HOME 


Product Data

KSCdirect Part #: NSI E120PB
Description: 120V 24HR SUPERCAP INDOOR 1 CH. 20A SPDT
MFG Part #: E120PB
UPC: 78626182469

Your Price: $105.66 / EA

QTY :
* Quantity discounts may be available. Call 800-918-8939.
Alternatively, you may e-mail info@kscdirect.com for service.

Shop our Bargain Bin for closeout specials.


120V 24HR SUPERCAP INDOOR 1 CH. 20A SPDT

NSI / Tork Electrical, Lighting Pool & Spa Products and Replacement Parts

         LEGEND
D DAY
H HOURS
MIL
MO
T
W
MILITARY
MONTH
TOTAL
WEEK
DIGITAL CONTROLS
YR YEAR
P PROGRAMMED E100B E100PB EH
SERIES SERIES 10/20B DG180 DG100 DG120 DWZ100B DW200B DGM100 DGU100 DGUM100 DGS100 DGS180
DC DRY CONTACTS
WC WET CONTACTS
Number of Channels 1 1 1 1 1 1 1 2 1 1 1 1 1

ON/OFF Operations 20 20 20 288 32 32 99 99 32 32 32 32 288

Auto Daylight Savings Adj. Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Removeable
Memory Module

AM/PM/Military Time AM-PM AM-PM AM-PM AM-PM AM-PM AM-PM AM-PM AM-PM AM-PM AM-PM AM-PM AM-PM AM-PM
MIL. MIL. MIL. MIL. MIL. MIL. MIL. MIL. MIL. MIL.

Holidays, Temporary: Special Day Special Day 24 24 Special Day Special Day Special Day Special Day
B = Block Mode Schedule Schedule Schedule Schedule Schedule Schedule

YES TO TO TO TO TO TO TO TO TO TO
Manual Override YES YES INTERNAL NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT NEXT
EXTERNAL EVENT EVENT EVENT EVENT EVENT EVENT EVENT EVENT EVENT EVENT

365 Day / 7 Day Scheduling EW is 7D 7D DAY OMIT 7D 7D 365D 365D 7D 7D 7D 7D DAY OMIT
Momentary (MO) MA MA MA MA MA MA MA MA MO MA MO SIGNAL SIGNAL
[1-2 sec. xed duration] DURATION DURATION
or Maintained (MA) Output

Duty Cycling

Visual Load Status Indicators Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Remote Override UNIVERSAL UNIVERSAL
INPUT INPUT
Service Switches

Automatic Leap Year Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Astronomic Yes

Signal Control: 2 2
Bell, Buzzer, Ring Durations Durations

Skip-A-Day Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Staggered Start

Output Contact: 20A. NO 20A. NO 15A. NO 20A. NO 20A. N.O 15A. NO 20A. NO 15A. NO 20A. NO 20A. NO
Amps Resistive 40A** 30A* 40A 10A. NC 10A. NC 10A. NC 10A. NC 10A. NC 10A. NC 10A. NC 10A. NC 10A. NC 10A. NC

Contact Type: SPST SPST EH10B-SPST SPDT SPDT DPDT SPDT SPDT 2-SPDT SPDT 2-SPDT SPDT SPDT
Dry Unpowered DPST DPST EH20B-DPST
SPDT SPDT
Voltage Input A.C. 24 24 24 24 24 24 24 24 24 24
120 120 120 120 120 120 120 120 120 120 120 120 120
208 VAC 208 208
240 only 240 240 240 240 240 240 240 240 240 240 240
277 277 277 277 277 277 277 277 277
12VDC 12VDC 12VDC 12VDC 12VDC 12VDC 12VDC 12VDC
Battery Back-up: 100H 100H 100H 450H Lithium 450H Lithium 450H Lithium 100H 100H 450H Lithium 275H Lithium 275H Lithium 450H Lithium 450H Lithium
real time rechargeable rechargeable rechargeable 175H Alkaline 175H Alkaline 175H Alkaline rechargeable rechargeable 175H Alkaline 100H Alkaline 100H Alkaline 175H Alkaline 175H Alkaline
SuperCapacitor SuperCapacitor SuperCapacitor SuperCapacitor SuperCapacitor
Schedule retention Permanent Permanent Permanent Permanent Permanent
without power


