KSCdirect

Product Data

KSCdirect Part #: CH 3776A18G06
Description: 150VCP-W500-1200 SE 125VDC M&CL 125VDC
MFG Part #: 3776A18G06
UPC: 786685510026
Supplier: CUTLER-HAMMER INC
Variable lead time item; we expect to ship this promptly.
You will be notified of any delay and may cancel at that time.

Your Price: $106429.20 / EA

QTY:  
For shipping rates, add item to cart.
* Quantity discounts may be available. Call Kelly Supply at 800-918-8939.
Alternatively, you may e-mail info@kscdirect.com for service.

Details

Description

EATON Vacuum Circuit Breaker, Type VCP-W Medium Voltage, 8.25 kV, 2000 A, 500 MVA, 60 Hz, 33 kA Interrupt, 3 Poles, -15 to 40 deg C, 29.44 in H x 29.56 in W x 29.81 in D

Features:

  • Premium control wires and terminals provide reliable control and protection for electrical equipment and circuits and are capable of being operated manually under full load conditions
  • Represents a common line that utilizes common parts, standardarization provides for fewer total parts which, in turn, reduces and simplifies spare parts inventory
  • Front accessible mechanism allows for easy access to The mechanism and user friendly control components
  • Provides higher insulation levels in less space, thus reducing The overall switchgear size
  • EATON patented V-FLEX system features fewer moving parts which allows for vacuum stem movement without friction and without The wear normally associated with rolling/sliding designs
  • Unlike sliding or rolling designs, there are no moving parts to wear out, requiring no maintenance and resulting in longer circuit breaker life
  • Spiral contact design provides a self induced magnetic effect that moves The arc root around The contact periphery, this efficient arc control prevents hot spots and minimizes contact erosion
  • Double dead front shields isolate The operator from high voltage when The breaker is energized, providing optimum operator safety
  • Mechanically and electrically trip free stored energy mechanism design ensures that while holding a mechanical trip command, breaker contacts will not close or touch even if an electrical or mechanical close command is received
  • Closing springs will discharge automatically when The breaker is withdrawn from or inserted into it's compartment, for added user safety

Applications:

Small and Mid-Sized Hydro Power Generator, Electrical Generator, Power Plant, Combined Cycle/Combustion Turbines, Paper, Chemical and Manufacture Companies with Backup Power Plant

Standards/Approval:

  • IEC 56

Attributes/Specifications

Amperage Rating 2000 A
Dimensions 29.44 in H x 29.56 in W x 29.81 in D
Frequency Rating 60 Hz
Interrupt Rating 33 kA
Number of Poles 3
Power Rating 500 MVA
Temperature Rating -15 to 40 deg C
Type Type VCP-W Medium Voltage
Voltage Rating 8.25 kV
Manufacturer CUTLER-HAMMER INC