INDOOR/OUTDOOR NEMA III METAL CASE

NSI / Tork Electrical, Lighting Pool & Spa Products and Replacement Parts

1100 SERIES
24 HOUR
TIME SWITCHES
SAME ON/OFF TIMES
EACH DAY

APPLICATIONS
Automatic ON-OFF control when operation is
required at thesame time every day, 7 days a
week.
Lighting
Pumps 1101
Signs
Air Conditioning
Water Heating
Fans


SPECIFICATIONS
CONTACT RATINGS:
(all models except 1101-7):
40 Amp. Tungsten, 120VAC
40 Amp. Resistive, 120-277VAC
Single Phase
40 Amp. General Purpose
120-277 VAC Single Phase
20 Amp. Inductive 120VAC, 277VAC,
Single Phase
1000 VA Pilot Duty 120-277 VAC.
2 HP (24 FLA) 120 VAC; 5 HP (28 FLA) 240 VAC
Model 1101-7 is 30 amp inductive, 347 VAC only
1101 NC
TIMING MOTOR: Heavy duty synchronous, self-starting WITH CLEAR
high torque. Power Consumption: 3 watts. LEXAN COVER
AUTOMATIC OPERATION: Minimum ON setting: 20 minutes.
Minimum OFF setting: 75 minutes. One pair of ON-OFF
trippers supplied accommodates up to 12 pairs.
Dial markings are in English, French and Spanish.

TEMPORARY MANUAL OVERRIDE: Standard.

OPERATING TEMPERATURE RANGE: 40 to +165F.(40 to +74C.)

ENCLOSURE: See page 27 for dimensions. Metal Indoor (NEMA 1). Drawn steel, beige enamel, with combination 12 and
3
4 K.O.s on sides, bottom and back. Lockable hasp. Cover is removable and movement releases from case at nger
touch for easy installation. Back has keyhole as well as matching screw holes for quick mounting over single gang box.

OTHER MOUNTINGS: *When ordering special enclosures ONLY, please use model number.
Noryl Indoor/Outdoor NEMA 3R: Models with sufx N. Enclosure only: Model 9000N*
Noryl Indoor/Outdoor NEMA 3R with clear cover: Models with sufx NC. Enclosure only: Model 9000NC*
Metal Indoor/Outdoor NEMA 3: Models with sufx O. Enclosure only: Model 9000A*
Metal Flush, with lock and key: (sufx FL 1). Enclosure only: Model 9001*
Metal Duplex 2 standard units in one indoor/outdoor case: (sufx DUOL). Enclosure only: Model 9004L*
Bracket mounting specify mechanism only with bracket
Intermatic Adapter Plate Model IAPallows any TORK 1100 model
to t into an Intermatic case without changing enclosure.




2
A DIVISION OF NSi INDUSTRIES, LLC
7000 SERIES
24 HOUR
TIME SWITCHES
WITH SKIP-A-DAY FEATURE
RESERVE POWER OPTIONAL



APPLICATIONS
Automatic ON-OFF control when operation is required at the same time every
day, with optional versatility of one to six days omission.
Lighting Heating Pumps
Air Conditioning Signs

SPECIFICATIONS
CONTACT RATINGS:
40 Amp. Tungsten, 120 VAC
40 Amp. Resistive, 120-277 VAC Single Phase
40 Amp. General Purpose, 120-277 VAC Single Phase
20 Amp. Inductive 120 VAC, 277 VAC Single Phase
1000 VA Pilot Duty 120-277 VAC.
2 HP (24 FLA) 120 VAC; 5 HP (28 FLA) 240 VAC

TIMING MOTOR: Heavy duty synchronous self-starting high torque. Power Consumption: 3 watts.

OPTIONAL RESERVE POWER: Keeps dial on time up to 16 hours during power outage.
Add sufx L to model number. Power Consumption: 5 watts.

AUTOMATIC OPERATION: Minimum ON setting: 20 minutes. Minimum OFF
setting: 75 minutes. One pair of ON-OFF trippers supplied accommodates
up to 12 pairs. Dial markings are in English, French and Spanish.

OMITTING DEVICE: 7-spoke wheel marked with days of week 3 omitting screws (P-14) supplied.