* E120PB Series 20A. NO - 10A. NC
** E120B Series - 30A




A DIVISION OF NSi INDUSTRIES, LLC
MULTIPURPOSE CONTROLS


E100PB SERIES E101PB/E103PB/E120PB
SUPERCAPACITOR BACKUP!
120VAC 50/60HZ PERMANENT SCHEDULE RETENTION
1 CHANNEL Upgrade from electromechanical to digital with this simple-to-set unit.
E100PB Series gives the advantage of accuracy to-the-minute, an easy to
read display, and supercapacitor backup.
30 amp contacts (SPST, DPST), 20 amp contacts (SPDT) models.
APPLICATIONS:
Signs Air Conditioning Ventilating Fans
Lighting Sump Pumps
FEATURES
SCHEDULING: 24 Hour - same ON/OFF times each day
ON & OFF EVENTS: 20 events
MINIMUM SETTING: 1 minute
DISPLAY: LCD
DAYLIGHT SAVING: Automatic (can be changed or omitted)
LEAP YEAR: Automatic Compensation
MANUAL OVERRIDE: Until the next regularly scheduled ON or
OFF when automatic operation then resumes or permanently if desired.
CLOCK FORMAT: AM/PM
POWER OUTAGE BACKUP: Permanent Schedule Retention. Supercapacitor
maintains real time clock for 100 hours.
SPECIFICATIONS
TIMING ACCURACY: Line Frequency
OPERATING TEMPERATURE: - 40 to +149F (- 40 to +65C.)
WIRING DIAGRAMS STORAGE TEMPERATURE: - 40 to +158F (- 40 to +70C.)
E101PB E103PB RELATIVE HUMIDITY: 0 to 90% RH
E120PB
SPDT
SPST DPST
TIMER TIMER
SUPPLY
ENCLOSURE: Gen. Purpose NEMA 1 plastic is standard
TIMER
SUPPLY
SUPPLY
INPUT VOLTAGE: 120VAC, 50/60Hz
1 2 3 4 1 2 3 4 5 6 POWER CONSUMPTION: 6VA max.
1 2 3
LOAD
4
LOAD
5

OTHER MOUNTINGS:
LOAD
LOAD LOAD Metal Indoor: add sufx Y
L Plastic Indoor with clear cover: add sufx C
N N N
L N N L N N L N
120VAC
120VAC 120VAC Flush with lock and key: add sufx FLG
E120PB
SPDT
Bracket mounting specify mechanism only with bracket
TIMER
SUPPLY
CATALOG UPC DRY SET CLOCK INPUT MIN
1 2 3
LOAD
4
LOAD
5 NO CODE CONTACTS SCHEDULING POINTS 50/60Hz SETTING

LOAD
E101PB 82461 SPST SAME EVERYDAY 20 120VAC 1 MIN
L N N N
120VAC
E103PB 82465 DPST SAME EVERYDAY 20 120VAC 1 MIN
E120PB 82469 SPDT SAME EVERYDAY 20 120VAC 1 MIN

SERIES E101PB (SPST) DRY CONTACT DRY CONTACT
SERIES E103PB (DPST) RATINGS SERIES E120PB (SPDT) RATINGS
120VAC 240VAC 277VAC
LOAD TYPE 120VAC 240VAC 277VAC LOAD TYPE NO NC NO NC NO NC
Resistive 30A 30A 12A Resistive 20A 10A 20A 10A 6A 3A
Inductive 30A 30A 12A Inductive 20A 10A 20A 10A 6A 3A
Ballast 20A 6A 6A Ballast 6A 3A 6A 3A 6A 3A
Tungsten 5A 5A 5A Tungsten 5A 3A 5A 3A
Pilot Duty 470VA 470VA 690VA Pilot Duty 470VA 275VA 470VA 275VA 690VA
Motor 1HP 2HP Motor 1HP 1
4HP 2HP 1
2HP
all are 20A resistive @28VDC NO 20A resistive @ 28VDC, NC 20A resistive @ 28VDC

SPECIFICATION WRITERS GUIDE: E100PB SERIES
1. Furnish and install a TORK digital time switch with (30 Amp SPST contacts, model 6.Unit shall be retained for 100 hours by supercapacitor in a power failure.
E101PB) (30 Amp DPST contacts, model E103PB) (20 Amp SPDT contacts, model 7.Unit shall have LCD display.
E120PB). 8.Unit shall have Permanent Schedule Retention.
2. Unit shall have automatic Daylight Savings Time and Leap Year compensation. 9.Unit shall be capable of manual override ON or OFF either to the next scheduled
3. Unit shall be capable of 20 set points. event or permanently.
4. Unit shall repeat the same schedule each day. 10. Unit shall have a heavy duty General Purpose (NEMA1) non metallic enclosure.
5. Unit shall program in AM/PM format.


