HOME 


Product Data

KSCdirect Part #: NSI 9005
Description: FLUSH ENCLOSURE FOR ALL T SERIES,W300, W300L
MFG Part #: 9005
UPC: 78626194007

Your Price: $151.79 / EA

QTY :
* Quantity discounts may be available. Call 800-918-8939.
Alternatively, you may e-mail info@kscdirect.com for service.

Shop our Bargain Bin for closeout specials.


FLUSH ENCLOSURE FOR ALL T SERIES,W300, W300L

NSI / Tork Electrical, Lighting Pool & Spa Products and Replacement Parts

            CAT                UPC                                                                                                               H.P.     MOTOR:      MOTOR:
NO CODE ENCLOSURE TYPE SWITCH AMPS RATING AC VOLTAGE Hz

7100 10001 Metal Indoor SPST 40 2 120 60
7102 10002 Metal Indoor SPST 40 5 208-277 60
7200 11001 Metal Indoor DPST 40 2 120 60
7202 11002 Metal Indoor DPST 40 5 208-277 60
7300 12001 Metal Indoor/Outdoor 3PST 40 2 120 60
7302 12002 Metal Indoor/Outdoor 3PST 40 5 208-277 60
7120 13001 Metal Indoor SPDT 40 2 120 60
7122 13002 Metal Indoor SPDT 40 5 208-277 60
7220 14001 Metal Indoor DPDT 40 2 120 60
7222 14002 Metal Indoor DPDT 40 5 208-277 60

WITH RESERVE POWER
7200L 19003 Noryl Indoor/Outdoor DPST 40 2 120 60
7202L 19004 Noryl Indoor/Outdoor DPST 40 5 208-277 60
7300L 19005 Metal Indoor/Outdoor 3PST 40 2 120 60
7302L 19006 Metal Indoor/Outdoor 3PST 40 5 208-277 60
7120L 19007 Noryl Indoor/Outdoor SPDT 40 2 120 60
7220L 19009 Noryl Indoor/Outdoor DPDT 40 2 120 60
7222L 19011 Noryl Indoor/Outdoor DPDT 40 5 208-277 60

CONVERSION NOTE: ORDER ZKIT: Astronomic kit for eld conversion of TORK 7000 and 1100 SERIES
24 VOLT IN ALL MODELS AVAILABLE ON SPECIFICATION. Indoor/outdoor Noryl case is standard on all models with reserve power except 3PST is metal
indoor/outdoor.
NOTE 1: If converting to reserve power in the eld, order Model 63100 enclosure to accommodate the larger unit (not necessary with 3PST models)
NOTE 2. When replacing a Model 7300 or 7302 mechanism only into an existing enclosure, order CK7300 conversion kit since the new mechanism is designed
narrower than the old one.


WIRING DIAGRAMS
7100 SPST 7200 DPST 7300 3PST

M M M



L 1 X 2
L 1 X 2
L 2 L
3 4

H LOAD L
LOAD LOAD
N H 5 6
N L
LOAD LOAD LOAD
H
N




7120 SPDT 7220 DPDT

M
M




L 1 X 2 H
L 1 X 2
H LOAD
H
H N
LOAD LOAD
A B L 3 5 4 LOAD



N N LOAD LOAD
H
N
N




SPECIFICATION WRITERS GUIDE 7000 SERIES
Furnish and install where shown a TORK Time Switch with 24 hour dial and day-omitting device. The Time Switch shall be powered by a self-starting synchronous motor.
Time Switch contacts shall be capable of switching 40 amperes per pole continuously at 277 volts and shall be SPST (DPST, 3PST, DPST, SPDT, as required). Removable ON-
OFF trippers shall make possible automatic operation with a minimum ON period of 20 minutes and a minimum of 2 hours between one OFF period and the next. Enclosure
shall be NEMA 1 surface type, nished in beige enamel, with combination 1/2, 3/4 knockouts on bottom, both sides and back. Provision shall be made for positive pad-
locking. Terminals shall be capable of receiving #8 AWG wire. Time Switch shall be TORK Model 7_ _ _ (to t requirement).

FOR RESERVE POWER (MODELS WITH SUFFIX L): Spring-driven reserve shall be provided sufcient to operate the Time Switch contacts at least 16 hours after power fail-
ure. On restoration of power, Time Switch shall transfer to synchronous motor drive and automatically rewind reserve power unit.