TEMPORARY MANUAL OVERRIDE: Standard.

OPERATING TEMPERATURE RANGE: -40 to +165F. (-40 to +74C.)

ENCLOSURE: See page 27 for dimensions. General purpose (NEMA 1). Drawn steel, beige enamel, with combination 12
and 34 K.O.s on sides, bottom and back. Lockable hasp. Removable cover provides exceptional accessibility for wiring
and setting. Mechanism releases from case at nger touch for easy installation, (except 3 Pole Models which include
metal indoor/outdoor case as standard).

OTHER MOUNTINGS: *When ordering special enclosures ONLY, please use model number.
Noryl Indoor/Outdoor NEMA 3R: (sufx N) Model 9000N*
Metal Indoor/Outdoor NEMA 3: (sufx O) Model 9000A*
Flush, with lock and key: (sufx FL1) Model 9001*
Flush, with lock and key, NEMA 1B for 3 pole: (sufx FL2) Model 9002*
Duplex 2 standard units in one indoor/outdoor NEMA 3 metal
case except 3 pole: (sufx DUOL) Model 9004L*
Bracket mounting specify mechanism only with bracket.
Intermatic Adapter Plate Model IAP allows any TORK 7000 model
to t into an Intermatic case without changing enclosure




4
A DIVISION OF NSi INDUSTRIES, LLC
1100 SERIES
SWIMMING POOL TIME SWITCHES
1 AND 2 CIRCUIT, 24 HOUR DIAL
APPLICATIONS
Automatic ON-OFF control of swimming pool pumping systems with
or without water heaters. Two units in one case allow for addition of
lighting control, or automatic pool sweep ON. Models with FM
sufx contain low voltage secondary circuit to turn OFF water heater
thermostat 20-30 minutes before standard voltage main circuit turns
OFF pump. This allows for slow cooling of heater coils, preventing
sudden steam build-up and knocking, thereby prolonging heater life.
SPECIFICATIONS
CONTACT RATINGS:
40 Amp. Tungsten, 120 VAC
40 Amp. Resistive, 120-277 VAC Single Phase
40 Amp. General Purpose, 120-277 VAC
Single Phase
20 Amp. Inductive 120 VAC, 277 VAC Single Phase
1000 VA Pilot Duty, 120-277 VAC.
2 HP (24 FLA) 120 VAC; 5 HP (28 FLA) 240VAC

WATER HEATER CIRCUIT: 760VA, 24V

TIMING MOTOR: Heavy duty synchronous, self-start-
ing high torque. Power Consumption: 3 watts

