KSCdirect

Product Data

KSCdirect Part #: HON R8184G4009/U
Description: Cad Cell Relay (45 Sec)Intermittent,120v
MFG Part #: R8184G4009
UPC: 85267990127
Supplier: Approved Supplier
Usually ships in 8 days.
You will be notified of any delay and may cancel at that time.

Your Price: $181.15 / EA

QTY:  
For shipping rates, add item to cart.
* Quantity discounts may be available. Call Kelly Supply at 800-918-8939.
Alternatively, you may e-mail info@kscdirect.com for service.

Details


Residential Comfort/Combustion : Combustion Controls : Oil Burner Controls : Oil Primaries : R8184G : R8184G4009/U

Protectorelay Oil Burner Control with 45 second safety timing, alarm outputs, and manual safety switch

Overview

Provides automatic, nonrecycling control of an intermittent ignition oil burner system.

Features

  • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat.
  • Solid state flame sensing circuit.
  • LED on terminal strip indicates system lockout (available on some models).
  • Remote lockout indication (available on some models).
  • Enclosed safety switch with external reset button.
  • Manual trip lever opens safety switch for system maintenance.
  • Mounts on standard 4 x 4 in. junction box; select models may be mounted directly on burner housing.
  • C554A Cadmium Sulfide Flame Detector and 24 Vac thermostat required..

Product Specifications

Dimensions (in.)
4 3/8 in. high x 4 1/8 in. wide x 2 1/2 in. deep
Dimensions (mm)
111 mm high x 104 mm wide x 64 mm deep
Temperature Range (F)
-40 F to +130 F
Temperature Range (C)
-40 C to +54 C
Comments
With LED for lockout indication, and manual trip lever on safety switch to assure burner shutdown during servicing.
Item Type
Product
Mounting
For mounting on a standard 4 in. X 4 in. junction box or direct mounting on burner housing.
Approvals, Underwriters Laboratories Inc.
UL Component Recognized; File no. MP268, Vol. 35 Sec. 1,3
Approvals, CSA
CSA Certified; File no. LR95329-1
Tradeline Value
Tradeline
Ignition Type
Intermittent
Timing, Safety Switch
45 sec.
Electrical Ratings, Contacts (full load)
7.4 A @ 120 Vac; 3.7 a @ 240 Vac
Electrical Ratings, Contacts (locked rotor)
44.4 A @ 120 Vac; 22.2 A @ 240 Vac
Alarm Load Ratings (pilot duty)
75 VA @ 120/240 Vac, 50-60 Hz; 25 VA @ 24V, 50-60 Hz
Alarm Load Ratings (resistive)
1.5 A @ 120/240V, 50-60Hz; 3 A @ 24 V, 50-60 Hz

Attributes/Specifications

Category Residential Comfort/Combustion
Manufacturer Approved Supplier
Product Combustion Controls
Style Combustion Controls

Supplemental Files

This item has no supplemental files.