5
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
CAT UPC MOTOR: MOTOR: ENCLOSURE
NO CODE SWITCH AMPS AC VOLTAGE Hz TYPE

7200Z 21001 DPST 40 120 60 Noryl Indoor/Outdoor
7202Z 21002 DPST 40 208-277 60 Noryl Indoor/Outdoor
7300Z 22001 3PST 40 120 60 Metal Indoor/Outdoor
7302Z 22002 3PST 40 208-277 60 Metal Indoor/Outdoor
7120Z 23001 SPDT 40 120 60 Noryl Indoor/Outdoor

WITH RESERVE POWER
7200ZL 29003 DPST 40 120 60 Noryl Indoor/Outdoor
7202ZL 29013 DPST 40 208-277 60 Noryl Indoor/Outdoor
7300ZL 29005 3PST 40 120 60 Metal Indoor/Outdoor
7302ZL 29015 3PST 40 208-277 60 Metal Indoor/Outdoor
7120ZL 29007 SPDT 40 120 60 Noryl Indoor/Outdoor
7122ZL 29017 SPDT 40 208-277 60 Noryl Indoor/Outdoor


24 VOLT IN ALL MODELS AVAILABLE ON SPECIFICATION.
NOTE 1: When replacing a Model 7300 or 7302 mechanism only into an existing enclosure, order CK7300 conversion kit since the new mechanism is designed
narrower than the old one.




WIRING DIAGRAMS

7200Z (DPST) 7300Z (3PST) 7120Z (SPDT)
M M M



L 1 X 2
L 1 X 2
L
L 1 X 2
3 4
N
LOAD LOAD L H
H LOAD LOAD
5 6 A B
N
L
H LOAD LOAD LOAD N H
N

FOR USE WITH 3 PHASE 4-WIRE
120/208V SYSTEMS.




SPECIFICATION WRITERS GUIDE 7000Z SERIES
Furnish and install where shown a TORK Time Switch with Astronomic dial and day-omitting device powered by a self-starting synchronous motor. Time Switch contacts shall
be capable of switching 40 amperes per pole continuously at 277 volts and shall be (DPST, 3PST or SPDT) as required. ON operation shall occur automatically at sunset (in
city of use). OFF operation shall be adjustable from 8:30 P.M. to 2:30 A.M. in one-half hour increments or at sunrise. Both ON and OFF shall have a range of adjustabili-
ty of 20-40 minutes before or after sunset and sunrise. Enclosure shall be: DPST or SPDT is NEMA 3R indoor/outdoor Noryl 3PST is NEMA 3 metal indoor/outdoor.
Terminals shall be of the pressure type, capable of receiving #8 AWG wire. Time Switch shall be TORK Model 7_ _ _Z (to t requirement).

FOR RESERVE POWER (Add Sufx L): Spring driven reserve shall be provided sufcient to operate the Time Switch contacts at least 16 hours after power failure. On restora-
tion of power, Time Switch shall transfer to synchronous motor drive and automatically rewind reserve power unit.




9
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
W SERIES
7 DAY TIME SWITCHES
DIFFERENT SCHEDULES EACH DAY

APPLICATIONS
Heating Air Conditioning Display Lighting
Ventilating Lighted Signs Storefront Lighting

SPDT switches provide for control of mechanically-held contactors.



SPECIFICATIONS
Offers the easiest and most accurate setting of any 7 day
Time Switch by means of unique combination ON-OFF trippers,
distinctive time indicator and trigger action switch tripping
mechanism.

CONTACT RATINGS:
40 Amp. Tungsten, 120 VAC
40 Amp. Resistive, 120-277 VAC Single Phase
40 Amp. General Purpose, 120-277 VAC Single Phase
20 Amp. Inductive 120 VAC, 277 VAC Single Phase
1000 VA Pilot Duty 120-277 VAC.
2 HP (24 FLA) 120 VAC; 5 HP (28 FLA) 240 VAC

TIMING MOTOR: Heavy duty synchronous, self-starting high torque. Power W SERIES
Consumption: 3 watts.

OPTIONAL RESERVE POWER: Keeps dial on time up to 24 hours during power outage (16 hours on 4PST models).
Add sufx L to model number. Power Consumption: 5 watts.

AUTOMATIC OPERATION: Minimum ON setting: 1 Hour. Minimum OFF setting: 2 Hours. (8 hours between 2 OFF
settings). Models W400A and W402A offer minimum ON/OFF settings of 312 hours. 7 day calendar dial
accommodates up to 2 pairs of ON-OFF removable Trippers per day 7 pairs are supplied.
Dial markings in English, French & Spanish.

TEMPORARY MANUAL OVERRIDE: Standard.

