120V SPST 40A 7 DAY MECHANICAL TIME SWITCH
NSI / Tork Electrical, Lighting Pool & Spa Products and Replacement Parts
CAT UPC HP MOTOR: FREQUENCY
NO CODE SWITCH AMPS RATING AC VOLTAGE Hz
W100 30001 SPST 40 2 120 60
W200 31001 DPST 40 2 120 60
W202 31011 DPST 40 5 208-277 60
W300 32001 3PST 40 2 120 60
W302 32002 3PST 40 5 208-277 60
W120 33001 SPDT 40 2 120 60
W220 34001 DPDT 40 2 120 60
W222 34011 DPDT 40 5 208-277 60
W400A 35001 4PST 40 2 120 60
W402A 35002 4PST 40 5 208-277 60
WITH RESERVE POWER
W300L 39005 3PST 40 2 120 60
W302L 39006 3PST 40 5 208-277 60
W220L 39009 DPDT 40 2 120 60
W222L 39010 DPDT 40 5 208-277 60
W400AL 39007 4PST 40 2 120 60
24 VOLT IN ALL MODELS AVAILABLE ON SPECIFICATION.
WIRING DIAGRAMS
W100 (SPST) W200 (DPST) W300 (3PST) W120 (SPDT) W220 (DPDT)
M M
M M M
L 1 X 2
L 1 X 2 H
L 1 X 2
L
3 4 L 1 X 2 H LOAD
L 2
H N
LOAD LOAD
L H
H H 5 6 LOAD LOAD L 3
LOAD 5 4 LOAD
N A B
N L
H LOAD LOAD LOAD N LOAD LOAD
H
N
N N
N
W400A (4PST)
Equipment
Ground M
A 1 2 3 4
Clock Motor
Supply
5 6 7 8
B
Supply
To Load(s)
SPECIFICATION WRITERS GUIDE W SERIES
Furnish and install where shown TORK Time Switch of the 7 day type, powered by a self-starting synchronous motor, capable of being set for different ON-OFF times each
day of the week, to an operating accuracy of plus or minus 15 minutes of the desired time. Time Switch contacts shall be capable of switching 40 amperes per pole contin-
uously at 277 volts and shall be SPST (DPST, 3PST, DPDT, SPDT, 4PST as required). Removable ON-OFF trippers shall make possible automatic operation with a minimum
ON period of one hour and a minimum of 2 hours between one OFF operation and the next ON. Models W400 and W402 offer minimum ON and OFF settings of 3-1/2
hours. Enclosure shall be NEMA 1 surface, nished in baked beige enamel, with combination 1/2 - 3/4 knock-outs on bottom and both sides. Provision shall be made for
positive padlocking. Terminals shall be capable of receiving #8 AWG wire. Time Switch shall be TORK Model W_ _ _ (to t requirement).
FOR RESERVE POWER (Add sufx L): Spring-driven reserve shall be provided sufcient to operate the Time Switch contacts at least 24 hours after power failure (16 hour
reserve power on 4PST models). On restoration of power, Time Switch shall transfer to synchronous motor driven and automatically rewind reserve power unit.