6 A DIVISION OF NSi INDUSTRIES, LLC
MULTIPURPOSE CONTROLS


E100PB SERIES E101PB/E103PB/E120PB
SUPERCAPACITOR BACKUP!
120VAC 50/60HZ PERMANENT SCHEDULE RETENTION
1 CHANNEL Upgrade from electromechanical to digital with this simple-to-set unit.
E100PB Series gives the advantage of accuracy to-the-minute, an easy to
read display, and supercapacitor backup.
30 amp contacts (SPST, DPST), 20 amp contacts (SPDT) models.
APPLICATIONS:
Signs Air Conditioning Ventilating Fans
Lighting Sump Pumps
FEATURES
SCHEDULING: 24 Hour - same ON/OFF times each day
ON & OFF EVENTS: 20 events
MINIMUM SETTING: 1 minute
DISPLAY: LCD
DAYLIGHT SAVING: Automatic (can be changed or omitted)
LEAP YEAR: Automatic Compensation
MANUAL OVERRIDE: Until the next regularly scheduled ON or
OFF when automatic operation then resumes or permanently if desired.
CLOCK FORMAT: AM/PM
POWER OUTAGE BACKUP: Permanent Schedule Retention. Supercapacitor
maintains real time clock for 100 hours.
SPECIFICATIONS
TIMING ACCURACY: Line Frequency
OPERATING TEMPERATURE: - 40 to +149F (- 40 to +65C.)
WIRING DIAGRAMS STORAGE TEMPERATURE: - 40 to +158F (- 40 to +70C.)
E101PB E103PB RELATIVE HUMIDITY: 0 to 90% RH
E120PB
SPDT
SPST DPST
TIMER TIMER
SUPPLY
ENCLOSURE: Gen. Purpose NEMA 1 plastic is standard
TIMER
SUPPLY
SUPPLY
INPUT VOLTAGE: 120VAC, 50/60Hz
1 2 3 4 1 2 3 4 5 6 POWER CONSUMPTION: 6VA max.
1 2 3
LOAD
4
LOAD
5

OTHER MOUNTINGS:
LOAD
LOAD LOAD Metal Indoor: add sufx Y
L Plastic Indoor with clear cover: add sufx C
N N N
L N N L N N L N
120VAC
120VAC 120VAC Flush with lock and key: add sufx FLG
E120PB
SPDT
Bracket mounting specify mechanism only with bracket
TIMER
SUPPLY
CATALOG UPC DRY SET CLOCK INPUT MIN
1 2 3
LOAD
4
LOAD
5 NO CODE CONTACTS SCHEDULING POINTS 50/60Hz SETTING

LOAD
E101PB 82461 SPST SAME EVERYDAY 20 120VAC 1 MIN
L N N N
120VAC
E103PB 82465 DPST SAME EVERYDAY 20 120VAC 1 MIN
E120PB 82469 SPDT SAME EVERYDAY 20 120VAC 1 MIN

SERIES E101PB (SPST) DRY CONTACT DRY CONTACT
SERIES E103PB (DPST) RATINGS SERIES E120PB (SPDT) RATINGS
120VAC 240VAC 277VAC
LOAD TYPE 120VAC 240VAC 277VAC LOAD TYPE NO NC NO NC NO NC
Resistive 30A 30A 12A Resistive 20A 10A 20A 10A 6A 3A
Inductive 30A 30A 12A Inductive 20A 10A 20A 10A 6A 3A
Ballast 20A 6A 6A Ballast 6A 3A 6A 3A 6A 3A
Tungsten 5A 5A 5A Tungsten 5A 3A 5A 3A
Pilot Duty 470VA 470VA 690VA Pilot Duty 470VA 275VA 470VA 275VA 690VA
Motor 1HP 2HP Motor 1HP 1
4HP 2HP 1
2HP
all are 20A resistive @28VDC NO 20A resistive @ 28VDC, NC 20A resistive @ 28VDC

SPECIFICATION WRITERS GUIDE: E100PB SERIES
1. Furnish and install a TORK digital time switch with (30 Amp SPST contacts, model 6.Unit shall be retained for 100 hours by supercapacitor in a power failure.
E101PB) (30 Amp DPST contacts, model E103PB) (20 Amp SPDT contacts, model 7.Unit shall have LCD display.
E120PB). 8.Unit shall have Permanent Schedule Retention.
2. Unit shall have automatic Daylight Savings Time and Leap Year compensation. 9.Unit shall be capable of manual override ON or OFF either to the next scheduled
3. Unit shall be capable of 20 set points. event or permanently.
4. Unit shall repeat the same schedule each day. 10. Unit shall have a heavy duty General Purpose (NEMA1) non metallic enclosure.
5. Unit shall program in AM/PM format.