OPERATING TEMPERATURE RANGE: -40 to +165F. (-40 to +74C.)

ENCLOSURE: See page 27 for dimensions. Surface: General Purpose (NEMA 1). Deep-drawn Steel, beige enamel, lock-
able hasp, with combination 12 & 34 K.O.s on both sides and bottom.

OTHER MOUNTINGS: *When ordering special enclosures ONLY, please use model number.
Indoor /Outdoor Metal NEMA Type 3 (Sufx O) Model 9006*
Flush Mount with lock and key NEMA Type 1: (sufx FL5) Model 9005*
Bracket mounting specify mechanism only with bracket.




14
A DIVISION OF NSi INDUSTRIES, LLC
CAT UPC HP MOTOR: FREQUENCY
NO CODE SWITCH AMPS RATING AC VOLTAGE Hz

W100 30001 SPST 40 2 120 60
W200 31001 DPST 40 2 120 60
W202 31011 DPST 40 5 208-277 60
W300 32001 3PST 40 2 120 60
W302 32002 3PST 40 5 208-277 60
W120 33001 SPDT 40 2 120 60
W220 34001 DPDT 40 2 120 60
W222 34011 DPDT 40 5 208-277 60
W400A 35001 4PST 40 2 120 60
W402A 35002 4PST 40 5 208-277 60

WITH RESERVE POWER
W300L 39005 3PST 40 2 120 60
W302L 39006 3PST 40 5 208-277 60
W220L 39009 DPDT 40 2 120 60
W222L 39010 DPDT 40 5 208-277 60
W400AL 39007 4PST 40 2 120 60
24 VOLT IN ALL MODELS AVAILABLE ON SPECIFICATION.




WIRING DIAGRAMS
W100 (SPST) W200 (DPST) W300 (3PST) W120 (SPDT) W220 (DPDT)
M M
M M M

L 1 X 2

L 1 X 2 H
L 1 X 2
L
3 4 L 1 X 2 H LOAD
L 2
H N
LOAD LOAD
L H
H H 5 6 LOAD LOAD L 3
LOAD 5 4 LOAD
N A B
N L
H LOAD LOAD LOAD N LOAD LOAD
H
N
N N
N


W400A (4PST)
Equipment
Ground M

A 1 2 3 4


Clock Motor
Supply
5 6 7 8

B




Supply
To Load(s)




SPECIFICATION WRITERS GUIDE W SERIES
Furnish and install where shown TORK Time Switch of the 7 day type, powered by a self-starting synchronous motor, capable of being set for different ON-OFF times each
day of the week, to an operating accuracy of plus or minus 15 minutes of the desired time. Time Switch contacts shall be capable of switching 40 amperes per pole contin-
uously at 277 volts and shall be SPST (DPST, 3PST, DPDT, SPDT, 4PST as required). Removable ON-OFF trippers shall make possible automatic operation with a minimum
ON period of one hour and a minimum of 2 hours between one OFF operation and the next ON. Models W400 and W402 offer minimum ON and OFF settings of 3-1/2
hours. Enclosure shall be NEMA 1 surface, nished in baked beige enamel, with combination 1/2 - 3/4 knock-outs on bottom and both sides. Provision shall be made for
positive padlocking. Terminals shall be capable of receiving #8 AWG wire. Time Switch shall be TORK Model W_ _ _ (to t requirement).
FOR RESERVE POWER (Add sufx L): Spring-driven reserve shall be provided sufcient to operate the Time Switch contacts at least 24 hours after power failure (16 hour
reserve power on 4PST models). On restoration of power, Time Switch shall transfer to synchronous motor driven and automatically rewind reserve power unit.




15
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
TW SERIES
7 DAY TIME SWITCHES
DIFFERENT SCHEDULES EACH DAY
WITH MANUAL BYPASS SWITCHES
RESERVE POWER STANDARD

APPLICATIONS
Heating Air Conditioning Display Lighting
Ventilating Lighted Signs Storefront Lighting

NOTE: All models are designed to control a contactor
circuit and not recommended for direct switching of
most lighting loads.

SPECIFICATIONS
CONTACT RATINGS: Tungsten rated at 277V.
20 Amps per circuit,
2 HP at 120V, 5 HP at 240V.

MANUAL BY-PASS SWITCHES: Single pole, 20 Amps one per circuit.
Factory prewired to terminal strip.
ON-OFF-AUTO positions for each circuit is independent will not
disturb automatic settings.
TW SERIES
TIMING MOTOR: Heavy duty self-starting, synchronous motor with 24 hour
spring driven Reserve Power standard. Power Consumption: 5 watts.