15
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
CAT UPC HP MOTOR: FREQUENCY
NO CODE SWITCH AMPS RATING AC VOLTAGE Hz
W100 30001 SPST 40 2 120 60
W200 31001 DPST 40 2 120 60
W202 31011 DPST 40 5 208-277 60
W300 32001 3PST 40 2 120 60
W302 32002 3PST 40 5 208-277 60
W120 33001 SPDT 40 2 120 60
W220 34001 DPDT 40 2 120 60
W222 34011 DPDT 40 5 208-277 60
W400A 35001 4PST 40 2 120 60
W402A 35002 4PST 40 5 208-277 60
WITH RESERVE POWER
W300L 39005 3PST 40 2 120 60
W302L 39006 3PST 40 5 208-277 60
W220L 39009 DPDT 40 2 120 60
W222L 39010 DPDT 40 5 208-277 60
W400AL 39007 4PST 40 2 120 60
24 VOLT IN ALL MODELS AVAILABLE ON SPECIFICATION.
WIRING DIAGRAMS
W100 (SPST) W200 (DPST) W300 (3PST) W120 (SPDT) W220 (DPDT)
M M
M M M
L 1 X 2
L 1 X 2 H
L 1 X 2
L
3 4 L 1 X 2 H LOAD
L 2
H N
LOAD LOAD
L H
H H 5 6 LOAD LOAD L 3
LOAD 5 4 LOAD
N A B
N L
H LOAD LOAD LOAD N LOAD LOAD
H
N
N N
N
W400A (4PST)
Equipment
Ground M
A 1 2 3 4
Clock Motor
Supply
5 6 7 8
B
Supply
To Load(s)
SPECIFICATION WRITERS GUIDE W SERIES
Furnish and install where shown TORK Time Switch of the 7 day type, powered by a self-starting synchronous motor, capable of being set for different ON-OFF times each
day of the week, to an operating accuracy of plus or minus 15 minutes of the desired time. Time Switch contacts shall be capable of switching 40 amperes per pole contin-
uously at 277 volts and shall be SPST (DPST, 3PST, DPDT, SPDT, 4PST as required). Removable ON-OFF trippers shall make possible automatic operation with a minimum
ON period of one hour and a minimum of 2 hours between one OFF operation and the next ON. Models W400 and W402 offer minimum ON and OFF settings of 3-1/2
hours. Enclosure shall be NEMA 1 surface, nished in baked beige enamel, with combination 1/2 - 3/4 knock-outs on bottom and both sides. Provision shall be made for
positive padlocking. Terminals shall be capable of receiving #8 AWG wire. Time Switch shall be TORK Model W_ _ _ (to t requirement).
FOR RESERVE POWER (Add sufx L): Spring-driven reserve shall be provided sufcient to operate the Time Switch contacts at least 24 hours after power failure (16 hour
reserve power on 4PST models). On restoration of power, Time Switch shall transfer to synchronous motor driven and automatically rewind reserve power unit.
15
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
ACCESSORIES
CAT UPC
NO CODE DESCRIPTION
PK100 95110 Parts Kit includes parts cabinet and 24 P47, 5 P49, 28 P69, 10 P14, 4 101M motors, 2 201M motors.
P-47 95001 Pair Standard Screw-On Type Trippers for 1100 Series (except FM models)
and all 7000 and 1800 Series models. Does not advance day omitting wheel.
K24 95026 Kit of 24 pairs of P-47 Trippers.
PF48 95003 Pair of standard trippers for 1100 FM Series.
P-49 95002 Special ON tripper for 7000 Series to also advance day omitting wheel. Standard OFF tripper included.
P-69 85003 Screw-On Type Trippers reversible ON and OFF for use on all models with 612 dia.
7 day dial (except W400 Series). Available only in packages of 7 pairs.
P-69I 85004 ON and OFF Trippers for W400 Series. Available only in packages of 7 pairs.
P-41 95400 ON & OFF trippers for plug-in timers Models 401, 421, 431.
P-14 95006 Omitting screws for inserting into tapped hole of appropriate spoke of day omitting wheel. Color: Black.
P-26 95007 Selector screws for 4000 (Double Dial) Series Provides Extra Operations Daily. Color: Copper
KN500 95027 For 2 conduit. Grounding bushings for use with Noryl enclosures and metal conduit. Fits #10-14 AWG ground wires. 2 bushings per kit.
1
KN750 95028 For 34 conduit. Grounding bushings for use with Noryl enclosures and metal conduit. Fits #10-14 AWG ground wires. 2 bushings per kit.
64140 95008 480/120v Step-down Transformer only for 480v power input. 7.8 VA (for use with Model 7100, 8001, 8007 only).
71018 95009 24/120V Step-up Transformer. 50VA.
Mounting Brackets for mounting unit less case. Specify CAT UPC
model number, date of manufacture, and whether NO CODE DESCRIPTION
model mounts by snapping into case, or with screws.
MODEL NO: 65447 70159 95050 W. Dial for T900, TW, 1847AW,
and W controls except W400A
UPC CODE: 95020
All 24 hour models except 3-pole, 73713-4 95051 24 hour dial for 7100 Series
including reserve power models 73713-5 95052 24 hour dial for 1100 Series, 1847A Series
53032-17 95053 FM Series dial for 1100FM; 1100FMM
MODEL NO: 64040 (CK-7300) 64041 95054 8001 Dial
UPC CODE: 95023
64041-1 95055 8007 Dial
24 Hour 3-pole for Models 7300, 7302.
64041-2 95056 8601 Dial
64041-6 95059 8301 Dial
MODEL NO: 64039
64041-5 95058 8121 Dial
UPC CODE: 95021
for W SERIES 7 Day Models: 64041-4 95057 8061 Dial
W100, W200, W202, W120, W220, W222. 73855 95060 Wallplate for 701A
73856-1 95061 Wallplate for 701A-2G
MODEL NO: 62153-1 90031-17 95062 Relay for T-900 Series
UPC CODE: 95022 74240-2 95063 White Knob for A500 Series
W SERIES 7 Day 3-pole for Models W300, 74240-I 95064 Ivory Knob for A500 Series
W302.
