 1 only) 100mA
- HSI Warmup Time
- 17/27 or 30/30 seconds
- Trial For Ignition
- 4, 6, or 8 seconds
- Interpurge
- 60 seconds
- Ignition Trials
- Three, two tries if flame is not sensed
- Number of LEDs
- 3
- Heat On Fan Delay
- 30 or 60 seconds
- Heat Off Fan Delay
- 60, 90, 120, or 180 Seconds
- Gas Control Used With
- Any 24Vac redundant, direct ignition gas control rated at 1.5A or less. Honeywell VR8205 recommended.
- Cooling Contactor Used With
- Any 24Vac contactor rated at 1.0A or less
- Induced Draft Blower Load
- 2.2FLA / 25LRA max @120Vac
- Ciculator Load
- 14.5FLA / 25LRA max @120Vac
- Type of Fan Used With
- Standard Induction-Type Circulating Fan