Product Specifications | |
|
Description | Fan and Limit Controller with 125 F fan on and 100 F fan off stops, 200 F high limit stop and 11 1/2 in. insertion |
Application | Forced warm air heating systems |
High Limit Temperature Range (F) | 100 F to 250 F |
High Limit Temperature Range (C) | 38 C to 121 C |
Element Insertion Length (in.) | 11 1/2 in. |
Element Insertion Length (mm) | 292 mm |
Fan-on Range (F) | 65 F to 215 F |
Fan-on Range (C) | 18 C to 102 C |
Fan-off Range (F) | 50 F to 200 F |
Fan-off Range (C) | 10 C to 93 C |
Switching Action | Fan switch makes and high limit switch breaks on temperature rise. |
Electrical Rating Fan (AFL) | 14 A @ 120 Vac |
Electrical Rating Fan (AFL) | 7 A @ 240 Vac |
Electrical Rating Fan (ALR) | 84 A @ 120 Vac |
Electrical Rating Fan (ALR) | 42 A @ 240 Vac |
Electrical Rating Limit (AFL) | 4 A @ 240 Vac |
Electrical Rating Limit (AFL) | 8 A @ 120 Vac |
Electrical Rating Limit (ALR) | 24 A @ 240 Vac |
Electrical Rating Limit (ALR) | 48 A @ 120 Vac |
Pilot Duty Ratings | 2 A @ 24 Vac |
Pilot Duty Ratings | 0.25 A @ 0.25 to 12 Vdc |
Operating Temperature Range (F) | -40 F to +190 F |
Operating Temperature Range (C) | -40 C to +88 C |
Differential Temperature (F) | High limit 25 F |
Differential Temperature (C) | High limit 14 C |
Maximum Ambient Temperature (F) | Switch: 190F; Sensing Element: 350 F |
Maximum Ambient Temperature (C) | Switch: 88 C; Sensing Element: 177 C |
Dimensions (in.) | 4 9/32 in. high x 3 in. wide x 1 19/32 in. deep excluding element |
Dimensions (mm) | 109 mm high x 76 mm wide x 40 mm deep excluding element |
Approvals, Underwriters Laboratories Inc | Listed File MP466, Guide MBPR |
Approvals, Canadian Standards Association | Certified: File No. LR1622 |
Comments | Turns fan on and off according to plenum temperature. With helical bimetal sensing element. High limit stop set at 200F (93 C). With manual fan switch. Small case and cover. Replaces L4064A,B,E. |
|
Keywords: HONEYW HON L4064B2210 L4064B2210 HONEYWELL, INC 085267000192 TRADELINE. 11-1/2 IN INSERTION; 3/4 IN TUBE; 200F LIMIT STOP, ZINC PLATE...
Category: [0] => SUPPLIER DIRECTORY => HONEYWELL, INC => HONEYWELL THERMOSTATS, ELECTRIC, VALVES, PARTS, ETC SECTION 33
[1] => SUPPLIER DIRECTORY => HONEYWELL, INC => HONEYWELL REPLACEMENT PARTS => Honeywell L4064 => SUPPLIER DIRECTORY => HONEYWELL, INC => HONEYWELL THERMOSTATS, ELECTRIC, VALVES, PARTS, ETC SECTION 33
Residential Comfort/Combustion : Combustion Controls : Fan and Limit Controls : L4064 : L4064B2210/U
Fan and limit controller. 11 1/2 inch insert
Overview
Controls high limit and fan motors in forced air heating systems.
Features
- Three wiring terminal options available for easy installation.
- Push-in receptacles for stripped wire.
- Female receptacles for 1/4 inch male flag connectors.
- Auxiliary screw terminals.
- Field adjustable fan and high limit settings.
- L4064B,W, and R models have a manual fan switch that overrides the fan control to keep the fan running continuously.
- TRADELINE models with mounting adapters for easy installation and strain relief bushings to protect wiring from field abuse..
Product Specifications
- Application
- Forced warm air heating systems
- Dimensions (in.)
- 4 9/32 in. high x 3 in. wide x 1 19/32 in. deep excluding element
- Dimensions (mm)
- 109 mm high x 76 mm wide x 40 mm deep excluding element
- Comments
- Turns fan on and off according to plenum temperature via helical bimetal sensing element. High limit stop set at 200F (93 C). Breakaway Jumper included. Includes manual and automatic fan on/off settings. Replaces L4064A,B,E.
- Mounting
- Surface or universal mounting bracket available (50077438-001/U)
- Electrical Ratings
- Fan- (AFL)-- 14 A @ 120 Vac: 7 A @ 240 Vac; Fan- (ALR)-- 84 A @ 120 Vac: 42 A @ 240 Vac; Limit- (AFL)-- 8 A @ 120 Vac: 4 A @ 240 Vac; Limit- (ALR) 48 A @ 120 Vac: 24 A @ 240 Vac
- Approvals, Underwriters Laboratories Inc.
- Listed File MP466, Guide MBPR
- Approvals, CSA
- Certified: File No. LR1622
- Tradeline Value
- Tradeline
- Temperature Ratings (C)
- Maximum Ambient-- At switch 88 C: At element: 177 C; High Limit-- 38 C to 121 C; Fan-on-- 18 C to 102 C; Fan-off-- 10 C to 93 C
- Temperature Ratings (F)
- Maximum Ambient-- At switch: 190 F: At element: 350 F; High Limit-- 100 F to 250 F; Fan-on-- 65 F to 215 F; Fan-off-- 50 F to 200 F; High Limit Stop-- 200 F; Fan-on Stop-- 125 F; Fan-off Stop-- 100 F
- Operating Temperature Range (F)
- -40 F to +190 F
- Operating Temperature Range (C)
- -40 C to +88 C
- Differential Temperature (F)
- High limit 25 F
- Differential Temperature (C)
- High limit 14 C
- Switching Action
- Fan switch makes and high limit switch breaks on temperature rise.
- Element Insertion Length (in.)
- 11 1/2 in.
- Element Insertion Length (mm)
- 292 mm
- Pilot Duty Ratings
- 0.25 A @ 0.25 to 12 Vdc; 2 A @ 24 Vac