6 A DIVISION OF NSi INDUSTRIES, LLC
MULTIPURPOSE CONTROLS


E100PB SERIES E101PB/E103PB/E120PB
SUPERCAPACITOR BACKUP!
120VAC 50/60HZ PERMANENT SCHEDULE RETENTION
1 CHANNEL Upgrade from electromechanical to digital with this simple-to-set unit.
E100PB Series gives the advantage of accuracy to-the-minute, an easy to
read display, and supercapacitor backup.
30 amp contacts (SPST, DPST), 20 amp contacts (SPDT) models.
APPLICATIONS:
Signs Air Conditioning Ventilating Fans
Lighting Sump Pumps
FEATURES
SCHEDULING: 24 Hour - same ON/OFF times each day
ON & OFF EVENTS: 20 events
MINIMUM SETTING: 1 minute
DISPLAY: LCD
DAYLIGHT SAVING: Automatic (can be changed or omitted)
LEAP YEAR: Automatic Compensation
MANUAL OVERRIDE: Until the next regularly scheduled ON or
OFF when automatic operation then resumes or permanently if desired.
CLOCK FORMAT: AM/PM
POWER OUTAGE BACKUP: Permanent Schedule Retention. Supercapacitor
maintains real time clock for 100 hours.
SPECIFICATIONS
TIMING ACCURACY: Line Frequency
OPERATING TEMPERATURE: - 40 to +149F (- 40 to +65C.)
WIRING DIAGRAMS STORAGE TEMPERATURE: - 40 to +158F (- 40 to +70C.)
E101PB E103PB RELATIVE HUMIDITY: 0 to 90% RH
E120PB
SPDT
SPST DPST
TIMER TIMER
SUPPLY
ENCLOSURE: Gen. Purpose NEMA 1 plastic is standard
TIMER
SUPPLY
SUPPLY
INPUT VOLTAGE: 120VAC, 50/60Hz
1 2 3 4 1 2 3 4 5 6 POWER CONSUMPTION: 6VA max.
1 2 3
LOAD
4
LOAD
5

OTHER MOUNTINGS:
LOAD
LOAD LOAD Metal Indoor: add sufx Y
L Plastic Indoor with clear cover: add sufx C
N N N
L N N L N N L N
120VAC
120VAC 120VAC Flush with lock and key: add sufx FLG
E120PB
SPDT
Bracket mounting specify mechanism only with bracket
TIMER
SUPPLY
CATALOG UPC DRY SET CLOCK INPUT MIN
1 2 3
LOAD
4
LOAD
5 NO CODE CONTACTS SCHEDULING POINTS 50/60Hz SETTING

LOAD
E101PB 82461 SPST SAME EVERYDAY 20 120VAC 1 MIN
L N N N
120VAC
E103PB 82465 DPST SAME EVERYDAY 20 120VAC 1 MIN
E120PB 82469 SPDT SAME EVERYDAY 20 120VAC 1 MIN

SERIES E101PB (SPST) DRY CONTACT DRY CONTACT
SERIES E103PB (DPST) RATINGS SERIES E120PB (SPDT) RATINGS
120VAC 240VAC 277VAC
LOAD TYPE 120VAC 240VAC 277VAC LOAD TYPE NO NC NO NC NO NC
Resistive 30A 30A 12A Resistive 20A 10A 20A 10A 6A 3A
Inductive 30A 30A 12A Inductive 20A 10A 20A 10A 6A 3A
Ballast 20A 6A 6A Ballast 6A 3A 6A 3A 6A 3A
Tungsten 5A 5A 5A Tungsten 5A 3A 5A 3A
Pilot Duty 470VA 470VA 690VA Pilot Duty 470VA 275VA 470VA 275VA 690VA
Motor 1HP 2HP Motor 1HP 1
4HP 2HP 1
2HP
all are 20A resistive @28VDC NO 20A resistive @ 28VDC, NC 20A resistive @ 28VDC

SPECIFICATION WRITERS GUIDE: E100PB SERIES
1. Furnish and install a TORK digital time switch with (30 Amp SPST contacts, model 6.Unit shall be retained for 100 hours by supercapacitor in a power failure.
E101PB) (30 Amp DPST contacts, model E103PB) (20 Amp SPDT contacts, model 7.Unit shall have LCD display.
E120PB). 8.Unit shall have Permanent Schedule Retention.
2. Unit shall have automatic Daylight Savings Time and Leap Year compensation. 9.Unit shall be capable of manual override ON or OFF either to the next scheduled
3. Unit shall be capable of 20 set points. event or permanently.
4. Unit shall repeat the same schedule each day. 10. Unit shall have a heavy duty General Purpose (NEMA1) non metallic enclosure.
5. Unit shall program in AM/PM format.


