120V SPDT 20A 24 HOUR DUTY CYCLE WITH SKIP-A-DAY

NSI / Tork Electrical, Lighting Pool & Spa Products and Replacement Parts

8000 SERIES
DUTY CYCLE 24 HOUR TIME
SWITCHES
MANY ON/OFF OPERATIONS PER DAY
APPLICATIONS
For one to many daily ON-OFF operations
Duty Cycling Pumping Process Control
Ventilating Fans Irrigation Laboratory
Experiments
SPECIFICATIONS
CONTACT RATINGS: 20 Amps at 120 or 240V, 5 Amps at 480V,
3
4 HP @120V AC
TIMING MOTOR: Heavy duty synchronous, self-starting, high torque.
Power Consumption: 3 watts.
OPTIONAL RESERVE POWER: Keeps dial on time up to 16 hours during power
outage. Add sufx L to model number. Power Consumption: 5 watts.
DIAL: Captivated tabs for setting are easily tilted in or out by hand.
Switch stays ON or OFF as set when adjacent tabs are set alike.
1 TO 48 ON-OFF OPERATIONS PER DAY.
96 tabs permit 15 minute switching changes.
DUTY CYCLES adjustable from 12, 1, 2, 3, 4, 6, 12 and 24 hours.

OPERATING TEMPERATURE RANGE: -40 to +165F. (-40 to +74C.)

ENCLOSURE: See page 27 for dimensions. General purpose (NEMA 1). Drawn steel, beige enamel, with combination 12and
3
4 K.O.s on sides, bottom and back. Lockable hasp. Cover is removable and movement releases from case at nger touch
for easy installation.
WIRING DIAGRAM
OTHER MOUNTINGS: *When ordering special enclosures ONLY, please use model number. ALL SPDT M
Noryl Indoor/Outdoor NEMA 3R: (sufx N) Model 9000N* MODELS

Metal Indoor/Outdoor NEMA 3: (sufx O) Model 9000A*
Flush, with lock and key: (sufx FL1) Model 9001*
Duplex 2 standard units in one indoor/outdoor NEMA 3 metal L
C NC NO
2

case: (sufx DUOL) Model 9004L* H LOAD 2

Bracket mounting specify mechanism only with bracket. 120VAC
CLOSED WITH
TAB OUTWARD

Intermatic Adapter Plate Model IAP allows any TORK 8000 model to N LOAD 1

t into an Intermatic case without changing enclosure CLOSED WITH
TAB INWARD




CAT UPC H.P. MOTOR: MOTOR:
NO CODE SWITCH TYPE AMPS RATING AC VOLTAGE Hz

8001 70001 SPDT 24 Hour 20 3
4 120 60
8004 70002 SPDT 24 Hour 20 3
4 208-277 60
8001U 70003 SPDT 24 Hour 5 3
4 480/120 Trans. 60
8007 70005 SPDT 24 Hour, 7 Day Omit 20 3
4 120 60
8008 70006 SPDT 24 Hour, 7 Day Omit 20 3
4 208-277 60
8007V 70007 SPDT 24 Hour, 14 Day Omit 20 3
4 120 60
WITH RESERVE POWER
8007L 70015 SPDT 24 Hour, 7 Day Omit 20 3/4 120 60
8008L 70016 SPDT 24 Hour, 7 Day Omit 20 3/4 208-277 60
8007VL 70017 SPDT 24 Hour, 14 Day Omit 20 3/4 120 60
24 VOLT IN ALL MODELS AVAILABLE ON SPECIFICATION.



