KSCdirect

Product Data

KSCdirect Part #: CH 8075A34G01
Description: 50VCP-W350-1200 48VDC M&CL 48VDC TRIP 8075A34G01
MFG Part #: 8075A34G01
UPC: 786685512167
Supplier: CUTLER-HAMMER INC
Variable lead time item; we expect to ship this promptly.
You will be notified of any delay and may cancel at that time.

Your Price: $89009.50 / EA

QTY:  
For shipping rates, add item to cart.
* Quantity discounts may be available. Call Kelly Supply at 800-918-8939.
Alternatively, you may e-mail info@kscdirect.com for service.

Details

Description

EATON Vacuum Circuit Breaker, Type VCP-W Medium Voltage, 48 VDC, 1200 A, 60 Hz Frequency, 350 kA Interrupt, -15 to 40 deg C, 37 in L x 37 in W x 41 in H Dimensions

Features:

  • Premium control wires and terminals provide reliable control and protection for electrical equipment and circuits and are capable of being operated manually under full load conditions
  • Represents a common line that utilizes common parts, standardization provides for fewer total parts which, in turn, reduces and simplifies spare parts inventory
  • Front accessible mechanism allows for easy access to The mechanism and user friendly control components
  • Provides higher insulation levels in less space, thus reducing the overall switchgear size
  • EATON patented V-flex system features fewer moving parts which allows for vacuum stem movement without friction and without The wear normally associated with rolling/sliding designs
  • Unlike sliding or rolling designs, there are no moving parts to wear out, requiring no maintenance and resulting in longer circuit breaker life
  • Spiral contact design provides a self induced magnetic effect that moves The arc root around The contact periphery, this efficient arc control prevents hot spots and minimizes contact erosion
  • Double dead front shields isolate the operator from high voltage when the breaker is energized, providing optimum operator safety
  • Mechanically and electrically trip-free stored energy mechanism design ensures that while holding a mechanical trip command, breaker contacts will not close or touch even if an electrical or mechanical close command is received
  • Closing springs will discharge automatically when the breaker is withdrawn from or inserted into its compartment, for added user safety

Applications:

Electrical Assemblies, Panels, EOEMs, Small and Mid-Sized Hydro Power Generator, Electrical Generator, Power Plant, Combined Cycle/Combustion Turbines, Paper, Chemical and Manufacture Companies with Backup Power Plant Applications

Standards/Approval:

  • BAA Compliant
  • IEC 56

Attributes/Specifications

Amperage Rating 1200 A
Dimensions 37 in L x 37 in W x 41 in H
Frequency Rating 60 Hz
Interrupt Rating 350 kA
Temperature Rating -15 to 40 deg C
Type Type VCP-W Medium Voltage
Voltage Rating 48 VDC
Manufacturer CUTLER-HAMMER INC