6 A DIVISION OF NSi INDUSTRIES, LLC
MULTIPURPOSE CONTROLS


E100PB SERIES E101PB/E103PB/E120PB
SUPERCAPACITOR BACKUP!
120VAC 50/60HZ PERMANENT SCHEDULE RETENTION
1 CHANNEL Upgrade from electromechanical to digital with this simple-to-set unit.
E100PB Series gives the advantage of accuracy to-the-minute, an easy to
read display, and supercapacitor backup.
30 amp contacts (SPST, DPST), 20 amp contacts (SPDT) models.
APPLICATIONS:
Signs Air Conditioning Ventilating Fans
Lighting Sump Pumps
FEATURES
SCHEDULING: 24 Hour - same ON/OFF times each day
ON & OFF EVENTS: 20 events
MINIMUM SETTING: 1 minute
DISPLAY: LCD
DAYLIGHT SAVING: Automatic (can be changed or omitted)
LEAP YEAR: Automatic Compensation
MANUAL OVERRIDE: Until the next regularly scheduled ON or
OFF when automatic operation then resumes or permanently if desired.
CLOCK FORMAT: AM/PM
POWER OUTAGE BACKUP: Permanent Schedule Retention. Supercapacitor
maintains real time clock for 100 hours.
SPECIFICATIONS
TIMING ACCURACY: Line Frequency
OPERATING TEMPERATURE: - 40 to +149F (- 40 to +65C.)
WIRING DIAGRAMS STORAGE TEMPERATURE: - 40 to +158F (- 40 to +70C.)
E101PB E103PB RELATIVE HUMIDITY: 0 to 90% RH
E120PB
SPDT
SPST DPST
TIMER TIMER
SUPPLY
ENCLOSURE: Gen. Purpose NEMA 1 plastic is standard
TIMER
SUPPLY
SUPPLY
INPUT VOLTAGE: 120VAC, 50/60Hz
1 2 3 4 1 2 3 4 5 6 POWER CONSUMPTION: 6VA max.
1 2 3
LOAD
4
LOAD
5

OTHER MOUNTINGS:
LOAD
LOAD LOAD Metal Indoor: add sufx Y
L Plastic Indoor with clear cover: add sufx C
N N N
L N N L N N L N
120VAC
120VAC 120VAC Flush with lock and key: add sufx FLG
E120PB
SPDT
Bracket mounting specify mechanism only with bracket
TIMER
SUPPLY
CATALOG UPC DRY SET CLOCK INPUT MIN
1 2 3
LOAD
4
LOAD
5 NO CODE CONTACTS SCHEDULING POINTS 50/60Hz SETTING

LOAD
E101PB 82461 SPST SAME EVERYDAY 20 120VAC 1 MIN
L N N N
120VAC
E103PB 82465 DPST SAME EVERYDAY 20 120VAC 1 MIN
E120PB 82469 SPDT SAME EVERYDAY 20 120VAC 1 MIN

SERIES E101PB (SPST) DRY CONTACT DRY CONTACT
SERIES E103PB (DPST) RATINGS SERIES E120PB (SPDT) RATINGS
120VAC 240VAC 277VAC
LOAD TYPE 120VAC 240VAC 277VAC LOAD TYPE NO NC NO NC NO NC
Resistive 30A 30A 12A Resistive 20A 10A 20A 10A 6A 3A
Inductive 30A 30A 12A Inductive 20A 10A 20A 10A 6A 3A
Ballast 20A 6A 6A Ballast 6A 3A 6A 3A 6A 3A
Tungsten 5A 5A 5A Tungsten 5A 3A 5A 3A
Pilot Duty 470VA 470VA 690VA Pilot Duty 470VA 275VA 470VA 275VA 690VA
Motor 1HP 2HP Motor 1HP 1
4HP 2HP 1
2HP
all are 20A resistive @28VDC NO 20A resistive @ 28VDC, NC 20A resistive @ 28VDC

SPECIFICATION WRITERS GUIDE: E100PB SERIES
1. Furnish and install a TORK digital time switch with (30 Amp SPST contacts, model 6.Unit shall be retained for 100 hours by supercapacitor in a power failure.
E101PB) (30 Amp DPST contacts, model E103PB) (20 Amp SPDT contacts, model 7.Unit shall have LCD display.
E120PB). 8.Unit shall have Permanent Schedule Retention.
2. Unit shall have automatic Daylight Savings Time and Leap Year compensation. 9.Unit shall be capable of manual override ON or OFF either to the next scheduled
3. Unit shall be capable of 20 set points. event or permanently.
4. Unit shall repeat the same schedule each day. 10. Unit shall have a heavy duty General Purpose (NEMA1) non metallic enclosure.
5. Unit shall program in AM/PM format.