AUTOMATIC OPERATION: Minimum ON setting: 1 Hour. Minimum OFF setting:
2 Hours. 7 day calendar dial accommodates up to 2 pairs of ON-OFF
removable Trippers per day 7 pairs are supplied. OPTIONAL
E COVER
OPERATING TEMPERATURE RANGE: -40 to +165F. (-40 to +74C.)

ENCLOSURE: See page 27 for dimensions. General Purpose (NEMA 1), beige enamel, lockable hasp, with combination
1
2 & 34 K.O.s on both sides and bottom. Optional E door [specify) available to replace standard removeable cover
when access to external by--pass switches is required.

OTHER MOUNTINGS: *When ordering special enclosures ONLY, please use model number.
Indoor /Outdoor Metal NEMA Type 3 (Sufx O) Model 9006*
Flush Mount with lock and key NEMA Type 1: (sufx FL5) Model 9005*




CAT UPC H.P MOTOR MOTOR: MOTOR
NO CODE SWITCH AMPS RATING AC VOLTAGE Hz PART NO

TW-220L 39013 DPDT 20 2 120 60 36
TW-222L 39014 DPDT 20 5 208-277 60 46
TW-300L 39015 3PST 20 2 120 60 36
TW-302L 39016 3PST 20 5 208-277 60 46

24 VOLT IN ALL MODELS AVAILABLE ON SPECIFICATION.
Add E sufx denoting extra case cover for external by-pass switches, to replace standard removable cover (only available for surface type enclosure).
TW SERIES: NOTE: All models are designed to control a contactor circuit and not recommended for direct switching of most lighting loads. MANUAL BY-PASS
SWITCHES: Single pole, 20 Amps one per circuit. Factory prewired to terminal strip. ON-OFF-AUTO positions for each circuit is independent will not disturb automatic settings.




16
A DIVISION OF NSi INDUSTRIES, LLC
T900 SERIES
2 & 3 CIRCUIT
LIGHTING CONTROL
CENTERS
COMBINES PHOTOELECTRIC AND
7 DAY TIME SWITCH CONTROL
DIFFERENT SCHEDULES EACH DAY,
RESERVE POWER STANDARD

APPLICATIONS
Use for general outdoor lighting such as park-
ing lot and displays: Dusk-ON, Preset-OFF
(Photoelectric control-ON, time Switch-OFF).

Use for all night safety or security lighting:
Dusk-ON, Dawn-OFF (Photoelectric control-
ON, Photoelectric control OFF).

Use for indoor lighting or HVAC: Preset-ON,
Preset-OFF (Time Switch-ON, Time Switch-
OFF). MODEL
2101 IS
NOTE: All models are designed to SUPPLIED
control a contactor circuit and are not
WITH UNIT
recommended for direct switching of
most lighting loads.
OPTIONAL
E COVER
CONTROLS 2 OR 3 CIRCUITS:
CIRCUIT 1: ON automatically at dusk, OFF at individual preset times each day, including skipping
days when desired. Can be set to turn ON before dawn for early morning lighting.

CIRCUIT 2: ON at dusk, OFF at dawn automatically, daily.

CIRCUIT 3: Individual daily ON and OFF settings at desired times, including skipping any desired
day or days.


SPECIFICATIONS
CONTACT RATINGS: 20 Amps per Pole, 24-277 VAC (unpowered)

MANUAL BY-PASS SWITCHES: Single pole, 20 Amps one per circuit. Factory pre-wired to terminal strip.
ON-OFF-AUTO positions for each circuit independently & will not disturb automatic settings.

TIMING MOTOR: Heavy duty, self-starting synchronous motor with 24 hour spring driven reserve power standard. Power
Consumption: 5 watts.

AUTOMATIC OPERATION: Minimum ON setting: 1 Hour. Minimum OFF setting: 2 Hours. 7 day calendar dial
accommodates up to 2 pairs of ON-OFF removable trippers per day 7 pairs are supplied.

OPERATING TEMPERATURE RANGE: -40 to +165F. (-40 to +74C.)

ENCLOSURE: See page 27 for dimensions. General Purpose (NEMA 1) Steel beige enamel, lockable hasp, with combina-
tion 12 - 34 K.O.s on both sides, top and bottom. Optional E door (specify) available to replace standard removable
cover when access to external by-pass switches are required.

OTHER MOUNTINGS: *When ordering special enclosures ONLY, please use model number.
Metal Indoor/Outdoor NEMA 3: (sufx O) Model 9006*
Flush with lock & key NEMA 1: (sufx FL5) Model 9005*
Bracket Mounting specify unit without case.



