Description
EATON Soft Starter, Non-Combination Vertical Mount, Series: S611, 480 VAC, 65 A, 47/63 Hz Frequency, 50 hp Motor, 108/132 VAC Coil, 3 Pole, 0.5 to 180 s Timing, 3 ph, Lug Connection, Solid-State Overload Relay, 32.5 to 65 A Full Load, -20 to 50 deg C Operating, 7.64 in L x 11.58 in W x 19.45 in H Dimensions
Features:
- User interface module (UI) provides an intuitive, easy to use human interface with powerful configuration capabilities to maximize system performance
- Door or device mounted UI enables users to safely configure, commission, monitor and troubleshoot the system at the electrical panel without opening the enclosure door
- System operating parameters can be monitored enterprise wide through a communications network
- Increase uptime by providing data for process management and preventive diagnostics
- Run bypass mode greatly reduces internal heating created by the greater power dissipation in the SCRs, bypass contactors directly connect the motor to the line and improves system efficiency by reducing internal power losses
- Bypass contactors directly connect the motor to the line and improves system efficiency by reducing internal power losses
- Internal solid state overload protection provides accurate current measurement and trip settings
- Internal run bypass contactors and overload protection eliminate the need for additional devices, reducing enclosure sizes minimizing installation and wiring time and reducing overall assembly size and cost
- Wide range of overload FLA settings and a selectable trip class offers users the flexibility to fine tune the starter to match specific application requirements
- Variable ramp times and torque control settings provide unlimited starting configurations, allowing for maximum application flexibility
- Kick start feature enables soft starting of high friction loads
- Soft stop control for applications where an abrupt stop of the load is not acceptable
- 6 SCRs control all 3 motor phases, providing smooth acceleration and deceleration performance
- Soft acceleration and deceleration reduces wear on belts, gears, chains, clutches, shafts and bearings
- Reduce the peak inrush current stress on the power system
- Minimize peak starting torque to diminish mechanical system wear and damage
Applications:
Electrical Assemblies, Panels and EOEMs Applications
Standards/Approval:
- ANSI Specified
- CSA Certified File No. 3211-06
- IEC 60947-4-2
- UL 1449