6 A DIVISION OF NSi INDUSTRIES, LLC
MULTIPURPOSE CONTROLS


E100PB SERIES E101PB/E103PB/E120PB
SUPERCAPACITOR BACKUP!
120VAC 50/60HZ PERMANENT SCHEDULE RETENTION
1 CHANNEL Upgrade from electromechanical to digital with this simple-to-set unit.
E100PB Series gives the advantage of accuracy to-the-minute, an easy to
read display, and supercapacitor backup.
30 amp contacts (SPST, DPST), 20 amp contacts (SPDT) models.
APPLICATIONS:
Signs Air Conditioning Ventilating Fans
Lighting Sump Pumps
FEATURES
SCHEDULING: 24 Hour - same ON/OFF times each day
ON & OFF EVENTS: 20 events
MINIMUM SETTING: 1 minute
DISPLAY: LCD
DAYLIGHT SAVING: Automatic (can be changed or omitted)
LEAP YEAR: Automatic Compensation
MANUAL OVERRIDE: Until the next regularly scheduled ON or
OFF when automatic operation then resumes or permanently if desired.
CLOCK FORMAT: AM/PM
POWER OUTAGE BACKUP: Permanent Schedule Retention. Supercapacitor
maintains real time clock for 100 hours.
SPECIFICATIONS
TIMING ACCURACY: Line Frequency
OPERATING TEMPERATURE: - 40 to +149F (- 40 to +65C.)
WIRING DIAGRAMS STORAGE TEMPERATURE: - 40 to +158F (- 40 to +70C.)
E101PB E103PB RELATIVE HUMIDITY: 0 to 90% RH
E120PB
SPDT
SPST DPST
TIMER TIMER
SUPPLY
ENCLOSURE: Gen. Purpose NEMA 1 plastic is standard
TIMER
SUPPLY
SUPPLY
INPUT VOLTAGE: 120VAC, 50/60Hz
1 2 3 4 1 2 3 4 5 6 POWER CONSUMPTION: 6VA max.
1 2 3
LOAD
4
LOAD
5

OTHER MOUNTINGS:
LOAD
LOAD LOAD Metal Indoor: add sufx Y
L Plastic Indoor with clear cover: add sufx C
N N N
L N N L N N L N
120VAC
120VAC 120VAC Flush with lock and key: add sufx FLG
E120PB
SPDT
Bracket mounting specify mechanism only with bracket
TIMER
SUPPLY
CATALOG UPC DRY SET CLOCK INPUT MIN
1 2 3
LOAD
4
LOAD
5 NO CODE CONTACTS SCHEDULING POINTS 50/60Hz SETTING

LOAD
E101PB 82461 SPST SAME EVERYDAY 20 120VAC 1 MIN
L N N N
120VAC
E103PB 82465 DPST SAME EVERYDAY 20 120VAC 1 MIN
E120PB 82469 SPDT SAME EVERYDAY 20 120VAC 1 MIN

SERIES E101PB (SPST) DRY CONTACT DRY CONTACT
SERIES E103PB (DPST) RATINGS SERIES E120PB (SPDT) RATINGS
120VAC 240VAC 277VAC
LOAD TYPE 120VAC 240VAC 277VAC LOAD TYPE NO NC NO NC NO NC
Resistive 30A 30A 12A Resistive 20A 10A 20A 10A 6A 3A
Inductive 30A 30A 12A Inductive 20A 10A 20A 10A 6A 3A
Ballast 20A 6A 6A Ballast 6A 3A 6A 3A 6A 3A
Tungsten 5A 5A 5A Tungsten 5A 3A 5A 3A
Pilot Duty 470VA 470VA 690VA Pilot Duty 470VA 275VA 470VA 275VA 690VA
Motor 1HP 2HP Motor 1HP 1
4HP 2HP 1
2HP
all are 20A resistive @28VDC NO 20A resistive @ 28VDC, NC 20A resistive @ 28VDC