18
A DIVISION OF NSi INDUSTRIES, LLC
TZ SERIES
ASTRONOMIC TIME SWITCHES
WITH MANUAL BYPASS SWITCHES
RESERVE POWER STANDARD
APPLICATIONS
Automatic control for night lighting when the ON operation
is required at sunset and it may be desirable to
override the automatic schedule ON or OFF.
Schools Industrial Yards Show Windows
Hallway Signs Parking Lots Highway Signs
Bridges
NOTE: All models are designed to control a contactor
circuit and are not recommended for direct
switching of most lighting loads.
SPECIFICATIONS
CONTACT RATINGS: (Tungsten rated at 277V) 20 Amps per circuit, 1 HP at 120V. OPTIONAL
MANUAL BY-PASS SWITCHES: Single pole, 20 Amps one per circuit. E COVER
Factory prewired to terminal strip. ON-OFF-AUTO positions for each
circuit independently will not disturb automatic settings.
TIMING MOTOR: Heavy duty, self-starting synchronous motor with 16 hour spring driven reserve power standard. Power
Consumption: 5 watts.
AUTOMATIC OPERATION: 24 hour astronomic dial, with special cams to vary the ON and OFF settings each day according to
seasonal changes of sunset and sunrise. Turns ON only at sunset can be set 20 or 40 minutes before or after normal
sunset, to adapt to local conditions. Turn OFF can be set from 8:30 P.M. to 2:30 A.M., in half-hour intervals, or at sunrise.
OMITTING DEVICE: 7-spoke wheel marked with days of week 3 omitting screws (P-14) supplied.
OPERATING TEMPERATURE RANGE: -40 to +165F. (-40 to +74C.)
ENCLOSURE: See page 27 for dimensions. General Purpose (NEMA 1) Beige enamel, lockable hasp, with combination 12
- 34 K.O.s on both sides, top and bottom. Optional E door (specify) available to replace standard removable cover
when access to external by-pass switches is required.
OTHER MOUNTINGS: *When ordering special enclosures ONLY, please use model number.
Metal Indoor/Outdoor NEMA 3: (sufx O) Model 9006*
Flush with lock & key NEMA 1: (sufx FL5) Model 9005*



CAT UPC H.P. RESERVE POWER MOTOR
NO CODE SWITCH AMPS RATING AC VOLTAGE HZ PART #

TZ-220L 29010 DPDT 20 1 120 60 36
TZ-222L 29011 DPDT 20 208-277 60 46
TZ-300L 29006 3PST 20 1 120 60 36
TZ-302L 29008 3PST 20 208-277 60 46
Add E sufx denoting extra case cover for external by-pass switches, to replace standard removable cover (only available for surface type enclosure).


WIRING DIAGRAMS
MANUAL CONTROLS MANUAL CONTROLS
NOTE:
Switching contacts
AUTO
are unpowered
TZ300L TZ220L
M
TIME
SWITCH
When single line source is M
TIME Wiring shown is for mechani-
SWITCH CONTACTOR

1 2 3 4 9
used, jumper terminals CONTROL cally-held contactors. Use
5 6 7 8 1 2 3 4 5 6 7 8 9 CIRCUIT
LINE 1-5-7-9 and connect all com- COMMON
CLOSE terminal only for mag-
H N
LOAD mons to terminals 2 and 3. H N
OPEN netically-held contactors and
LINE CLOSE
CONTACTOR
LOAD CONTROL COMMON
to control direct loads not
CIRCUIT
LINE OPEN exceeding 2000 watts.
LOAD CLOSE



SPECIFICATION WRITERS GUIDE TZ SERIES
Furnish and install where shown a TORK Time Switch with Astronomic dial and day-omitting device, and a 3-way manual switch for each circuit. The Time Switch shall be
powered by a self-starting synchronous motor with spring-driven reserve, which shall be sufcient to operate the time switch contacts at least 16 hours after power failure. On
restoration of power, time switch shall transfer to synchronous motor drive and automatically rewind reserve. ON operation shall occur automatically at sunset in (city of use).
OFF operation shall be adjustable from 8:30 P.M. to 2:30 A.M. in one-half hour increments or at sunrise. Both ON and OFF shall have a range of adjustability of 20 or 40
minutes before or after sunset and sunrise. Time Switch contacts shall be capable of carrying a minimum of 20 amperes per pole continuously at 277 volts and shall be DPST
(3PST). Manual switches shall be provided as an integral part of the time switch, one for each pole, and shall permit manual switching to maintained ON or OFF positions
until manually returned to AUTOMATIC position. Terminal strip shall be capable of receiving #10 AWG wires. Enclosure shall be NEMA 1 surface type, nished in beige
enamel, and with 1/2 - 3/4 combination knock-outs on bottom, both sides and top. Provision shall be made for positive padlocking. (Specify E door for manual switch-
es to be accessible when case is locked). Time switch shall be TORK Model TZ-___ (to t requirement).