74240-3 95065 Black Knob for C500 Series
59201-1 95024 Micro-switch for 8001 and M8000 units
59201-26 95025 Micro-switch for 8007 units
73192-3 95030 Adapter plate allows DG series to snap into
7 day (W Series) Time Switch Enclosure
25
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
ENCLOSURE & MECHANISM DIMENSIONS
METAL INDOOR NEMA 1 METAL INDOOR/OUTDOOR 5-1/4"
#68229 NEMA 3
STD. FOR
MODELS
4-11/16" Model 9000A Suffix O 8-1/4"
1101 7200 8121
1102 7202 8301 STD. FOR MODELS
1103 7120 8601 7-15/16"
7300, (L) 7302Z
1104 7122 8602 7302, (L) 7300ZL 4-5/8"
1101FM 8001 TORK 7300Z 7302ZL
1104FM 8004
AVAILABLE FOR MODELS
7100 8061
2-15/16" 1101 7200, (L,Z,ZL) 1847AL 8007V
7102 1102 7202, (L,Z,ZL) 1847AZL 8061
1103 7120, (L,Z,ZL) 8001 8121
1104 7122, (L,ZL) 8004 8301
1101FM 7220, (L) 8001U 8601
1104FM 7222, (L) 8007 8602
METAL INDOOR NEMA 1 7100 1847A 8007L
#63100 7102 1847AZ
5"
STD. FOR MODELS
7220, (L) 1847AL
7222, (L) 1847AZL
7200L 8007 9-1/4"
7202L 8007L
METAL INDOOR/OUTDOOR
7120L 8007V
NEMA 3 8-3/8 "
1847A 8150
TORK
Model 9006 Suffix O
1848A 8150U AVAILABLE FOR MODELS
1849A W100 W220 TW220L 13-1/8"
3-3/4" W200 W222 TW300L
1847AZ
W202 W220L T920L
W300 W222L T930L
W302 W300L 1847AW
W120 W302L 1847AWL 5-3/16 "
METAL INDOOR NEMA 1
#63016-1 8-1/8"
STD. FOR MODELS
TZ220L W302L
5"
12-1/8 "
TZ300L TW220L NORYL INDOOR/OUTDOOR
W300 TW300L
TORK NEMA 3R
W302 T920L
W300L T930L
Model 9000N Suffix N 9-1/8"
STD. FOR MODELS
4-3/4"
7200Z,(L, ZL) TORK
7202Z,(L, ZL)
7120Z,(L, ZL)
4-1/2"
7122Z, (L, ZL)
METAL INDOOR NEMA 1 AVAILABLE FOR MODELS
#70100 7-5/8 " 1101 7102 7222, (L) 8001U
1102 7200, (L) 1847A 8061
STD. FOR MODELS 1103 7202, (L) 1847AZ 8121
W100 W222 1104 7120, (L) 1847AL 8301
1101FM 7122, (L) 1847AZL 8601
W200 W220L
11-7/8 "
1104FM 7220, (L) 8001 8602
W202 W222L 7100 8004
W120 1847AW TORK
W220 1847AWL
3-1/4 "
METAL INDOOR NEMA 1 NORYL & LEXAN 5"
for W400 Series NEMA 3R
12 -1/2" INDOOR/OUTDOOR TORK 9-1/8"
STD. FOR MODELS Model 9000NC
W400A W400AL
STD. FOR MODELS
W402A W402AL 1101NC
4" 1103NC
4-1/2"
8 -1/4" 1104NC
26
A DIVISION OF NSi INDUSTRIES, LLC
ENCLOSURE & MECHANISM DIMENSIONS
METAL INDOOR NEMA 1 METAL INDOOR/OUTDOOR 5-1/4"
#68229 NEMA 3
STD. FOR
MODELS
4-11/16" Model 9000A Suffix O 8-1/4"
1101 7200 8121
1102 7202 8301 STD. FOR MODELS
1103 7120 8601 7-15/16"
7300, (L) 7302Z
1104 7122 8602 7302, (L) 7300ZL 4-5/8"
1101FM 8001 TORK 7300Z 7302ZL
1104FM 8004
AVAILABLE FOR MODELS
7100 8061
2-15/16" 1101 7200, (L,Z,ZL) 1847AL 8007V
7102 1102 7202, (L,Z,ZL) 1847AZL 8061
1103 7120, (L,Z,ZL) 8001 8121
1104 7122, (L,ZL) 8004 8301
1101FM 7220, (L) 8001U 8601
1104FM 7222, (L) 8007 8602
METAL INDOOR NEMA 1 7100 1847A 8007L
#63100 7102 1847AZ
5"
STD. FOR MODELS
7220, (L) 1847AL
7222, (L) 1847AZL
7200L 8007 9-1/4"
7202L 8007L
METAL INDOOR/OUTDOOR
7120L 8007V