SPECIFICATION WRITERS GUIDE: E100PB SERIES
1. Furnish and install a TORK digital time switch with (30 Amp SPST contacts, model 6.Unit shall be retained for 100 hours by supercapacitor in a power failure.
E101PB) (30 Amp DPST contacts, model E103PB) (20 Amp SPDT contacts, model 7.Unit shall have LCD display.
E120PB). 8.Unit shall have Permanent Schedule Retention.
2. Unit shall have automatic Daylight Savings Time and Leap Year compensation. 9.Unit shall be capable of manual override ON or OFF either to the next scheduled
3. Unit shall be capable of 20 set points. event or permanently.
4. Unit shall repeat the same schedule each day. 10. Unit shall have a heavy duty General Purpose (NEMA1) non metallic enclosure.
5. Unit shall program in AM/PM format.


6 A DIVISION OF NSi INDUSTRIES, LLC
MULTIPURPOSE CONTROLS


E100PB SERIES E101PB/E103PB/E120PB
SUPERCAPACITOR BACKUP!
120VAC 50/60HZ PERMANENT SCHEDULE RETENTION
1 CHANNEL Upgrade from electromechanical to digital with this simple-to-set unit.
E100PB Series gives the advantage of accuracy to-the-minute, an easy to
read display, and supercapacitor backup.
30 amp contacts (SPST, DPST), 20 amp contacts (SPDT) models.
APPLICATIONS:
Signs Air Conditioning Ventilating Fans
Lighting Sump Pumps
FEATURES
SCHEDULING: 24 Hour - same ON/OFF times each day
ON & OFF EVENTS: 20 events
MINIMUM SETTING: 1 minute
DISPLAY: LCD
DAYLIGHT SAVING: Automatic (can be changed or omitted)
LEAP YEAR: Automatic Compensation
MANUAL OVERRIDE: Until the next regularly scheduled ON or
OFF when automatic operation then resumes or permanently if desired.
CLOCK FORMAT: AM/PM
POWER OUTAGE BACKUP: Permanent Schedule Retention. Supercapacitor
maintains real time clock for 100 hours.
SPECIFICATIONS
TIMING ACCURACY: Line Frequency
OPERATING TEMPERATURE: - 40 to +149F (- 40 to +65C.)
WIRING DIAGRAMS STORAGE TEMPERATURE: - 40 to +158F (- 40 to +70C.)
E101PB E103PB RELATIVE HUMIDITY: 0 to 90% RH
E120PB
SPDT
SPST DPST
TIMER TIMER
SUPPLY
ENCLOSURE: Gen. Purpose NEMA 1 plastic is standard
TIMER
SUPPLY
SUPPLY
INPUT VOLTAGE: 120VAC, 50/60Hz
1 2 3 4 1 2 3 4 5 6 POWER CONSUMPTION: 6VA max.
1 2 3
LOAD
4
LOAD
5

OTHER MOUNTINGS:
LOAD
LOAD LOAD Metal Indoor: add sufx Y
L Plastic Indoor with clear cover: add sufx C
N N N
L N N L N N L N
120VAC
120VAC 120VAC Flush with lock and key: add sufx FLG
E120PB
SPDT
Bracket mounting specify mechanism only with bracket
TIMER
SUPPLY
CATALOG UPC DRY SET CLOCK INPUT MIN
1 2 3
LOAD
4
LOAD
5 NO CODE CONTACTS SCHEDULING POINTS 50/60Hz SETTING

LOAD
E101PB 82461 SPST SAME EVERYDAY 20 120VAC 1 MIN
L N N N
120VAC
E103PB 82465 DPST SAME EVERYDAY 20 120VAC 1 MIN
E120PB 82469 SPDT SAME EVERYDAY 20 120VAC 1 MIN

SERIES E101PB (SPST) DRY CONTACT DRY CONTACT
SERIES E103PB (DPST) RATINGS SERIES E120PB (SPDT) RATINGS
120VAC 240VAC 277VAC
LOAD TYPE 120VAC 240VAC 277VAC LOAD TYPE NO NC NO NC NO NC
Resistive 30A 30A 12A Resistive 20A 10A 20A 10A 6A 3A
Inductive 30A 30A 12A Inductive 20A 10A 20A 10A 6A 3A
Ballast 20A 6A 6A Ballast 6A 3A 6A 3A 6A 3A
Tungsten 5A 5A 5A Tungsten 5A 3A 5A 3A
Pilot Duty 470VA 470VA 690VA Pilot Duty 470VA 275VA 470VA 275VA 690VA
Motor 1HP 2HP Motor 1HP 1
4HP 2HP 1
2HP
all are 20A resistive @28VDC NO 20A resistive @ 28VDC, NC 20A resistive @ 28VDC