AUTOMATIC OPERATION: Models with FM sufx
Include one pair of permanent type ON-OFF trip-
pers. Can accommodate up to 3 pairs. Minimum
ON setting, 45 minutes. Minimum OFF setting, 90
minutes. All other models include 1 pair of ON-OFF
trippers can accommodate up to 12 pairs.
Minimum ON setting, 20 minutes. Minimum OFF CAT UPC H.P. MOTOR:
setting, 75 minutes. Dial markings in English, NO CODE ENCLOSURE TYPE SWITCH RATING AC VOLTAGE
French & Spanish. 1101 10011 Metal Indoor SPST 2 120
1103 10013 Metal Indoor DPST 2 120
TEMPORARY MANUAL OVERRIDE: Standard. 1104 10014 Metal Indoor DPST 5 208-277
1101 FM 10018 Metal Indoor SPST 2 120
OPERATING TEMPERATURE RANGE: -40 to +165F. (- 1104 FM 10020 Metal Indoor DPST 5 208-277
40 to +74C.) 1101 FM N 10043 Noryl Indoor/Outdoor SPST 2 120
1104 FM N 10044 Noryl Indoor/Outdoor DPST 5 208-277
ENCLOSURE: See page 27 for dimensions. Metal
Indoor (NEMA 1). Drawn steel, beige enamel, 1101-O 10015 Metal Outdoor SPST 2 120
with combination 12and 34 K.O.s on sides, bot- 1103-O 10016 Metal Outdoor DPST 2 120
tom and back. Lockable hasp. Cover is remove- 1104-O 10017 Metal Outdoor DPST 5 208-277
able and movement releases from case at nger 1101 FM-O 10019 Metal Outdoor SPST 2 120
touch for easy installation. Back has keyhole as 1104 FM-O 10021 Metal Outdoor DPST 5 208-277
well as matching screw holes for easy mounting 1101 M 10022 Mechanism Only SPST 2 120
over single gang box. 1103 M 10023 Mechanism Only DPST 2 120
1104 M 10024 Mechanism Only DPST 5 208-277
OTHER MOUNTINGS: *When ordering special enclo- 1101 FM M 10025 Mechanism Only SPST 2 120
sures ONLY, please use model number. 1104 FM M 10026 Mechanism Only DPST 5 208-277
Noryl Indoor/Outdoor NEMA 3R: (sufx N) Contains
Model 9000N* 1101 D 10028 Two units in metal indoor /outdoor 2 each 1101
Metal Indoor/Outdoor NEMA 3: (sufx O) 1114 D 10030 Two units in metal indoor /outdoor 1 each 1101, 1 each 1104
Model 9000A* (hinged side) 1104 D 10029 Two units in metal indoor /outdoor 2 each 1104
Duplex: 2 units in one indoor/outdoor NEMA 3 1101 DF 10027 Two units in metal indoor /outdoo 1 each 1101, 1 each 1101 FM
metal case (sufx DUOL) Model 9004L* 1114 DF 10030 Two units in metal indoor /outdoor 1 each 1101, 1 each 1104 FM
Bracket mounting specify mechanism only 1104 DF 10032 Two units in metal indoor /outdoor 1 each 1104, 1 each 1104 FM
with bracket. FM MODELS CONTAIN LOW VOLTAGE POOL HEATER THERMOSTAT SWITCH
Intermatic Adapter Plate Model IAP allows any Reserve Power is not available in this series.
TORK 1100 model to t into an Intermatic
case without changing enclosure

6
A DIVISION OF NSi INDUSTRIES, LLC
1800 SERIES
MOMENTARY CONTACT
TIME SWITCHES
FOR MECHANICALLY-HELD CONTACTORS
AND LOW VOLTAGE REMOTE CONTROL
RESERVE POWER OPTIONAL
APPLICATIONS
Mechanically-held contactors
3 wire momentary lighting systems
Remote station switching
SPECIFICATIONS
CONTACTS: 2 normally open dry contacts. 10 Amp @
24-277 VAC, 360 VA
TIMING MOTOR: Heavy duty synchronous, self-starting
high torque. Power Consumption: 3 watts.

OPTIONAL RESERVE POWER: Keeps dial on time up to 16
hours (on 24 hour models); up to 24 hours (on 7 day models)
during power outage. Add sufx L to model number.
Power Consumption: 5 watts.

MOMENTARY TIMING CIRCUIT: Solid state circuit drives two
high capacity dry contacts to either ON or OFF contactor
coil terminals. Dry contacts close for a period of 5 seconds
and occur at such times as are set on the time switch dial.

DIAL: Choice of 24 hour, Astronomic or 7-day calendar dials
all can omit selected days, if desired.

OPERATING TEMPERATURE RANGE: -40 to +165F.
(-40 to +74C.)

ENCLOSURE: See page 27 for dimensions. General purpose CAT UPC MOTOR: MOTOR:
(NEMA 1). Drawn steel, beige enamel, with combination 12-34 NO CODE TYPE AC VOLTAGE Hz
K.O.s on top, sides, bottom and back. Lockable hasp.
1847A 52001 24 Hour 120 60
OTHER MOUNTINGS: *When ordering special enclosures ONLY, 1848A 52014 24 Hour 208-277 60
please use model number. 1847AZ 52003 Astronomic 120 60
Noryl Indoor/Outdoor NEMA 3R: 1848AZ 52018 Astronomic 208-277 60
(sufx N) Model 9000N* 1847AW 52005 7 Day 120 60
Metal Indoor/Outdoor NEMA 3:
(sufx O) Model 9000A* 1848AW 52016 7 Day 208-277 60
Flush, with lock and key NEMA 1:
(sufx FL1) Model 9001* WITH RESERVE POWER
1847AL 52006 24 Hour 120 60
WIRING DIAGRAM 1848AL 52015 24 Hour 208-277 60
OFF C ON TIMING MOTOR 1847AZL 52008 Astronomic 120 60
MECHANICALLY-HELD
CONTACTOR
1848AZL 52019 Astronomic 208-277 60
L 120VAC, 60HZ
CLOSE
1847AWL 52010 7 Day 120 60
N COMMON 1848AWL 52017 7 Day 208-277 60
OPEN
ON
NOTE: Timing motor voltage need not be the same as contactor coil voltage