SPECIFICATION WRITERS GUIDE 8000 SERIES
The time switches shall be of duty cycle type, capable of programming at 15-minute intervals of the day. Schedule tabs shall be captive on the dial, and shall be easily set
by hand without tools to obtain or to change the desired schedule. The switching condition shall be maintained when adjacent tabs are set alike. The unit shall be powered
by a self-starting enclosed 120 (or 208-277) volt synchronous motor capable of continuous accurate operation. The switch mechanism shall be a self-contained unit rated at
not less than 20 amps, 120 volts, single pole, double throw, and shall be readily replaceable in the eld.
FOR 8001 ADD: The time switch shall be similar and equal to Tork Model 8001. FOR 8007 AND 8007V ADD: An omitting device shall be furnished as an integral part of
the time switch, to enable the switching operation to be skipped for any preselected day or days of the week. The time switch shall be similar and equal to Tork Model 8007
or (8007V.) FOR 8007L ADD: (Same description as for 8007). The unit shall incorporate an integral electrically wound spring reserve power unit, which shall power the
clock mechanism for up to 16 hours on a power failure. The time switch shall be similar and equal to Tork Model 8007L. FOR 8001U: The unit shall be furnished with built-
in 480-120V transformer to operate timing motor in parallel with 480 volt load. The time switch shall be Tork Model 8001U.


11
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
8000 SERIES
DUTY CYCLE 24 HOUR TIME
SWITCHES
MANY ON/OFF OPERATIONS PER DAY
APPLICATIONS
For one to many daily ON-OFF operations
Duty Cycling Pumping Process Control
Ventilating Fans Irrigation Laboratory
Experiments
SPECIFICATIONS
CONTACT RATINGS: 20 Amps at 120 or 240V, 5 Amps at 480V,
3
4 HP @120V AC
TIMING MOTOR: Heavy duty synchronous, self-starting, high torque.
Power Consumption: 3 watts.
OPTIONAL RESERVE POWER: Keeps dial on time up to 16 hours during power
outage. Add sufx L to model number. Power Consumption: 5 watts.
DIAL: Captivated tabs for setting are easily tilted in or out by hand.
Switch stays ON or OFF as set when adjacent tabs are set alike.
1 TO 48 ON-OFF OPERATIONS PER DAY.
96 tabs permit 15 minute switching changes.
DUTY CYCLES adjustable from 12, 1, 2, 3, 4, 6, 12 and 24 hours.

OPERATING TEMPERATURE RANGE: -40 to +165F. (-40 to +74C.)

ENCLOSURE: See page 27 for dimensions. General purpose (NEMA 1). Drawn steel, beige enamel, with combination 12and
3
4 K.O.s on sides, bottom and back. Lockable hasp. Cover is removable and movement releases from case at nger touch
for easy installation.
WIRING DIAGRAM
OTHER MOUNTINGS: *When ordering special enclosures ONLY, please use model number. ALL SPDT M
Noryl Indoor/Outdoor NEMA 3R: (sufx N) Model 9000N* MODELS

Metal Indoor/Outdoor NEMA 3: (sufx O) Model 9000A*
Flush, with lock and key: (sufx FL1) Model 9001*
Duplex 2 standard units in one indoor/outdoor NEMA 3 metal L
C NC NO
2

case: (sufx DUOL) Model 9004L* H LOAD 2

Bracket mounting specify mechanism only with bracket. 120VAC
CLOSED WITH
TAB OUTWARD

Intermatic Adapter Plate Model IAP allows any TORK 8000 model to N LOAD 1

t into an Intermatic case without changing enclosure CLOSED WITH
TAB INWARD




CAT UPC H.P. MOTOR: MOTOR:
NO CODE SWITCH TYPE AMPS RATING AC VOLTAGE Hz

8001 70001 SPDT 24 Hour 20 3
4 120 60
8004 70002 SPDT 24 Hour 20 3
4 208-277 60
8001U 70003 SPDT 24 Hour 5 3
4 480/120 Trans. 60
8007 70005 SPDT 24 Hour, 7 Day Omit 20 3
4 120 60
8008 70006 SPDT 24 Hour, 7 Day Omit 20 3
4 208-277 60
8007V 70007 SPDT 24 Hour, 14 Day Omit 20 3
4 120 60
WITH RESERVE POWER
8007L 70015 SPDT 24 Hour, 7 Day Omit 20 3/4 120 60
8008L 70016 SPDT 24 Hour, 7 Day Omit 20 3/4 208-277 60
8007VL 70017 SPDT 24 Hour, 14 Day Omit 20 3/4 120 60
24 VOLT IN ALL MODELS AVAILABLE ON SPECIFICATION.



