KSCdirect

Product Data

KSCdirect Part #: CH S611C156P3S
Description: RVSS,3-PHASE,120V CONTROL,156 FLA,PUMP 3-3052-003B
MFG Part #: S611C156P3S
UPC: 786685480459
Supplier: CUTLER-HAMMER INC
Please use Live Chat or call 800-918-8939 for exact lead time.

Your Price: $13084.69 / EA

QTY:  
For shipping rates, add item to cart.
* Quantity discounts may be available. Call Kelly Supply at 800-918-8939.
Alternatively, you may e-mail info@kscdirect.com for service.

Details

Description

EATON Soft Starter, Non-Combination Reduced Voltage Standard, Series: S611, 130 to 600 VAC, 156 A, 47 to 63 Hz Frequency, 150 hp Motor, 120 VAC Coil, 3 Pole, Setting: 50 to 100%, 0.5 to 180 s Timing, 3 ph, Lug Connection, STOP/START Action, Solid-State Overload Relay, 78 to 156 A Full Load, Starting Modes: Soft Start/Current Limit/Kick Start/Ramp Start/Soft Stop, -20 to 50 deg C Operating, 21.01 in L x 11.58 in W x 8.57 in H Dimensions

Features:

  • The user interface module (UI) provides an intuitive, easy to use human interface with powerful configuration capabilities to maximize system performance
  • Door or device mounted UI enables users to safely configure, commission, monitor and troubleshoot the system at the electrical panel without opening the enclosure door, eliminating the possibility of an arc flash incident
  • System operating parameters can be monitored enterprise wide through a communications network, increase uptime by providing data for process management and preventive diagnostics
  • Run bypass mode greatly reduces internal heating created by the greater power dissipation in the SCRs, bypass contactors directly connect the motor to the line and improves system efficiency by reducing internal power losses
  • Internal solid state overload protection provides accurate current measurement and trip settings, sophisticated algorithms solve a series of differential equations that model true motor heating and cooling, resulting in superior motor overload protection while minimizing nuisance trips
  • Advanced selectable protective features safeguard the motor and system against a variety of system faults
  • Internal run bypass contactors and overload protection eliminate the need for additional devices, reducing enclosure sizes minimizing installation and wiring time and reducing overall assembly size and cost
  • Wide range of overload FLA settings (50 to 100% of rated frame current) and a selectable trip class (5 to 30) offers users the flexibility to fine tune the starter to match specific application requirements
  • Variable ramp times and torque control settings provide unlimited starting configurations, allowing for maximum application flexibility
  • Kick start feature enables soft starting of high friction loads
  • Soft stop control for applications where an abrupt stop of the load is not acceptable
  • Pump control option with sophisticated pump algorithms on both starting and stopping that minimize the pressure surges that cause water hammer, the pump control option will maximize the life of the pump and piping systems while minimizing the downtime caused by system failure
  • Six SCRs control all three motor phases, providing smooth acceleration and deceleration performance
  • Soft acceleration and deceleration reduces wear on belts, gears, chains, clutches, shafts and bearings
  • Reduce the peak inrush current stress on the power system
  • Minimize peak starting torque to diminish mechanical system wear and damage
  • 120 VAC control voltage enhances ease of connections
  • The S611 lends itself to serviceability, the printed circuit boards (PCBs) and contactors can be replaced in the field
  • The S611 has built-in communication capabilities through two communications ports to connect the soft starter to a variety of networks, including Modbus® (resident), DeviceNet, PROFIBUS and Ethernet
  • 50 hp at 208 V, 60 hp at 240 V, 125 hp at 480 V, 150 hp at 600 V

Applications:

Electrical Assemblies, Panels and EOEMs Applications

Standards/Approval:

  • CSA C22.2 No. 235
  • CSA No. 3211-06
  • IEC 60947-4-2
  • UL 1077

Warranty:

1 year

Attributes/Specifications

Action STOP/START
Amperage Rating 156 A
Coil Voltage 120 VAC
Connection Type Lug
Dimensions 21.01 in L x 11.58 in W x 8.57 in H
Frequency Rating 47 to 63 Hz
Full Load Current 78 to 156 A
Motor Power 150 hp
Number of Poles 3
Operating Temperature -20 to 50 deg C
Overload Relay Solid-State
Phase 3
Series S611
Setting 50 to 100%
Starting Modes Soft Start/Current Limit/Kick Start/Ramp Start/Soft Stop
Timing 0.5 to 180 s
Type Non-Combination Reduced Voltage Standard
Manufacturer CUTLER-HAMMER INC

Supplemental Files