OFF
MOMENTARY PUSH BUTTON


SPECIFICATION WRITERS GUIDE
1800 SERIES
Furnish and install where shown a Momentary Contact Time Switch. Time Switch shall have dial of the (24 hour with day omitting device) (Astronomic with day omitting device)
(7 day calendar) type, which shall be suitable to operate mechanically-held contactor of maximum size. Terminal board shall enable fast and correct installation using screw
terminals for up to AWG #12 wire. Timing motor terminals are completely independent from momentary switching circuit. Spring driven reserve mechanism shall be provided
sufcient to operate time switch controls at least 16 hours after power failure. On restoration of power, time switch shall transfer to synchronous motor drive and automatical-
ly rewind reserve. Time Switch shall include solid state circuit to provide a switch closure not in excess of two seconds on both ON and OFF contactor coil terminals at such
times as are set on dial: these settings to be made with removable trippers which can be added and removed without tools (except the astronomic dial). Contactor coil circuits
shall be suitable for 10 Amp @ 24-277 VAC, 360 VA. Enclosures shall be NEMA 1 surface (or see other mountings), with provision for padlocking. Time Switch shall be
TORK Model 1847AL, (1848AL), (1849AL), (AZL), (AWL).



10
A DIVISION OF NSi INDUSTRIES, LLC
8000 SERIES
DUTY CYCLE 24 HOUR TIME
SWITCHES
MANY ON/OFF OPERATIONS PER DAY
APPLICATIONS
For one to many daily ON-OFF operations
Duty Cycling Pumping Process Control
Ventilating Fans Irrigation Laboratory
Experiments
SPECIFICATIONS
CONTACT RATINGS: 20 Amps at 120 or 240V, 5 Amps at 480V,
3
4 HP @120V AC
TIMING MOTOR: Heavy duty synchronous, self-starting, high torque.
Power Consumption: 3 watts.
OPTIONAL RESERVE POWER: Keeps dial on time up to 16 hours during power
outage. Add sufx L to model number. Power Consumption: 5 watts.
DIAL: Captivated tabs for setting are easily tilted in or out by hand.
Switch stays ON or OFF as set when adjacent tabs are set alike.
1 TO 48 ON-OFF OPERATIONS PER DAY.
96 tabs permit 15 minute switching changes.
DUTY CYCLES adjustable from 12, 1, 2, 3, 4, 6, 12 and 24 hours.

OPERATING TEMPERATURE RANGE: -40 to +165F. (-40 to +74C.)

ENCLOSURE: See page 27 for dimensions. General purpose (NEMA 1). Drawn steel, beige enamel, with combination 12and
3
4 K.O.s on sides, bottom and back. Lockable hasp. Cover is removable and movement releases from case at nger touch
for easy installation.
WIRING DIAGRAM
OTHER MOUNTINGS: *When ordering special enclosures ONLY, please use model number. ALL SPDT M
Noryl Indoor/Outdoor NEMA 3R: (sufx N) Model 9000N* MODELS

Metal Indoor/Outdoor NEMA 3: (sufx O) Model 9000A*
Flush, with lock and key: (sufx FL1) Model 9001*
Duplex 2 standard units in one indoor/outdoor NEMA 3 metal L
C NC NO
2

case: (sufx DUOL) Model 9004L* H LOAD 2

Bracket mounting specify mechanism only with bracket. 120VAC
CLOSED WITH
TAB OUTWARD