SPECIFICATION WRITERS GUIDE 8000 SERIES
The time switches shall be of duty cycle type, capable of programming at 15-minute intervals of the day. Schedule tabs shall be captive on the dial, and shall be easily set
by hand without tools to obtain or to change the desired schedule. The switching condition shall be maintained when adjacent tabs are set alike. The unit shall be powered
by a self-starting enclosed 120 (or 208-277) volt synchronous motor capable of continuous accurate operation. The switch mechanism shall be a self-contained unit rated at
not less than 20 amps, 120 volts, single pole, double throw, and shall be readily replaceable in the eld.
FOR 8001 ADD: The time switch shall be similar and equal to Tork Model 8001. FOR 8007 AND 8007V ADD: An omitting device shall be furnished as an integral part of
the time switch, to enable the switching operation to be skipped for any preselected day or days of the week. The time switch shall be similar and equal to Tork Model 8007
or (8007V.) FOR 8007L ADD: (Same description as for 8007). The unit shall incorporate an integral electrically wound spring reserve power unit, which shall power the
clock mechanism for up to 16 hours on a power failure. The time switch shall be similar and equal to Tork Model 8007L. FOR 8001U: The unit shall be furnished with built-
in 480-120V transformer to operate timing motor in parallel with 480 volt load. The time switch shall be Tork Model 8001U.


11
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
8000 SERIES
DUTY CYCLE 24 HOUR TIME
SWITCHES
MANY ON/OFF OPERATIONS PER DAY
APPLICATIONS
For one to many daily ON-OFF operations
Duty Cycling Pumping Process Control
Ventilating Fans Irrigation Laboratory
Experiments
SPECIFICATIONS
CONTACT RATINGS: 20 Amps at 120 or 240V, 5 Amps at 480V,
3
4 HP @120V AC
TIMING MOTOR: Heavy duty synchronous, self-starting, high torque.
Power Consumption: 3 watts.
OPTIONAL RESERVE POWER: Keeps dial on time up to 16 hours during power
outage. Add sufx L to model number. Power Consumption: 5 watts.
DIAL: Captivated tabs for setting are easily tilted in or out by hand.
Switch stays ON or OFF as set when adjacent tabs are set alike.
1 TO 48 ON-OFF OPERATIONS PER DAY.
96 tabs permit 15 minute switching changes.
DUTY CYCLES adjustable from 12, 1, 2, 3, 4, 6, 12 and 24 hours.

OPERATING TEMPERATURE RANGE: -40 to +165F. (-40 to +74C.)

ENCLOSURE: See page 27 for dimensions. General purpose (NEMA 1). Drawn steel, beige enamel, with combination 12and
3
4 K.O.s on sides, bottom and back. Lockable hasp. Cover is removable and movement releases from case at nger touch
for easy installation.
WIRING DIAGRAM
OTHER MOUNTINGS: *When ordering special enclosures ONLY, please use model number. ALL SPDT M
Noryl Indoor/Outdoor NEMA 3R: (sufx N) Model 9000N* MODELS

Metal Indoor/Outdoor NEMA 3: (sufx O) Model 9000A*
Flush, with lock and key: (sufx FL1) Model 9001*
Duplex 2 standard units in one indoor/outdoor NEMA 3 metal L
C NC NO
2

case: (sufx DUOL) Model 9004L* H LOAD 2

Bracket mounting specify mechanism only with bracket. 120VAC
CLOSED WITH
TAB OUTWARD