20
A DIVISION OF NSi INDUSTRIES, LLC
Wire and Connectors
WIRE, SERVICE CORD AND SPLIT BOLTS

STRANdEd MuLTI-PuRPoSE WIRE
PVC insulated, stranded multi-purpose wire;
600V, 90C, with oil resistant nylon coating.
Supplied in convenient tangle-free grommetted
dispenser bags.

CATALOG UPC TYPE OF O.D. FT/ CTN
NO. NO. COLOR WIRE AWG STR (IN) BAG QTY
tffN16D-B 79000 black tffN 16 26 .10 48 12
tffN16D-G 79001 green tffN 16 26 .10 48 12
tffN16D-R 79002 red tffN 16 26 .10 48 12
tffN16D-W 79003 white tffN 16 26 .10 48 12
tHHN14D-B 79004 black tHHN 14 19 .11 48 12
tHHN14D-G 79005 green tHHN 14 19 .11 48 12
tHHN14D-R 79006 red tHHN 14 19 .11 48 12
tHHN14D-W 79007 white tHHN 14 19 .11 48 12
tHHN12D-B 79008 black tHHN 12 19 .13 48 10
tHHN12D-G 79009 green tHHN 12 19 .13 48 10
tHHN12D-R 79010 red tHHN 12 19 .13 48 10
tHHN12D-W 79011 white tHHN 12 19 .13 48 10
tHHN10D-B 79012 black tHHN 10 19 .17 48 8
tHHN10D-G 79013 green tHHN 10 19 .17 48 8
tHHN10D-R 79014 red tHHN 10 19 .17 48 8
tHHN10D-W 79015 white tHHN 10 19 .17 48 8
tHHN8D-B 79016 black tHHN 8 19 .22 24 8
tHHN8D-R 79017 red tHHN 8 19 .22 24 8
tHHN8D-W 79018 white tHHN 8 19 .22 24 8
ThERMoSTAT WIRE
PVC insulated and jacketed multi-conductor wire for low voltage applications. Solid copper, individually insulated & color coded.
CATALOG UPC FT/ CTN.
NO. NO. CONDUCTORS AWG BAG QTY.
tStAtD-3 79019 3 20 solid 150 12
tStAtD-5 79020 5 20 solid 40 12
tStAtD-10 79021 10 20 solid 40 12

SERVICE CoRd
PVC insulated and jacketed three-conductor cord for stranded copper conductors. Rated 300V, 60C.
CATALOG UPC FT/ CTN.
NO. NO. CONDUCTORS AWG BAG QTY.
SJtO16D-20 79026 3 16 stranded 20 10
SJtO14D-20 79027 3 14 stranded 20 10

SPLIT BoLT CoNNECToRS FoR CoPPER ANd CoPPERWELd WIRES
High-strength solderless service connector
made of high-copper alloy for copper and
copperweld wires. Type for two maximum
wire sizes.


COPPER CONDUCTOR MAxIMUM
RANGE OF EQUAL MIN. TAP CONDUCTOR WIRE DIA. RECOMMENDED SHPG.
CATALOG UPC MAIN & TAP WITH ONE COPPERWELD RANGE TORQUE CTN. WT.
NO. NO. MIN. MAx. MAx. MAIN STR TYPE A IN. (IN. LB.) QTY. LBS./100
N-10-D 78989 16 str.10 str. 16 str. .057 -.116 80 3 1.8
N-8-D 78990 16 str. 8 str. 16 str. .057 - .145 80 3 2.8
N-6-D 78991 10 sol. 6 sol. 16 sol. .102 - .162 165 3 5.5
N-4-D 78996 8 sol. 4 sol. 16 sol. 3 N 12 8A .128 - .204 165 3 7.7
N-1/0-D 78997 4 sol.1/0 str. 14 sol. 3 N 6 2A .204 - .375 385 3 16
N-2/0-D 78998

June 2008 www.nsiindustries.com Nsi 11
Identification Products
POCKET-PAL BOOKS


POCKET-PAL BOOKS
Convenient NSi wire marker books made with vinyl impregnated cloth. A strong adhesive ensures the
marking will last. Printed with black legends on a white background. Each book
contains 450 wire markers. Temperature range:
-40F to 250F.