Intermatic Adapter Plate Model IAP allows any TORK 8000 model to N LOAD 1

t into an Intermatic case without changing enclosure CLOSED WITH
TAB INWARD




CAT UPC H.P. MOTOR: MOTOR:
NO CODE SWITCH TYPE AMPS RATING AC VOLTAGE Hz

8001 70001 SPDT 24 Hour 20 3
4 120 60
8004 70002 SPDT 24 Hour 20 3
4 208-277 60
8001U 70003 SPDT 24 Hour 5 3
4 480/120 Trans. 60
8007 70005 SPDT 24 Hour, 7 Day Omit 20 3
4 120 60
8008 70006 SPDT 24 Hour, 7 Day Omit 20 3
4 208-277 60
8007V 70007 SPDT 24 Hour, 14 Day Omit 20 3
4 120 60
WITH RESERVE POWER
8007L 70015 SPDT 24 Hour, 7 Day Omit 20 3/4 120 60
8008L 70016 SPDT 24 Hour, 7 Day Omit 20 3/4 208-277 60
8007VL 70017 SPDT 24 Hour, 14 Day Omit 20 3/4 120 60
24 VOLT IN ALL MODELS AVAILABLE ON SPECIFICATION.



SPECIFICATION WRITERS GUIDE 8000 SERIES
The time switches shall be of duty cycle type, capable of programming at 15-minute intervals of the day. Schedule tabs shall be captive on the dial, and shall be easily set
by hand without tools to obtain or to change the desired schedule. The switching condition shall be maintained when adjacent tabs are set alike. The unit shall be powered
by a self-starting enclosed 120 (or 208-277) volt synchronous motor capable of continuous accurate operation. The switch mechanism shall be a self-contained unit rated at
not less than 20 amps, 120 volts, single pole, double throw, and shall be readily replaceable in the eld.
FOR 8001 ADD: The time switch shall be similar and equal to Tork Model 8001. FOR 8007 AND 8007V ADD: An omitting device shall be furnished as an integral part of
the time switch, to enable the switching operation to be skipped for any preselected day or days of the week. The time switch shall be similar and equal to Tork Model 8007
or (8007V.) FOR 8007L ADD: (Same description as for 8007). The unit shall incorporate an integral electrically wound spring reserve power unit, which shall power the
clock mechanism for up to 16 hours on a power failure. The time switch shall be similar and equal to Tork Model 8007L. FOR 8001U: The unit shall be furnished with built-
in 480-120V transformer to operate timing motor in parallel with 480 volt load. The time switch shall be Tork Model 8001U.


11
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
8000 SERIES
REPEATING VARIABLE CYCLE
TIME SWITCHES
MULTIPLE ON/OFF CYCLES PER DAY
APPLICATIONS
For one to many daily ON-OFF operations
Duty Cycling Pumping Process Control
Ventilating Fans Irrigation Laboratory
Experiments
SPECIFICATIONS
CONTACT RATINGS: 20 Amps at 120 or 240V, 5 Amps at 480V, 3/4 HP at
120V AC
TIMING MOTOR: Heavy duty synchronous, self-starting, high torque. Power
Consumption: 3 watts.
DIAL: Captivated tabs for setting are easily tilted in or out by hand. Switch stays
ON or OFF as set when adjacent tabs are set alike.

60 MINUTE DUTY CYCLE DIAL
1 to 30 ON-OFF operations per hour, 60 tabs permit 1 minute switching
changes. Total Duty Cycle adjustable from 2, 3, 4, 5, 6, 10, 12, 15, 20, 30,
or 60 minutes with 1 minute minimum ON and/or OFF settings.

30 MINUTE, 12 MINUTE, AND 6 MINUTE DIALS
60 tabs available with minimum ON or OFF settings of 1/60th of dial speed.

OPERATING TEMPERATURE RANGE: -40 to +165F. (-40 to +74C.)