NEMA 3 8-3/8 "
1847A 8150
TORK
Model 9006 Suffix O
1848A 8150U AVAILABLE FOR MODELS
1849A W100 W220 TW220L 13-1/8"
3-3/4" W200 W222 TW300L
1847AZ
W202 W220L T920L
W300 W222L T930L
W302 W300L 1847AW
W120 W302L 1847AWL 5-3/16 "
METAL INDOOR NEMA 1
#63016-1 8-1/8"
STD. FOR MODELS
TZ220L W302L
5"
12-1/8 "
TZ300L TW220L NORYL INDOOR/OUTDOOR
W300 TW300L
TORK NEMA 3R
W302 T920L
W300L T930L
Model 9000N Suffix N 9-1/8"
STD. FOR MODELS
4-3/4"
7200Z,(L, ZL) TORK
7202Z,(L, ZL)
7120Z,(L, ZL)
4-1/2"
7122Z, (L, ZL)
METAL INDOOR NEMA 1 AVAILABLE FOR MODELS
#70100 7-5/8 " 1101 7102 7222, (L) 8001U
1102 7200, (L) 1847A 8061
STD. FOR MODELS 1103 7202, (L) 1847AZ 8121
W100 W222 1104 7120, (L) 1847AL 8301
1101FM 7122, (L) 1847AZL 8601
W200 W220L
11-7/8 "
1104FM 7220, (L) 8001 8602
W202 W222L 7100 8004
W120 1847AW TORK
W220 1847AWL
3-1/4 "
METAL INDOOR NEMA 1 NORYL & LEXAN 5"
for W400 Series NEMA 3R
12 -1/2" INDOOR/OUTDOOR TORK 9-1/8"
STD. FOR MODELS Model 9000NC
W400A W400AL
STD. FOR MODELS
W402A W402AL 1101NC
4" 1103NC
4-1/2"
8 -1/4" 1104NC
26
A DIVISION OF NSi INDUSTRIES, LLC
METAL DUPLEX METAL FLUSH NEMA 1
NEMA 3 10-3/8" Model 9001 Suffix FL1
INDOOR/OUTDOOR Model 9002 Suffix FL2*
Model 9004L 8"
11-9/32 "
Suffix DUOL AVAILABLE FOR MODELS
1101 7200, (L,Z,ZL)
STD. FOR MODELS
1102 7202, (L,Z,ZL)
1101D 1101DF 7120, (L,Z,ZL)
1103 11" 9-1/8"
1114D 1114DF 1104 7122, (ZL)
4-1/4"
1104D 1104DF 1101FM 7220, (L)
AVAIL. FOR MODELS 1104FM 7222, (L)
6-1/8"
1101 7100 7100 8000 Series
4-3/16"
1102 7102 7102
1103 7200, (L,Z,ZL)
1104 7202, (L,Z,ZL) *Model 9002 (FL2) Depth is 4-9/16
1101FM 7120, (L,Z,ZL) For Models 7300 and 7302
1104FM 7122, (ZL)
7220, (L)
7222, (L)
MODELS
4-9/16"
8601
8602
MODELS:
1101 1847A 4-9/16" 3-1/2" 8301 5-3/4"
1102 1848A 8121
1103 8061
1849A 3-1/2"
1104
1847AZ MECHANISM WITH MOUNTING
1101FM 7-1/2"
1848AZ ONLY BRACKET
1104FM #65447
1849AZ
7100
7102 1847AL 7-5/8"
3-1/2"
7200, (L,Z,ZL) 1848AL MODELS
2-1/2"
7202, (L,Z,ZL) 1849AL MECHANISM WITH MOUNTING W100
ONLY BRACKET W200
11-1/2"
7120, (L,Z,ZL) 1847AZL #65447
W202
7122, (ZL) 1848AZL W120
7220, (L)
1849AZL W220 MECHANISM WITH MOUNTING
7222, (L) ONLY BRACKET
W222
#64039
4-1/4"
4-9/16"
MODELS: 7-5/8"
7300, (L,Z,ZL) 3-5/8 "
7302, (L,Z,ZL)
7-1/2" MODELS 3-1/16"
W300
11-1/2"
W302
MECHANISM WITH MOUNTING
ONLY BRACKET MECHANISM WITH MOUNTING
#64040 ONLY BRACKET
#62153-1
MODELS 4-9/16"
7-3/4" 3-1/2"
8001 MODELS
8004 1847AWL
5-5/8" 11-1/2"
8007 1848AWL
8008 1849AWL
3-1/2"
MECHANISM WITH MOUNTING MECHANISM WITH MOUNTING
ONLY BRACKET ONLY BRACKET
#65447 #65447
27
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
ALPHANUMERIC INDEX TERMS OF SALE
CATALOG TORK VENDOR NUMBER: 786261
NUMBER PAGE
1. Prices are F.O.B. our plant.
36/46 . . . . . . . . . . . . . . . . . . . . . . 21 2. Prices do not include any sales tax.
