Distributor
Environmental & Combustion Controls
> Primary Controls > R8184G
R8184G4082
Protectorelay Oil Burner Control with 45 seconds lock out timing
Locate Distributors
Product Specifications Literature and
Documents
Overview
Provides automatic, nonrecycling control of an intermittent ignition
oil burner system.
Features
o Controls oil burner, oil valve (if desired) and the ignition
transformer in response to a call for heat.
o Solid state flame sensing circuit.
o LED on terminal strip indicates system lockout.
o Remote lockout indication available on some models.
o Enclosed safety switch with external reset button.
o Manual trip lever opens safety switch for system maintenance.
o Mounts on standard 4 x 4 in. junction box; select models may be
mounted directly on burner housing.
o C554A Cadmium Sulfide Flame Detector and 24 Vac thermostat
required.
Product Specifications Back To Top
Description Protectorelay Oil Burner Control with 45 seconds lock out
timing
Ignition Type Intermittent
Timing, Safety Switch 45 sec.
Mounting Bracket For mounting on a standard 4 in. X 4 in. junction box
or direct mounting on burner housing.
Electrical Rating; Contacts (full load) 7.4 A @ 120 Vac; 3.7 a @ 240
Vac
Electrical Rating; Contacts (locked rotor) 44.4 A @ 120 Vac; 22.2 A @
240 Vac
Alarm Load Ratings (pilot duty) 75 VA @ 120/240 Vac, 50-60 Hz; 25 VA @
24V, 50-60 Hz
Alarm Load Ratings (resistive) 1.5 A @ 120/240V, 50-60Hz; 3 A @ 24 V,
50-60 Hz
Dimensions (in.) 4 3/8 in. high x 4 1/8 in. wide x 2 1/2 in. deep
Dimensions (mm) 111 mm high x 104 mm wide x 64 mm deep
Temperature Range (F) -40 F to +130 F
Temperature Range (C) -40 C to +54 C
Approvals, Underwriters Laboratories Inc UL Component Recognized; File
no. MP268, Vol. 35 Sec. 1,3
Approvals, Canadian Standards Association CSA Certified; File no.
LR95329-1
Includes Alarm
Comments With LED for lockout indication, and manual trip lever on
safety switch to assure burner shutdown during servicing. Includes
remote alarm dry contacts.
Tradeline Value Tradeline
Literature and other Resources Download
Back To Top
Sell Sheet - (R8184 R8184 Protectorelay Oil Primary Controls)
Installation Instructions - (R4184D, R8184G, R8184M, R8184N, R8184P
Protectorelay Oil Primary Controls)
Installation Instructions - (R4184D, R8184G, R8184M, R8184N, R8184P
Regulateurs Primaires Protectorelay-FRENCH)
Addendum - (R8184G Protectorelay Oil Primary (Addendum to 69-0617-1))
Installation Instructions - (R8184G Protectorelay Oil Primary)
Installation Instructions - (R8184G4033, R8184G4058 Protectorelay Oil
Primary-Tradeline- English/French)
Installation Instructions - (R8184M1051 Protectorelay Oil Burner
Control- TRADELINE)
Product Data - (R8184M Protectorelay Oil Burner Control)
Installation Instructions - (R8184G Protectorelay Oil Primary-
English/French)
Installation Instructions - (R8184G Protectorelay Oil Primary)
Installation Instructions - (R8184G Protectorelay Oil Burner Control -
English/French)
Download -Submit
Welcome
Category: SUPPLIER DIRECTORY => HONEYWELL, INC
February 2009
> Primary Controls > R8184G
Residential Comfort/Combustion : Combustion Controls : Oil Burner Controls : Oil Primaries : R8184G : R8184G4082/U
Protectorelay Oil Burner Control with 45 second safety timing and alarm outputs
Overview
Provides automatic, nonrecycling control of an intermittent ignition oil burner system.
Features
- Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat.
- Solid state flame sensing circuit.
- LED on terminal strip indicates system lockout (available on some models).
- Remote lockout indication (available on some models).
- Enclosed safety switch with external reset button.
- Manual trip lever opens safety switch for system maintenance.
- Mounts on standard 4 x 4 in. junction box; select models may be mounted directly on burner housing.
- C554A Cadmium Sulfide Flame Detector and 24 Vac thermostat required..
Product Specifications
- Dimensions (in.)
- 4 3/8 in. high x 4 1/8 in. wide x 2 1/2 in. deep
- Dimensions (mm)
- 111 mm high x 104 mm wide x 64 mm deep
- Temperature Range (F)
- -40 F to +130 F
- Temperature Range (C)
- -40 C to +54 C
- Includes
- Alarm
- Comments
- With LED for lockout indication, and manual trip lever on safety switch to assure burner shutdown during servicing. Includes remote alarm dry contacts.
- Item Type
- Product
- Mounting
- For mounting on a standard 4 in. X 4 in. junction box or direct mounting on burner housing.
- Approvals, Underwriters Laboratories Inc.
- UL Component Recognized; File no. MP268, Vol. 35 Sec. 1,3
- Approvals, CSA
- CSA Certified; File no. LR95329-1
- Tradeline Value
- Tradeline
- Ignition Type
- Intermittent
- Timing, Safety Switch
- 45 sec.
- Electrical Ratings, Contacts (full load)
- 7.4 A @ 120 Vac; 3.7 a @ 240 Vac
- Electrical Ratings, Contacts (locked rotor)
- 44.4 A @ 120 Vac; 22.2 A @ 240 Vac
- Alarm Load Ratings (pilot duty)
- 75 VA @ 120/240 Vac, 50-60 Hz; 25 VA @ 24V, 50-60 Hz
- Alarm Load Ratings (resistive)
- 1.5 A @ 120/240V, 50-60Hz; 3 A @ 24 V, 50-60 Hz