Catalog UPC MarkErS CartoN
No. CoDE lEgEND PEr book qty.

WMB-1 09000 0-9 45 each 12
WMB-2 09001 A-Z, 0-15 +, -, / 10 each 12
WMB-3 09002 1-45 10 each 12
WMB-4 09003 1,2,3 150 each 12
WMB-5 09004 A,B,C 150 each 12
WMB-6 09005 T1,T2,T3 150 each 12
WMB-7 09006 L1,L2,L3 150 each
WMB-8 09007 1-15 6 each 12
16-90 4 each
A-Z, +, - , /, 0 2 each
WMB-9 09008 1,2,3 45 each 12
A,B,C 45 each
L1,L2,L3 30 each
T1,T2,T3 30 each
WMB-10 09009 10 NEMA COLORS 45 each 12
WMB-11 09010 1-30 15 each 12
WMB-12 09011 A-Z 15 each 12
BLANK 21 each
+ 8 each
- 7 each
WMB-13 09012 +, -, AC, DC 45 each 12
POS, NEG, GND 33 each
NEUT 27 each
SPARE, BLANK 21 each
WMB-14 09013 0-9 45 each 12
L1,L2,L3 15 each
T1,T2,T3 15 each
WMB-15 09014 46-90 10 each 12
WMB-16 09015 1-33,A,B,C,+,-
L1,L2,L3,T1,T2,T3 10 each
WMB-20 09016 1 X 6 BLANK 30 each 12
(1 X 1 WRITE-ON AREA)
WMB-21 09017 1 X 3 BLANK 60 each 12
(1 X 1 WRITE-ON AREA)
WMB-LC 12110 load center legends 450 each 12
WMB-T 12111 datacom/telecom legends 450 each 12

Note: WMB-21 is clear laminating vinyl with white marking tab.




42 NSi Phone: 800.321.5847 Fax: 800.841.5566
HPS STARTER
FOR HIGH PRESSURE SODIUM LAMPS


Designed to operate as a starting aid to all H.P.S. ballasts from 35 to 400 watts and with lamp voltages of 55 or 100 volts.
FEATURES
Delivers appropriate trigger spikes for lamp ignition, then reduces voltage to good lamps.
Continues to feed voltage spikes to old or poorly working lamps.
All components are sealed with high grade die-electric material to protect against contaminants and other adverse environ-
mental conditions.
Durable, high temperature Lexan housing.
Universal 3 wire design, color coded for ease of installation. SPECIFICATIONS
LINE VOLTAGE: 105-347VAC
WIRING DIAGRAM LAMP VOLTAGE: 55 or 100VA
LAMP WATTAGE: 35 to 400 watts
BALLAST OPERATING TEMP. -40 to 221F (-40 to 105C)
BLACK
CENTER LEAD LENGTH: 9 inches
H.P.S. CONTACT
RED
TAP STARTER
LAMP CATALOG UPC
WHITE
SHELL NO CODE DESCRIPTION

LINE COMMON HPS30 81030 HIGH PRESSURE SODIUM STARTER



TRP SERIES
TRANSFORMER
RELAY POWER PACKS
Self contained transformer and relay with SPST contacts rated at 20 Amp 120VAC or 277VAC. Internal power source provides for
low voltage control of line voltage contacts, eliminating the need for a separate step down transformer.
APPLICATIONS SPECIFICATIONS
Low voltage switching of line voltage lighting circuits up CONTACTS: SPST Contacts
to 20 Amp ballasts or 15 amp tungsten loads. Also up to CONTACT RATING: 20 Amps Ballast @ 120 or 277VAC
1.0 HP motors for ventilating and exhaust fans. 15 Amps Tungsten @ 120VAC
For simple installation of low voltage wiring between 3-way 1.0 Horsepower @ 120VAC
switches. TEMPERATURE RANGE: 0 to 150F (18 to 66C)
Low voltage switching by digital or mechanical controls for SIZE (SINGLE TRP): 234 x 112 x 158
higher amperage loads including those of two different can be mounted in standard junction
voltages. box or recess lighting fixture.
For multi-channel digital controls, TORK offers TRPs which are avail- WEIGHT: 7 oz.
able in groups of 4 or 8, conveniently prewired in metal enclosure.
Panels are not UL listed.
ENCLOSURE DIMENSIONS
CATALOG UPC INPUT TRP 400 (GROUP OF 4) TRP 800 (GROUP OF 8)