401A, 402A, 407A . . . . . . . . . . . . . 24 3. Freight charges will be prepaid on all orders $250.00 and over
437R, 451A . . . . . . . . . . . . . . . . . . 24 shipping within continental USA using standard shipping meth-
601A, 602A, 611A . . . . . . . . . . . . . 24 ods and service.
651A, 652A . . . . . . . . . . . . . . . . . . 24 4. Minimum order $100.00.
701A, 711A . . . . . . . . . . . . . . . . . . 22 5. Claims for shortage, erroneous charges or price corrections shall
806A . . . . . . . . . . . . . . . . . . . . . . . 24 be deemed waived unless made in writing, delivered to NSi
1101 etc . . . . . . . . . . . . . . . . . . . . 2,3 within 30 days of invoice.
1101 etc (Pool) . . . . . . . . . . . . . . . . . 6 6. Terms of payment 2% 10th prox. net 25th following.
1847, 1848 . . . . . . . . . . . . . . . . . . 10 7. Warranties NSi guarantees all products to be free of defects in
7100 etc . . . . . . . . . . . . . . . . . . . . 4,5 material and workmanship for a period of 1 year from date of
7200Z etc . . . . . . . . . . . . . . . . . 14,15 sale. Any claims for defective material must be agreed to in
8001 etc . . . . . . . . . . . . . . . . . . . . 11 writing by NSi. Defective material will be replaced on an F.O.B.
8601 etc . . . . . . . . . . . . . . . . . . . . 12 our factory basis. NSi disclaims the implied warranty of tness
for a particular application.
A505 etc . . . . . . . . . . . . . . . . . . . . 23
C505 etc . . . . . . . . . . . . . . . . . . . . 23
IAP . . . . . . . . . . . . . . . . . . . . . . . . . 21
M500 . . . . . . . . . . . . . . . . . . . . . . . 22 OTHER PRODUCTS AVAILABLE
T920, T930 . . . . . . . . . . . . . . . . . . 18
NSi can provide many other products for special applications which
TW220L, TW222L . . . . . . . . . . . 16,17
are not listed in this catalog. If you require an item which you do
TW300L, TW302L . . . . . . . . . . . 16,17
not nd listed, please contact us. We would be pleased to provide a
TZ220L, TZ222L . . . . . . . . . . . . . . . 20
quotation upon receipt of a drawing or a sample.
TZ300L, TZ302L . . . . . . . . . . . . . . . 20
W100, W200 etc . . . . . . . . . . . . 14,15
WH . . . . . . . . . . . . . . . . . . . . . . . . . 7
ZKIT . . . . . . . . . . . . . . . . . . . . . . . . 21
GUARANTEE
It is our goal to provide extraordinary products and service on a
daily basis. If our products or service do not meet with your satis-
faction, please let us know immediately and we promise to make
every reasonable effort to remedy the situation.
29
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
Cable Connectors and Fittings
EMT CONNECTORS, CONDUIT BODIES AND NIPPLES, REDUCING WASHERS, BUSHINGS
ThINWALL E.M.T. CoNNECToRS
1 2 3 4 5 Connectors are zinc
plated die cast.
CATALOG UPC TRADE QTY QTY/
NO. NO. DESCRIPTION FIG. SIZE (IN.) KO (IN.) PK CTN
ZiNC DiE CASt
EMt50C-D 78609 Compression type Connectors 1 8 12
EMt75C-D 78610 Compression type Connectors 1 8 12
EMtL50C-D 78611 Compression for EMt to Liquid-tight 2 - 1 12
EMtL75C-D 78612 Compression for EMt to Liquid-tight 2 - 1 12
EMt5090C-D 78613 Compression type 90 Connectors 3 2 12
EMt7590C-D 78614 Compression type 90 Connectors 3 2 12
EMt50CC-D 78615 Compression type Couplings 4 - 8 12
EMt75CC-D 78616 Compression type Couplings 4 - 8 12
EMt50S-D 78617 Set Screw type Offset Connectors 5 4 12
EMt75S-D 78618 Set Screw type Offset Connectors 5 4 6
RIgId CoNduIT BodIES
CATALOG UPC TRADE BODY QTY/ QTY/
NO. NO. DESCRIPTION SIZE (IN.) TYPE PK CTN
RCLB50-D 78619 with steel cover, screws & gasket LB(back) 1 12
RCLB75-D 78620 with steel cover, screws & gasket LB(back) 1 12
CoNduIT NIPPLES
CATALOG UPC QTY/ CTN
NO. NO. DESCRIPTION SIZE PK QTY
CNZO50-D 78621 Offset Connection, zinc die cast steel 2 12
CNZO75-D 78622 Offset Connection, zinc die cast steel 2 12
CNGS50-D 78623 Straight connection, galvanized steel 2 12
REduCINg WAShERS
For reducing CATALOG UPC REDUCES SIZE (IN.) QTY/ QTY/
knockout holes. NO. NO. DESCRIPTION FROM TO PK CTN
Washers have RW10050-D 78624 reducing washers 1 10 24
raised flanges RW10075-D 78625 reducing washers 1 10 24
for a tight fit; RW7550-D 78627 reducing washers 28 12
made of galva- RW20075-D 78628 reducing washers 2 5 12
nized steel. RW15050-D 78629 reducing washers 1 4 12
RW15075-D 78630 reducing washers 1 4 12
kNoCkouT SEALS
ANd hoLE PLug CATALOG UPC QTY/ QTY/
NO. NO. DESCRIPTION PK CTN
KOP50-D 78631 for knockouts, zinc plated steel 10 12
KOP75-D 78632 for knockouts, zinc plated steel 10 12
BuShINgS
CATALOG UPC QTY/ QTY/
NO. NO. DESCRIPTION PK CTN
PBBX-1-D 78633 plastic bushings for 14/2, 14/3 & 12/2 BX 35 24
20 Nsi Phone: 800.321.5847 Fax: 800.841.5566
Cable Connectors and Fittings
EMT CONNECTORS, CONDUIT BODIES AND NIPPLES, REDUCING WASHERS, BUSHINGS
ThINWALL E.M.T. CoNNECToRS
1 2 3 4 5 Connectors are zinc
plated die cast.