Intermatic Adapter Plate Model IAP allows any TORK 8000 model to N LOAD 1

t into an Intermatic case without changing enclosure CLOSED WITH
TAB INWARD




CAT UPC H.P. MOTOR: MOTOR:
NO CODE SWITCH TYPE AMPS RATING AC VOLTAGE Hz

8001 70001 SPDT 24 Hour 20 3
4 120 60
8004 70002 SPDT 24 Hour 20 3
4 208-277 60
8001U 70003 SPDT 24 Hour 5 3
4 480/120 Trans. 60
8007 70005 SPDT 24 Hour, 7 Day Omit 20 3
4 120 60
8008 70006 SPDT 24 Hour, 7 Day Omit 20 3
4 208-277 60
8007V 70007 SPDT 24 Hour, 14 Day Omit 20 3
4 120 60
WITH RESERVE POWER
8007L 70015 SPDT 24 Hour, 7 Day Omit 20 3/4 120 60
8008L 70016 SPDT 24 Hour, 7 Day Omit 20 3/4 208-277 60
8007VL 70017 SPDT 24 Hour, 14 Day Omit 20 3/4 120 60
24 VOLT IN ALL MODELS AVAILABLE ON SPECIFICATION.



SPECIFICATION WRITERS GUIDE 8000 SERIES
The time switches shall be of duty cycle type, capable of programming at 15-minute intervals of the day. Schedule tabs shall be captive on the dial, and shall be easily set
by hand without tools to obtain or to change the desired schedule. The switching condition shall be maintained when adjacent tabs are set alike. The unit shall be powered
by a self-starting enclosed 120 (or 208-277) volt synchronous motor capable of continuous accurate operation. The switch mechanism shall be a self-contained unit rated at
not less than 20 amps, 120 volts, single pole, double throw, and shall be readily replaceable in the eld.
FOR 8001 ADD: The time switch shall be similar and equal to Tork Model 8001. FOR 8007 AND 8007V ADD: An omitting device shall be furnished as an integral part of
the time switch, to enable the switching operation to be skipped for any preselected day or days of the week. The time switch shall be similar and equal to Tork Model 8007
or (8007V.) FOR 8007L ADD: (Same description as for 8007). The unit shall incorporate an integral electrically wound spring reserve power unit, which shall power the
clock mechanism for up to 16 hours on a power failure. The time switch shall be similar and equal to Tork Model 8007L. FOR 8001U: The unit shall be furnished with built-
in 480-120V transformer to operate timing motor in parallel with 480 volt load. The time switch shall be Tork Model 8001U.


11
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
8000 SERIES
DUTY CYCLE 24 HOUR TIME
SWITCHES
MANY ON/OFF OPERATIONS PER DAY
APPLICATIONS
For one to many daily ON-OFF operations
Duty Cycling Pumping Process Control
Ventilating Fans Irrigation Laboratory
Experiments
SPECIFICATIONS
CONTACT RATINGS: 20 Amps at 120 or 240V, 5 Amps at 480V,
3
4 HP @120V AC
TIMING MOTOR: Heavy duty synchronous, self-starting, high torque.
Power Consumption: 3 watts.
OPTIONAL RESERVE POWER: Keeps dial on time up to 16 hours during power
outage. Add sufx L to model number. Power Consumption: 5 watts.
DIAL: Captivated tabs for setting are easily tilted in or out by hand.
Switch stays ON or OFF as set when adjacent tabs are set alike.
1 TO 48 ON-OFF OPERATIONS PER DAY.
96 tabs permit 15 minute switching changes.
DUTY CYCLES adjustable from 12, 1, 2, 3, 4, 6, 12 and 24 hours.

OPERATING TEMPERATURE RANGE: -40 to +165F. (-40 to +74C.)

