KSCdirect

Product Data

KSCdirect Part #: HON R8182H1070/U
Description: Triple Aquastat Relay, Intermittent Ign. 45 Se
MFG Part #: R8182H1070
UPC: 85267078399
Supplier: Approved Supplier
Please use Live Chat or call 800-918-8939 for exact lead time.

Your Price: $1263.48 / EA

QTY:  
For shipping rates, add item to cart.
* Quantity discounts may be available. Call Kelly Supply at 800-918-8939.
Alternatively, you may e-mail info@kscdirect.com for service.

Details


Residential Comfort/Combustion : Combustion Controls : Aquastats : Aquastats Gas - Multifunction : R8182 : R8182H1070/U

Combination Protectorelay and Hydronic Heating Control. Junction box mount

Overview

Immersion type Aquastat controller and oil burner primary control provides high limit and low limit/circulator control for oil-fired hydronic heating systems.

Features

  • Use in intermittent ignition applications.
  • Capable of zone control with zone valves.
  • Circulator zone control with ZC and ZR terminals on R8182D,E,H,J. 8*Flame failure during the running cycle results in a 45 second attempt to restart.
  • If unsuccessful, safety shutoff occurs, requiring manual reset before burner can be restarted.
  • R8182D,E,F mount directly on burner; R8182H,J mount on 4 x 4 in. junction box and include 5 ft (1.5 m) armored capillary with remote sensor.
  • C554A Cadmium Sulfide Flame Detector and a 24 Vac thermostat required.

Product Specifications

Hazmat Information
UN1294 Toluene
Dimensions (in.)
7 1/8 in. high x 5 1/4 in. wide x 3 7/16 in. deep.
Dimensions (mm)
181 mm high x 133 mm wide x 87 mm deep.
Maximum Safe Operating Pressure (psi)
200 psi on immersion well; 100 psi direct immersion.
Maximum Safe Operating Pressure (kPa)
1378 kPa on immersion well; 90 kPa direct immersion.
Temperature Range (F)
Maximum--250 F at element
Temperature Range (C)
Maximum--121 C at element
Includes
Auxiliary ZC and ZR terminals may be used to provide circulator zone control through an R845A Switching Relay. Heat-conductive compound and horizontal case.
Mounting
Junction box mount
Frequency
60 Hz
Approvals, Underwriters Laboratories Inc.
UL Listed: File No. listed: MP268, Vol. 3,4 (R8182D,E,F), Vol. 37 (R8182H,J), Sec. 1.
Approvals, CSA
Certified: File No. LR95329-1
Tradeline Value
Tradeline
Operating Humidity Range (% RH)
0 to 95% RH, non-condensing
Power Consumption
9 W
Voltage
120 Vac
Operating Temperature Range (F)
High Limit-- 130 F to 240 F; Low Limit-- 110 F to 220 F
Operating Temperature Range (C)
High Limit-- 54 C to 116 C; Low Limit-- 43 C to 104 C
Differential Temperature (F)
High limit: 10 F fixed; Low limit/circulator: 10 F to 25 F adj.
Timing
Safety Switch-- 45 sec
Anticipator Setting
0.2 A
Insulation Depth (in.)
1 1/2 in.
Insulation Depth (mm)
38 mm
Electrical Ratings, Ignition
360 VA
Electrical Ratings, Burner
At Full Load-- 4.4 A @ 120 Vac; At Locked Rotor-- 26.4 A @ 120 Vac

Attributes/Specifications

Category Residential Comfort/Combustion
Manufacturer Approved Supplier
Product Combustion Controls
Style Combustion Controls

Supplemental Files

This item has no supplemental files.