Product Specifications | |
|
Description | Cartridge Globe Valve Actuator |
Fail Safe Mode | Spring Return, operator retracts up |
Supply Voltage | 24 Vac +20%, -15% |
Number of Internal Auxiliary Switch | 0 |
Medium Temperature (F) | 266 F Maximum |
Medium Temperature (C) | 130 C Maximum |
Mounting | Threads onto V58XX valve bonnet |
Spring Return Timing (Nominal (sec)) | 10 sec |
Timing, Nominal Driving @ 60 Hz (sec) | 50 sec |
Dimensions (in.) | 3 3/16 in. high x 4 1/4 in. wide x 5 in. deep |
Dimensions (mm) | 81 mm high x 108 mm wide x 126 mm deep |
Electrical Protection | Class I Insulation (24 Vac) |
Materials | Low Maintenance Plastic Housing |
Power Consumption (Driving) | 10 VA |
Electrical Connections | Screw terminals |
Cable Entry | Threaded conduit connector |
Temperature Range, Ambient (F) | 32 F to 122 F |
Temperature Range, Ambient (C) | 0 C to 50 C |
Temperature Range, Storage (F) | -40 F to +158 F |
Temperature Range, Storage (C) | -40 C to +70 C |
Operating Humidity Range (% RH) | 5 to 95% RH |
Ingress Protection Rating | IP54 |
Approvals, Underwriters Laboratories Inc | UL94-5V |
Used With | 1/2 inch and 3/4 inch V58XX Cartridge Globe Valves |
|
Keywords: HONEYW HON M6435A1004 M6435A1004 HONEYWELL, INC 085267244664 VALVE ACTUATOR, SPRING RETURN, FLOATING CONTROL OF 1/2 AND 3/4 V58 CAR...
Category: [0] => SUPPLIER DIRECTORY => HONEYWELL, INC => HONEYWELL THERMOSTATS, ELECTRIC, VALVES, PARTS, ETC SECTION 31
[1] => SUPPLIER DIRECTORY => HONEYWELL, INC => HONEYWELL REPLACEMENT PARTS => Honeywell Direct Coupled => SUPPLIER DIRECTORY => HONEYWELL, INC => HONEYWELL THERMOSTATS, ELECTRIC, VALVES, PARTS, ETC SECTION 31
Commercial Building Controls : Valves and Valve Actuators : Valve Actuators : M6435/M7435 : M6435A1004
Spring Ret Float Cart.Globe Vlv Actuator
Overview
Cartridge Globe Valve Spring Return Actuators are small electric actuators for individual room control that provide floating or modulating control of V5852, V5862 two-way or V5853, V5863 three-way valves.
Features
- Stem actuator retracts up on power failure. Fail safe mode depends on valve seat rest position.
- Suitable for Excel/IRC system or other controllers providing specified signals.
- Magnetic coupling for torque limitation independent of voltage supply and self-adjustment of the close-off port.
- No mounting tools required.
- Compact size allows installation in limited space of fan coil units, induction units, and small reheaters or recoolers.
- Visual position indication (red disk).
Product Specifications
- Application
- HVAC
- Dimensions (in.)
- 3 3/16 in. high x 4 1/4 in. wide x 5 in. deep
- Dimensions (mm)
- 81 mm high x 108 mm wide x 126 mm deep
- Includes
- 1/2 in. conduit hub
- Used With
- 1/2 inch and 3/4 inch V58XX Globe Valves
- Weight (lb)
- 1.1 lb
- Weight (kg)
- 0.5 kg
- Materials
- Low Maintenance Plastic Housing
- Item Type
- Product
- Mounting
- Threads onto V58XX valve bonnet
- Frequency
- 50 Hz; 60 Hz
- Approvals, Underwriters Laboratories Inc.
- Flammability Rating UL94V-5V
- Electrical Connections
- Screw terminals
- Operating Humidity Range (% RH)
- 5 to 95% RH
- Supply Voltage
- 24 Vac +20%, -15%
- Power Consumption
- Driving-- 10 VA
- Shipping and Storage Temperature Range (F)
- -40 F to +158 F
- Shipping and Storage Temperature Range (C)
- -40 C to +70 C
- Ambient Temperature Range (F)
- 32 F to 122 F
- Ambient Temperature Range (C)
- 0 C to 50 C
- Environmental, Electrical or Ingress Protection Rating
- IP54,Class I Insulation (24 Vac)
- Internal Auxiliary Switch
- 0
- Fluid Temperature (C)
- 130 C Maximum
- Fluid Temperature (F)
- 266 F Maximum
- Actuator Type
- Valve
- Control Signal
- SPDT; Two position; Floating
- Fail Safe Mode
- (Normally open for 1/2 in. and 3/4 in. V5852 and V5862. Normally closed for all other V58XX valves.); Spring Return, operator retracts up
- Torque Rating (lb-in.)
- 40.5 lbf
- Torque Rating (Nm)
- 180 N
- Spring Return Torque/Force (lb-in., lbf)
- 40.5 lbf
- Spring Return Torque/Force (Nm, N)
- 180 N
- Switches
- No
- Stroke (in.)
- 1/4 in.
- Stroke (mm)
- 6 mm
- Cable
- Threaded conduit connector
- Timing, Nominal
- Driving @ 60 Hz-- 50 sec
- Spring Return Timing
- Nominal-- 10 sec
- Feedback
- No
- Manual operation
- None (use valve dust cap)
- Spring Return Direction
- Stem up