ENCLOSURE: See page 27 for dimensions. General purpose (NEMA 1). Drawn steel, beige enamel, with combination 12and
3
4 K.O.s on sides, bottom and back. Lockable hasp. Cover is removable and movement releases from case at nger touch
for easy installation.
WIRING DIAGRAM
OTHER MOUNTINGS: *When ordering special enclosures ONLY, please use model number. ALL SPDT M
Noryl Indoor/Outdoor NEMA 3R: (sufx N) Model 9000N* MODELS

Metal Indoor/Outdoor NEMA 3: (sufx O) Model 9000A*
Flush, with lock and key: (sufx FL1) Model 9001*
Duplex 2 standard units in one indoor/outdoor NEMA 3 metal L
C NC NO
2

case: (sufx DUOL) Model 9004L* H LOAD 2

Bracket mounting specify mechanism only with bracket. 120VAC
CLOSED WITH
TAB OUTWARD

Intermatic Adapter Plate Model IAP allows any TORK 8000 model to N LOAD 1

t into an Intermatic case without changing enclosure CLOSED WITH
TAB INWARD




CAT UPC H.P. MOTOR: MOTOR:
NO CODE SWITCH TYPE AMPS RATING AC VOLTAGE Hz

8001 70001 SPDT 24 Hour 20 3
4 120 60
8004 70002 SPDT 24 Hour 20 3
4 208-277 60
8001U 70003 SPDT 24 Hour 5 3
4 480/120 Trans. 60
8007 70005 SPDT 24 Hour, 7 Day Omit 20 3
4 120 60
8008 70006 SPDT 24 Hour, 7 Day Omit 20 3
4 208-277 60
8007V 70007 SPDT 24 Hour, 14 Day Omit 20 3
4 120 60
WITH RESERVE POWER
8007L 70015 SPDT 24 Hour, 7 Day Omit 20 3/4 120 60
8008L 70016 SPDT 24 Hour, 7 Day Omit 20 3/4 208-277 60
8007VL 70017 SPDT 24 Hour, 14 Day Omit 20 3/4 120 60
24 VOLT IN ALL MODELS AVAILABLE ON SPECIFICATION.



SPECIFICATION WRITERS GUIDE 8000 SERIES
The time switches shall be of duty cycle type, capable of programming at 15-minute intervals of the day. Schedule tabs shall be captive on the dial, and shall be easily set
by hand without tools to obtain or to change the desired schedule. The switching condition shall be maintained when adjacent tabs are set alike. The unit shall be powered
by a self-starting enclosed 120 (or 208-277) volt synchronous motor capable of continuous accurate operation. The switch mechanism shall be a self-contained unit rated at
not less than 20 amps, 120 volts, single pole, double throw, and shall be readily replaceable in the eld.
FOR 8001 ADD: The time switch shall be similar and equal to Tork Model 8001. FOR 8007 AND 8007V ADD: An omitting device shall be furnished as an integral part of
the time switch, to enable the switching operation to be skipped for any preselected day or days of the week. The time switch shall be similar and equal to Tork Model 8007
or (8007V.) FOR 8007L ADD: (Same description as for 8007). The unit shall incorporate an integral electrically wound spring reserve power unit, which shall power the
clock mechanism for up to 16 hours on a power failure. The time switch shall be similar and equal to Tork Model 8007L. FOR 8001U: The unit shall be furnished with built-
in 480-120V transformer to operate timing motor in parallel with 480 volt load. The time switch shall be Tork Model 8001U.


11
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
8000 SERIES
DUTY CYCLE 24 HOUR TIME
SWITCHES
MANY ON/OFF OPERATIONS PER DAY
APPLICATIONS
For one to many daily ON-OFF operations
Duty Cycling Pumping Process Control
Ventilating Fans Irrigation Laboratory
Experiments
SPECIFICATIONS
CONTACT RATINGS: 20 Amps at 120 or 240V, 5 Amps at 480V,
3
4 HP @120V AC
TIMING MOTOR: Heavy duty synchronous, self-starting, high torque.
Power Consumption: 3 watts.
OPTIONAL RESERVE POWER: Keeps dial on time up to 16 hours during power
outage. Add sufx L to model number. Power Consumption: 5 watts.
DIAL: Captivated tabs for setting are easily tilted in or out by hand.
Switch stays ON or OFF as set when adjacent tabs are set alike.
1 TO 48 ON-OFF OPERATIONS PER DAY.
96 tabs permit 15 minute switching changes.
DUTY CYCLES adjustable from 12, 1, 2, 3, 4, 6, 12 and 24 hours.