SPECIFICATION WRITERS GUIDE: E100PB SERIES
1. Furnish and install a TORK digital time switch with (30 Amp SPST contacts, model 6.Unit shall be retained for 100 hours by supercapacitor in a power failure.
E101PB) (30 Amp DPST contacts, model E103PB) (20 Amp SPDT contacts, model 7.Unit shall have LCD display.
E120PB). 8.Unit shall have Permanent Schedule Retention.
2. Unit shall have automatic Daylight Savings Time and Leap Year compensation. 9.Unit shall be capable of manual override ON or OFF either to the next scheduled
3. Unit shall be capable of 20 set points. event or permanently.
4. Unit shall repeat the same schedule each day. 10. Unit shall have a heavy duty General Purpose (NEMA1) non metallic enclosure.
5. Unit shall program in AM/PM format.


6 A DIVISION OF NSi INDUSTRIES, LLC
ALPHANUMERIC INDEX TERMS OF SALE
CATALOG TORK VENDOR NUMBER: 786261
NUMBER PAGE
1. Prices are F.O.B. our plant.
451D . . . . . . . . . . . . . . . . . . . . . 36 2. Prices do not include any sales tax.
631D . . . . . . . . . . . . . . . . . . . . . 36 3. Freight charges will be prepaid on all orders $250.00 and over
653A, 654A . . . . . . . . . . . . . . . . 36 shipping within continental USA using standard shipping meth-
5401, 5440, 5441 . . . . . . . . . . . 37 ods and service.
90058-1 . . . . . . . . . . . . . . . . . . 38 4. Minimum order $100.00.
5. Claims for shortage, erroneous charges or price corrections shall
ACT . . . . . . . . . . . . . . . . . . . 30,31
be deemed waived unless made in writing, delivered to NSi
DG, DGM . . . . . . . . . . . . . . . 10,11
within 30 days of invoice.
DGLC . . . . . . . . . . . . . . . . . . 14,15
6. Terms of payment 2% 10th prox. net 25th following.
DGU, DGUM . . . . . . . . . . . . . 12,13
7. Warranties NSi guarantees all products to be free of defects in
DGS . . . . . . . . . . . . . . . . . . . . . . 9
material and workmanship for a period of 1 year from date of
DIN . . . . . . . . . . . . . . . . . . . . . . . 3
sale. Any claims for defective material must be agreed to in
DLC400BP . . . . . . . . . . . . . . . 22,23 writing by NSi. Defective material will be replaced on an F.O.B.
DTS . . . . . . . . . . . . . . . . . . . . 18,19 our factory basis. NSi disclaims the implied warranty of tness
DW, DWZ . . . . . . . . . . . . . . . 20,21 for a particular application.
DZS . . . . . . . . . . . . . . . . . . . 16,17
DZM . . . . . . . . . . . . . . . . . . . . . 24
E101B, E103B, E120B . . . . . . . . 4,5 OTHER PRODUCTS AVAILABLE
E101PB, E103PB, E120PB . . . . . . . 6
EH . . . . . . . . . . . . . . . . . . . . . . . . 8 NSi can provide many other products for special applications which
EW . . . . . . . . . . . . . . . . . . . . . .4,5 are not listed in this catalog. If you require an item which you do
EWZ . . . . . . . . . . . . . . . . . . . . . . 7 not nd listed, please contact us. We would be pleased to provide a
HPS . . . . . . . . . . . . . . . . . . . . . . 38 quotation upon receipt of a drawing or a sample.
K . . . . . . . . . . . . . . . . . . . . . . . . 25
LC . . . . . . . . . . . . . . . . . . . . . . . 28
MMP . . . . . . . . . . . . . . .16, 23, 24 GUARANTEE
SMC . . . . . . . . . . . . . . . . . . 29
SS . . . . . . . . . . . . . . . . . . 34 It is our goal to provide extraordinary products and service on a
SS700Z . . . . . . . . . . . . . 35 daily basis. If our products or service do not meet with your satis-
SS720A . . . . . . . . . . . . 35 faction, please let us know immediately and we promise to make
SSA . . . . . . . . . . . . 32,33 every reasonable effort to remedy the situation.
TRP . . . . . . . . . . . . . . . 38




41
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC




Powered by Venture
Open Source ERP Software