CATALOG UPC TRADE QTY QTY/
NO. NO. DESCRIPTION FIG. SIZE (IN.) KO (IN.) PK CTN
ZiNC DiE CASt
EMt50C-D 78609 Compression type Connectors 1 8 12
EMt75C-D 78610 Compression type Connectors 1 8 12
EMtL50C-D 78611 Compression for EMt to Liquid-tight 2 - 1 12
EMtL75C-D 78612 Compression for EMt to Liquid-tight 2 - 1 12
EMt5090C-D 78613 Compression type 90 Connectors 3 2 12
EMt7590C-D 78614 Compression type 90 Connectors 3 2 12
EMt50CC-D 78615 Compression type Couplings 4 - 8 12
EMt75CC-D 78616 Compression type Couplings 4 - 8 12
EMt50S-D 78617 Set Screw type Offset Connectors 5 4 12
EMt75S-D 78618 Set Screw type Offset Connectors 5 4 6
RIgId CoNduIT BodIES
CATALOG UPC TRADE BODY QTY/ QTY/
NO. NO. DESCRIPTION SIZE (IN.) TYPE PK CTN
RCLB50-D 78619 with steel cover, screws & gasket LB(back) 1 12
RCLB75-D 78620 with steel cover, screws & gasket LB(back) 1 12
CoNduIT NIPPLES
CATALOG UPC QTY/ CTN
NO. NO. DESCRIPTION SIZE PK QTY
CNZO50-D 78621 Offset Connection, zinc die cast steel 2 12
CNZO75-D 78622 Offset Connection, zinc die cast steel 2 12
CNGS50-D 78623 Straight connection, galvanized steel 2 12
REduCINg WAShERS
For reducing CATALOG UPC REDUCES SIZE (IN.) QTY/ QTY/
knockout holes. NO. NO. DESCRIPTION FROM TO PK CTN
Washers have RW10050-D 78624 reducing washers 1 10 24
raised flanges RW10075-D 78625 reducing washers 1 10 24
for a tight fit; RW7550-D 78627 reducing washers 28 12
made of galva- RW20075-D 78628 reducing washers 2 5 12
nized steel. RW15050-D 78629 reducing washers 1 4 12
RW15075-D 78630 reducing washers 1 4 12
kNoCkouT SEALS
ANd hoLE PLug CATALOG UPC QTY/ QTY/
NO. NO. DESCRIPTION PK CTN
KOP50-D 78631 for knockouts, zinc plated steel 10 12
KOP75-D 78632 for knockouts, zinc plated steel 10 12
BuShINgS
CATALOG UPC QTY/ QTY/
NO. NO. DESCRIPTION PK CTN
PBBX-1-D 78633 plastic bushings for 14/2, 14/3 & 12/2 BX 35 24
20 Nsi Phone: 800.321.5847 Fax: 800.841.5566
POOL/SPA PANELS ENCLOSURE ONLY
TOTAL FLEXIBILITY:
YOUR CHOICE!
TORK pool/spa panel enclo- PP-20R
sures are available without
time switches, allowing you to
choose our new P1100 Series
and PEW100 Series, or the
customary 1100 Series time
switch mechanism, depending
on your requirements.