OPERATING TEMPERATURE RANGE: -40 to +165F. (-40 to +74C.)

ENCLOSURE: See page 27 for dimensions. General purpose (NEMA 1). Drawn steel, beige enamel, with combination 12and
3
4 K.O.s on sides, bottom and back. Lockable hasp. Cover is removable and movement releases from case at nger touch
for easy installation.
WIRING DIAGRAM
OTHER MOUNTINGS: *When ordering special enclosures ONLY, please use model number. ALL SPDT M
Noryl Indoor/Outdoor NEMA 3R: (sufx N) Model 9000N* MODELS

Metal Indoor/Outdoor NEMA 3: (sufx O) Model 9000A*
Flush, with lock and key: (sufx FL1) Model 9001*
Duplex 2 standard units in one indoor/outdoor NEMA 3 metal L
C NC NO
2

case: (sufx DUOL) Model 9004L* H LOAD 2

Bracket mounting specify mechanism only with bracket. 120VAC
CLOSED WITH
TAB OUTWARD

Intermatic Adapter Plate Model IAP allows any TORK 8000 model to N LOAD 1

t into an Intermatic case without changing enclosure CLOSED WITH
TAB INWARD




CAT UPC H.P. MOTOR: MOTOR:
NO CODE SWITCH TYPE AMPS RATING AC VOLTAGE Hz

8001 70001 SPDT 24 Hour 20 3
4 120 60
8004 70002 SPDT 24 Hour 20 3
4 208-277 60
8001U 70003 SPDT 24 Hour 5 3
4 480/120 Trans. 60
8007 70005 SPDT 24 Hour, 7 Day Omit 20 3
4 120 60
8008 70006 SPDT 24 Hour, 7 Day Omit 20 3
4 208-277 60
8007V 70007 SPDT 24 Hour, 14 Day Omit 20 3
4 120 60
WITH RESERVE POWER
8007L 70015 SPDT 24 Hour, 7 Day Omit 20 3/4 120 60
8008L 70016 SPDT 24 Hour, 7 Day Omit 20 3/4 208-277 60
8007VL 70017 SPDT 24 Hour, 14 Day Omit 20 3/4 120 60
24 VOLT IN ALL MODELS AVAILABLE ON SPECIFICATION.



SPECIFICATION WRITERS GUIDE 8000 SERIES
The time switches shall be of duty cycle type, capable of programming at 15-minute intervals of the day. Schedule tabs shall be captive on the dial, and shall be easily set
by hand without tools to obtain or to change the desired schedule. The switching condition shall be maintained when adjacent tabs are set alike. The unit shall be powered
by a self-starting enclosed 120 (or 208-277) volt synchronous motor capable of continuous accurate operation. The switch mechanism shall be a self-contained unit rated at
not less than 20 amps, 120 volts, single pole, double throw, and shall be readily replaceable in the eld.
FOR 8001 ADD: The time switch shall be similar and equal to Tork Model 8001. FOR 8007 AND 8007V ADD: An omitting device shall be furnished as an integral part of
the time switch, to enable the switching operation to be skipped for any preselected day or days of the week. The time switch shall be similar and equal to Tork Model 8007
or (8007V.) FOR 8007L ADD: (Same description as for 8007). The unit shall incorporate an integral electrically wound spring reserve power unit, which shall power the
clock mechanism for up to 16 hours on a power failure. The time switch shall be similar and equal to Tork Model 8007L. FOR 8001U: The unit shall be furnished with built-
in 480-120V transformer to operate timing motor in parallel with 480 volt load. The time switch shall be Tork Model 8001U.