NO CODE DESCRIPTION VOLTAGE 9/32"
MOUNTING HOLES 9/32"
MOUNTING HOLES

TRP-1 82032 SINGLE TRANSFORMER RELAY POWERPACK 120VAC
TRP-2 82033 SINGLE TRANSFORMER RELAY POWERPACK 277VAC
12"

*TRP400 82132 FOUR TRANSFORMER RELAY POWERPACKS 120VAC 18"


*TRP402 82133 FOUR TRANSFORMER RELAY POWERPACKS 277VAC 4" 10"


*TRP800 82135 EIGHT TRANSFORMER RELAY POWERPACKS 120VAC
12" 4"
*TRP802 82136 EIGHT TRANSFORMER RELAY POWERPACKS 277VAC
*NOT FOR USE WITH OCCUPANCY SENSORS


SURGE SUPPRESSOR
FOR HIGH ELECTRICAL
CATALOG UPC
NOISE INTERFERENCE,
NO CODE DESCRIPTION
RECOMMENDED FOR
ALL DIGITAL CONTROLS 90058-1 81024 SURGE SUPPRESSOR


38 A DIVISION OF NSi INDUSTRIES, LLC
ALPHANUMERIC INDEX TERMS OF SALE
CATALOG TORK VENDOR NUMBER: 786261
NUMBER PAGE
1. Prices are F.O.B. our plant.
451D . . . . . . . . . . . . . . . . . . . . . 36 2. Prices do not include any sales tax.
631D . . . . . . . . . . . . . . . . . . . . . 36 3. Freight charges will be prepaid on all orders $250.00 and over
653A, 654A . . . . . . . . . . . . . . . . 36 shipping within continental USA using standard shipping meth-
5401, 5440, 5441 . . . . . . . . . . . 37 ods and service.
90058-1 . . . . . . . . . . . . . . . . . . 38 4. Minimum order $100.00.
5. Claims for shortage, erroneous charges or price corrections shall
ACT . . . . . . . . . . . . . . . . . . . 30,31
be deemed waived unless made in writing, delivered to NSi
DG, DGM . . . . . . . . . . . . . . . 10,11
within 30 days of invoice.
DGLC . . . . . . . . . . . . . . . . . . 14,15
6. Terms of payment 2% 10th prox. net 25th following.
DGU, DGUM . . . . . . . . . . . . . 12,13
7. Warranties NSi guarantees all products to be free of defects in
DGS . . . . . . . . . . . . . . . . . . . . . . 9
material and workmanship for a period of 1 year from date of
DIN . . . . . . . . . . . . . . . . . . . . . . . 3
sale. Any claims for defective material must be agreed to in
DLC400BP . . . . . . . . . . . . . . . 22,23 writing by NSi. Defective material will be replaced on an F.O.B.
DTS . . . . . . . . . . . . . . . . . . . . 18,19 our factory basis. NSi disclaims the implied warranty of tness
DW, DWZ . . . . . . . . . . . . . . . 20,21 for a particular application.
DZS . . . . . . . . . . . . . . . . . . . 16,17
DZM . . . . . . . . . . . . . . . . . . . . . 24
E101B, E103B, E120B . . . . . . . . 4,5 OTHER PRODUCTS AVAILABLE
E101PB, E103PB, E120PB . . . . . . . 6
EH . . . . . . . . . . . . . . . . . . . . . . . . 8 NSi can provide many other products for special applications which
EW . . . . . . . . . . . . . . . . . . . . . .4,5 are not listed in this catalog. If you require an item which you do
EWZ . . . . . . . . . . . . . . . . . . . . . . 7 not nd listed, please contact us. We would be pleased to provide a
HPS . . . . . . . . . . . . . . . . . . . . . . 38 quotation upon receipt of a drawing or a sample.
K . . . . . . . . . . . . . . . . . . . . . . . . 25
LC . . . . . . . . . . . . . . . . . . . . . . . 28
MMP . . . . . . . . . . . . . . .16, 23, 24 GUARANTEE
SMC . . . . . . . . . . . . . . . . . . 29
SS . . . . . . . . . . . . . . . . . . 34 It is our goal to provide extraordinary products and service on a
SS700Z . . . . . . . . . . . . . 35 daily basis. If our products or service do not meet with your satis-
SS720A . . . . . . . . . . . . 35 faction, please let us know immediately and we promise to make
SSA . . . . . . . . . . . . 32,33 every reasonable effort to remedy the situation.
TRP . . . . . . . . . . . . . . . 38




41
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC




Powered by Venture