PP-100R PP-125R
SHOWN WITH
DOOR CLOSED
CATALOG UPC
NO CODE DESCRIPTION
PP-20R 94015 NEMA 3R 40A Pool/Spa Panel with Inside Wiring Compartment. Removable/reversible
side opening door. Provisions for installing (1) time switch mechanism/module and
(2) While-in-use wiring devices, 2-circuit 20A load center for supplemental 120V circuit/convenience outlet
PP-100R 94016 NEMA 3R 100 Amp Pool/Spa Panel with Inside Wiring Compartment. Removable/reversible
side opening door. 100A, 120/240V 5 space, 10 circuit load center with provisions for installing (2) time switch
mechanisms and Inside Wiring Compartment for (2) While-in-use wiring devices & (2) Device plates
PP-125R 94017 NEMA 3R 120 Amp Pool/Spa Panel with Inside Wiring Compartment. Removable/reversible
side opening door. 120A, 120/240V 8 space, 16 circuit load center with provisions for installing (2) time switch
mechanisms and Inside Wiring Compartment for (2) While-in-use wiring devices & (2) Device plates
One or more of the following patents apply: 6.753.485, 6.791.039, 6.827.230B1, 6.930.268. Additional Patents pending.
6
A DIVISION OF NSi INDUSTRIES, LLC
CATALOG UPC DRY SET MIN
TYPE NO CODE CONTACTS SCHEDULING POINTS SETTING
E101B 82401 SPST SAME EVERYDAY 20 1 MIN
24
HOUR E103B 82411 DPST SAME EVERYDAY 20 1 MIN
E120B 82406 SPDT SAME EVERYDAY 20 1 MIN
EW101B 82431 SPST capable of DIFFERENT SCHEDULES 20 1 MIN
7 each day of the week
DAY EW103B 82441 DPST capable of DIFFERENT SCHEDULES 20 1 MIN
each day of the week
EW120B 82436 SPDT capable of DIFFERENT SCHEDULES 20 1 MIN
each day of the week
WIRING DIAGRAMS
E, EW101B SERIES E, EW103B SERIES E, EW103B SERIES E, EW120B SERIES
SPST DPST DPST SPDT
TIMER TIMER TIMER
SUPPLY SUPPLY TIMER
SUPPLY
SUPPLY
1 2 3 4 1 2 3 4 5 6
1 2 3 4 5 6 1 2 3 4 5
LOAD LOAD
LOAD
LOAD LOAD
L N N L N N L N L1 L2 L N N N
120/277VAC 120/277VAC 208 OR 240VAC LOAD 120/277VAC
SERIES E, EW 101B (SPST) DRY CONTACT SPECIFICATION WRITERS GUIDES
SERIES E, EW 103B (DPST) RATINGS Series E100B
1. Furnish and install a TORK digital time switch with (40 Amp SPST contacts,
LOAD TYPE 120VAC 208-277VAC model E101B) (40 Amp DPST contacts, model E103B) (30 Amp SPDT contacts,
model E120B).
Resistive 40A 40A 2. Unit shall be capable of 20 set points.
Inductive 40A 40A 3. Unit shall repeat the same schedule each day.
Ballast 30A 20A WRITE 4-9 AS BELOW
Tungsten 15A Series EW100B
Pilot Duty 720VA 720VA 1. Furnish and install a TORK digital time switch with (40 Amp SPST contacts,
Motor 1HP 112HP@208VAC model EW101B) (40 Amp DPST contacts, model EW103B) (30 Amp SPDT con-
tacts, model EW120B).
2HP@240-277VAC 2. Unit shall be capable of 20 set points.
30A resistive @28VDC 3. Unit shall be capable of a different schedule each day of the week.
WRITE 4-9 AS BELOW
APPLIES TO ALL MODELS:
4. Unit shall have automatic Daylight Savings Time and Leap Year compensation.
DRY CONTACT 5. Unit shall program in AM/PM format.
SERIES E, EW 120B (SPDT) RATINGS 6. Unit shall have LCD display.
120VAC 208-277VAC 7. Unit shall have permanent schedule retention.
8. Unit real time clock shall be retained by supercapacitor for 100 hours in a
LOAD TYPE NO NC NO NC power failure.
Resistive 30A 30A 30A 30A 9. Unit shall be capable of manual override ON or OFF either to the next
scheduled event or permanently.
Inductive 30A 30A 30A 30A 10. Unit shall have a NEMA 3R indoor/outdoor plastic enclosure.
Ballast 30A 10A 20A 10A 11. Unit shall have Load Status indication.
Tungsten 15A 2A 12. Unit shall have Power Failure indication.