ENCLOSURE: See page 27 for dimensions. General purpose (NEMA 1). Drawn steel, beige enamel, with combination 12and
3
4 K.O.s on sides, bottom and back. Lockable hasp. Cover is removable and movement releases from case at nger
touch for easy installation.
WIRING DIAGRAM
OTHER MOUNTINGS: *When ordering special enclosures ONLY, please use model number. M
ALL SPDT
Noryl Indoor/Outdoor NEMA 3R: (sufx N) Model 9000N* MODELS

Metal Indoor/Outdoor NEMA 3: (sufx O) Model 9000A*
Flush, with lock and key: (sufx FL1) Model 9001*
Duplex 2 standard units in one indoor/outdoor NEMA 3 metal case: L
C NC NO
2

(sufx DUOL) Model 9004L* H LOAD 2

Bracket mounting specify mechanism only with bracket. 120VAC
CLOSED WITH
TAB OUTWARD

Intermatic Adapter Plate Model IAP allows any TORK 8000 model to N LOAD 1

t into an Intermatic case without changing enclosure CLOSED WITH
TAB INWARD




CAT UPC H.P. MOTOR: MOTOR:
NO CODE SWITCH TYPE AMPS RATING AC VOLTAGE Hz

8601 70034 SPDT 60 Minute 20 4
3
120 60
8602 70035 SPDT 60 Minute 20 112 208-277 60
8301 70033 SPDT 30 Minute 20 3
4 120 60
8121 70032 SPDT 12 Minute 20 3
4 120 60
8061 70031 SPDT 6 Minute 20 3
4 120 60
24 VOLT IN ALL MODELS AVAILABLE ON SPECIFICATION.




SPECIFICATION WRITERS GUIDE 8000 SERIES
The repeating variable cycle time switch shall be of the program tab-type, capable of program-ming in increments of 1/60 of one dial rotation. Program tabs shall be cap-
tive on dial and shall be easily set by hand without tools to obtain or change the desired programming schedule. The switching condition shall be maintained when adjacent tabs
are set alike. The unit shall be powered with a self-starting, enclosed 120 (or 208-277) volt, synchronous motor capable of continuous accurate operation. The switch mech-
anism shall be a self-contained unit rated at not less than 20 amperes, 240 volt AC, SPDT, and shall be readily replaceable in the eld. OPTION 1: Unit shall be furnished less
case with mounting bracket (for mounting in control panel). OPTION 2: Enclosure shall be NEMA 1 surface with combination 1/2" and 3/4" knockouts on bottom, both sides,
top and back (or see other mountings). There shall be at least 25 cubic inches of available space at bottom of enclosure to facilitate wiring. A slip-out arrangement
will be included to permit prompt removal of the time switch mechanism. Provision shall be made for positive padlocking. Timer shall complete one dial rotation in
_____ minute(s) and shall be TORK Model 8 _ _ _ (to t requirement).



12
A DIVISION OF NSi INDUSTRIES, LLC
ENCLOSURE & MECHANISM DIMENSIONS
METAL INDOOR NEMA 1 METAL INDOOR/OUTDOOR 5-1/4"

#68229 NEMA 3
STD. FOR
MODELS
4-11/16" Model 9000A Suffix O 8-1/4"
1101 7200 8121
1102 7202 8301 STD. FOR MODELS
1103 7120 8601 7-15/16"
7300, (L) 7302Z
1104 7122 8602 7302, (L) 7300ZL 4-5/8"


1101FM 8001 TORK 7300Z 7302ZL
1104FM 8004
AVAILABLE FOR MODELS
7100 8061
2-15/16" 1101 7200, (L,Z,ZL) 1847AL 8007V
7102 1102 7202, (L,Z,ZL) 1847AZL 8061
1103 7120, (L,Z,ZL) 8001 8121
1104 7122, (L,ZL) 8004 8301
1101FM 7220, (L) 8001U 8601
1104FM 7222, (L) 8007 8602
METAL INDOOR NEMA 1 7100 1847A 8007L
#63100 7102 1847AZ
5"
STD. FOR MODELS
7220, (L) 1847AL
7222, (L) 1847AZL
7200L 8007 9-1/4"
7202L 8007L
METAL INDOOR/OUTDOOR
7120L 8007V
NEMA 3 8-3/8 "


1847A 8150
TORK
Model 9006 Suffix O
1848A 8150U AVAILABLE FOR MODELS
1849A W100 W220 TW220L 13-1/8"

3-3/4" W200 W222 TW300L
1847AZ
W202 W220L T920L
W300 W222L T930L
W302 W300L 1847AW
W120 W302L 1847AWL 5-3/16 "

