HOME

Product Data

KSCdirect Part #: OSR 21577
Description: FO32/841/XP/XL/ECO
MFG Part #: 21577
UPC: 4613521577

Your Price: $22.27 / EA

QTY:
* Quantity discounts may be available. Call 800-918-8939.
Alternatively, you may E-mail info@kscdirect.com for service.

FO32/841/XP/XL/ECO



Product
Number:
21577
Order
Abbreviation:
FO32/841/XP/XL/ECO
General
Description:
48" MOL; T8 OCTRON XP Extended Performance; Longer Life; 4100K color temperature; rare earth phosphor; 85 CRI; ECOLOGIC; suitable for operation on IS or RS ballast
Quantity: EA
Product Information
Abbrev. With Packaging Info. FO32841XPXLECO 30/CS 1/SKU
Actual Length (in) 47.78
Actual Length (mm) 1213.6
Average Rated Life (hr) 36000
Base Medium Bipin
Bulb T8
Color Rendering Index (CRI) 85
Color Temperature/CCT (K) 4100
Diameter (in) 1.10
Diameter (mm) 27.9
Family Brand Name OCTRON XP XL ECO
Industry Standards ANSI C78.81 - 2005
Initial Lumens at 25C 2950
Mean Lumens at 25C 2861
Nominal Length (in) 48
Nominal Wattage (W) 32.00
Additional Product Information
Product Documents, Graphs, and Images
Packaging Information
Footnotes
  • This lamp may also be operated by the OSRAM SYLVANIA QUICKTRONIC(R) PSN ballast (.88 BF), or the QUICTRONIC PSX ballast (.71 BF).
  • The lamp lumen maintenance factor used to determine the mean lumen value was 97%. This is the lamp lumen maintenance factor at 8000 hours, 40% of 20,000 hours. It was used for comparison to standard OCTRON lamps with an average rated life of 20,000 hours. The lamp lumen maintenance factor at 40% of 40,000 hours, 16000 hours, would be 93%.
  • The life of this lamp, operated on instant start electronic ballasts is 36,000 hours based on the industry standard life test standard of 3 hours per start.
  • The 40,000 hour average rated life of the FO32/800XP/XL/ECO and FO32/25W/800XP/XL/SS/ECO OCTRON lamps is based on operation at 3 hours per start on a QUICKTRONIC programmed start ballast. If operated on other ballasts for T8 OCTRON lamps, lamp life will be 40,000 hours for programmed rapid start operation and 36,000 hours for instant start operation at 3 hours per start.
  • Approximate initial lumens after 100 hours operation.
  • The life ratings of fluorescent lamps are based on 3 hr. burning cycles under specified conditions and with ballast meeting ANSI specifications. If burning cycle is increased, there will be a corresponding increase in the average hours life.
  • SYLVANIA ECOLOGIC fluorescent lamps are designed to pass the Federal Toxic Characteristic Leaching Procedure (TCLP) criteria for classification as non-hazardous waste in most states. TCLP test results are available upon request. Lamp disposal regulations may vary, check your local & state regulations. For more information, please visit www.lamprecycle.org


Keywords: Osram Sylvania





Powered by Venture