Pilot Duty 720VA 720VA 720VA 720VA
Motor 1HP 1HP 112HP@208VAC
2HP@240-277VAC
all NO/NC 30A resistive @28VDC
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
5
ENCLOSURE DIMENSIONS
METAL INDOOR NEMA 1 METAL FLUSH NEMA 1
#68229 Model 9011 Suffix FLG
4-11/16"
8"
AVAILABLE FOR MODELS
STANDARD FOR MODELS DG Series (except DGU,
EH10B, EH20B 7-15/16" DGUM, DGLC)
DZS Series 11" 9-1/8"
TORK
DTS Series
DW Series
DWZ Series
6-1/8"
2-15/16" E Series 4-3/16"
METAL INDOOR/OUTDOOR 5-1/4"
NEMA 3
Model 9000A Suffix O 8-1/4"
METAL INDOOR 5"
NEMA 1 AVAILABLE FOR MODELS
#63100 DW, DWZ, DZS, DTS Series 4-5/8"
E100B Series
STANDARD FOR MODELS 9-1/4" E100PB Series
EW100B
LC200 EWZ Series
LDS-A TORK DG Series
LDSH-A (except DGU,
DGUM, DGLC)
AVAILABLE FOR MODELS
3-3/4"
DW, DWZ, DZS, DTS Series 5"
DG Series NORYL INDOOR/OUTDOOR
NEMA 3R
Model 9000N Suffix N 9-1/8"
STANDARD FOR MODELS
TORK
DG Series DWZ Series
DZS Series SMC-3D
PLASTIC INDOOR PLASTIC INDOOR DTS Series 4-1/2"
NEMA 1 NEMA 1 DW Series
Model 1000P WITH CLEAR WINDOW
Model 1000PC
STANDARD FOR E100PB SERIES AVAILABLE FOR E100PB SERIES
NORYL INDOOR/OUTDOOR
NEMA 3R
5-1/16"
5-1/16"
WITH LEXAN CLEAR WINDOW
Model 9000NC 5"
AVAILABLE FOR MODELS
8-5/16"
8-5/16" DW, DWZ, DZS, DTS Series TORK 9-1/8"
DG Series
3-1/16"
3-1/16" 4-1/2"
5-1/16"
PLASTIC 5-1/16"
PLASTIC
INDOOR/OUTDOOR INDOOR/OUTDOOR
NEMA 3R NEMA 3R
Model 9000P 8-5/16"
WITH CLEAR WINDOW 8-5/16"
Model 9000PC
STANDARD FOR SERIES: AVAILABLE FOR SERIES:
E100B 3-1/16"
E100B
EW100B EW100B 3-1/16"
EWZ101/201/120 EWZ101/201/120
40 A DIVISION OF NSi INDUSTRIES, LLC
ENCLOSURE DIMENSIONS
METAL INDOOR NEMA 1 METAL FLUSH NEMA 1
#68229 Model 9011 Suffix FLG
4-11/16"
8"
AVAILABLE FOR MODELS
STANDARD FOR MODELS DG Series (except DGU,
EH10B, EH20B 7-15/16" DGUM, DGLC)
DZS Series 11" 9-1/8"
TORK
DTS Series
DW Series
DWZ Series
6-1/8"
2-15/16" E Series 4-3/16"
METAL INDOOR/OUTDOOR 5-1/4"
NEMA 3
Model 9000A Suffix O 8-1/4"
METAL INDOOR 5"
NEMA 1 AVAILABLE FOR MODELS
#63100 DW, DWZ, DZS, DTS Series 4-5/8"
E100B Series
STANDARD FOR MODELS 9-1/4" E100PB Series
EW100B
LC200 EWZ Series
LDS-A TORK DG Series
LDSH-A (except DGU,
DGUM, DGLC)
AVAILABLE FOR MODELS
3-3/4"
DW, DWZ, DZS, DTS Series 5"
DG Series NORYL INDOOR/OUTDOOR
NEMA 3R
Model 9000N Suffix N 9-1/8"
STANDARD FOR MODELS
TORK
DG Series DWZ Series
DZS Series SMC-3D
PLASTIC INDOOR PLASTIC INDOOR DTS Series 4-1/2"
NEMA 1 NEMA 1 DW Series
Model 1000P WITH CLEAR WINDOW
Model 1000PC
STANDARD FOR E100PB SERIES AVAILABLE FOR E100PB SERIES
NORYL INDOOR/OUTDOOR
NEMA 3R
5-1/16"
5-1/16"
WITH LEXAN CLEAR WINDOW
Model 9000NC 5"
AVAILABLE FOR MODELS
8-5/16"
8-5/16" DW, DWZ, DZS, DTS Series TORK 9-1/8"
DG Series
3-1/16"
3-1/16" 4-1/2"
5-1/16"
PLASTIC 5-1/16"
PLASTIC
INDOOR/OUTDOOR INDOOR/OUTDOOR
NEMA 3R NEMA 3R
Model 9000P 8-5/16"
WITH CLEAR WINDOW 8-5/16"
Model 9000PC
STANDARD FOR SERIES: AVAILABLE FOR SERIES:
E100B 3-1/16"
E100B
EW100B EW100B 3-1/16"
EWZ101/201/120 EWZ101/201/120
40 A DIVISION OF NSi INDUSTRIES, LLC