METAL INDOOR NEMA 1
#63016-1 8-1/8"


STD. FOR MODELS
TZ220L W302L
5"
12-1/8 "
TZ300L TW220L NORYL INDOOR/OUTDOOR


W300 TW300L
TORK NEMA 3R
W302 T920L
W300L T930L
Model 9000N Suffix N 9-1/8"


STD. FOR MODELS
4-3/4"
7200Z,(L, ZL) TORK


7202Z,(L, ZL)
7120Z,(L, ZL)
4-1/2"
7122Z, (L, ZL)
METAL INDOOR NEMA 1 AVAILABLE FOR MODELS
#70100 7-5/8 " 1101 7102 7222, (L) 8001U
1102 7200, (L) 1847A 8061
STD. FOR MODELS 1103 7202, (L) 1847AZ 8121
W100 W222 1104 7120, (L) 1847AL 8301
1101FM 7122, (L) 1847AZL 8601
W200 W220L
11-7/8 "
1104FM 7220, (L) 8001 8602
W202 W222L 7100 8004
W120 1847AW TORK



W220 1847AWL

3-1/4 "




METAL INDOOR NEMA 1 NORYL & LEXAN 5"

for W400 Series NEMA 3R
12 -1/2" INDOOR/OUTDOOR TORK 9-1/8"
STD. FOR MODELS Model 9000NC
W400A W400AL
STD. FOR MODELS
W402A W402AL 1101NC
4" 1103NC
4-1/2"
8 -1/4" 1104NC




26
A DIVISION OF NSi INDUSTRIES, LLC
ENCLOSURE DIMENSIONS
METAL INDOOR NEMA 1 METAL FLUSH NEMA 1
#68229 Model 9011 Suffix FLG
4-11/16"
8"
AVAILABLE FOR MODELS
STANDARD FOR MODELS DG Series (except DGU,
EH10B, EH20B 7-15/16" DGUM, DGLC)
DZS Series 11" 9-1/8"

TORK
DTS Series
DW Series
DWZ Series
6-1/8"
2-15/16" E Series 4-3/16"




METAL INDOOR/OUTDOOR 5-1/4"


NEMA 3
Model 9000A Suffix O 8-1/4"

METAL INDOOR 5"
NEMA 1 AVAILABLE FOR MODELS
#63100 DW, DWZ, DZS, DTS Series 4-5/8"

E100B Series
STANDARD FOR MODELS 9-1/4" E100PB Series
EW100B
LC200 EWZ Series
LDS-A TORK DG Series
LDSH-A (except DGU,
DGUM, DGLC)
AVAILABLE FOR MODELS
3-3/4"
DW, DWZ, DZS, DTS Series 5"

DG Series NORYL INDOOR/OUTDOOR
NEMA 3R
Model 9000N Suffix N 9-1/8"



STANDARD FOR MODELS
TORK
DG Series DWZ Series
DZS Series SMC-3D
PLASTIC INDOOR PLASTIC INDOOR DTS Series 4-1/2"

NEMA 1 NEMA 1 DW Series
Model 1000P WITH CLEAR WINDOW
Model 1000PC
STANDARD FOR E100PB SERIES AVAILABLE FOR E100PB SERIES
NORYL INDOOR/OUTDOOR
NEMA 3R
5-1/16"
5-1/16"
WITH LEXAN CLEAR WINDOW
Model 9000NC 5"


AVAILABLE FOR MODELS
8-5/16"
8-5/16" DW, DWZ, DZS, DTS Series TORK 9-1/8"
DG Series


3-1/16"
3-1/16" 4-1/2"




5-1/16"
PLASTIC 5-1/16"
PLASTIC
INDOOR/OUTDOOR INDOOR/OUTDOOR
NEMA 3R NEMA 3R
Model 9000P 8-5/16"
WITH CLEAR WINDOW 8-5/16"



Model 9000PC
STANDARD FOR SERIES: AVAILABLE FOR SERIES:
E100B 3-1/16"
E100B
EW100B EW100B 3-1/16"

EWZ101/201/120 EWZ101/201/120




40 A DIVISION OF NSi INDUSTRIES, LLC




Powered by Venture
Open Source ERP Software