11
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
8000 SERIES
DUTY CYCLE 24 HOUR TIME
SWITCHES
MANY ON/OFF OPERATIONS PER DAY
APPLICATIONS
For one to many daily ON-OFF operations
Duty Cycling Pumping Process Control
Ventilating Fans Irrigation Laboratory
Experiments
SPECIFICATIONS
CONTACT RATINGS: 20 Amps at 120 or 240V, 5 Amps at 480V,
3
4 HP @120V AC
TIMING MOTOR: Heavy duty synchronous, self-starting, high torque.
Power Consumption: 3 watts.
OPTIONAL RESERVE POWER: Keeps dial on time up to 16 hours during power
outage. Add sufx L to model number. Power Consumption: 5 watts.
DIAL: Captivated tabs for setting are easily tilted in or out by hand.
Switch stays ON or OFF as set when adjacent tabs are set alike.
1 TO 48 ON-OFF OPERATIONS PER DAY.
96 tabs permit 15 minute switching changes.
DUTY CYCLES adjustable from 12, 1, 2, 3, 4, 6, 12 and 24 hours.

OPERATING TEMPERATURE RANGE: -40 to +165F. (-40 to +74C.)

ENCLOSURE: See page 27 for dimensions. General purpose (NEMA 1). Drawn steel, beige enamel, with combination 12and
3
4 K.O.s on sides, bottom and back. Lockable hasp. Cover is removable and movement releases from case at nger touch
for easy installation.
WIRING DIAGRAM
OTHER MOUNTINGS: *When ordering special enclosures ONLY, please use model number. ALL SPDT M
Noryl Indoor/Outdoor NEMA 3R: (sufx N) Model 9000N* MODELS

Metal Indoor/Outdoor NEMA 3: (sufx O) Model 9000A*
Flush, with lock and key: (sufx FL1) Model 9001*
Duplex 2 standard units in one indoor/outdoor NEMA 3 metal L
C NC NO
2

case: (sufx DUOL) Model 9004L* H LOAD 2

Bracket mounting specify mechanism only with bracket. 120VAC
CLOSED WITH
TAB OUTWARD

Intermatic Adapter Plate Model IAP allows any TORK 8000 model to N LOAD 1

t into an Intermatic case without changing enclosure CLOSED WITH
TAB INWARD




CAT UPC H.P. MOTOR: MOTOR:
NO CODE SWITCH TYPE AMPS RATING AC VOLTAGE Hz

8001 70001 SPDT 24 Hour 20 3
4 120 60
8004 70002 SPDT 24 Hour 20 3
4 208-277 60
8001U 70003 SPDT 24 Hour 5 3
4 480/120 Trans. 60
8007 70005 SPDT 24 Hour, 7 Day Omit 20 3
4 120 60
8008 70006 SPDT 24 Hour, 7 Day Omit 20 3
4 208-277 60
8007V 70007 SPDT 24 Hour, 14 Day Omit 20 3
4 120 60
WITH RESERVE POWER
8007L 70015 SPDT 24 Hour, 7 Day Omit 20 3/4 120 60
8008L 70016 SPDT 24 Hour, 7 Day Omit 20 3/4 208-277 60
8007VL 70017 SPDT 24 Hour, 14 Day Omit 20 3/4 120 60
24 VOLT IN ALL MODELS AVAILABLE ON SPECIFICATION.



SPECIFICATION WRITERS GUIDE 8000 SERIES
The time switches shall be of duty cycle type, capable of programming at 15-minute intervals of the day. Schedule tabs shall be captive on the dial, and shall be easily set
by hand without tools to obtain or to change the desired schedule. The switching condition shall be maintained when adjacent tabs are set alike. The unit shall be powered
by a self-starting enclosed 120 (or 208-277) volt synchronous motor capable of continuous accurate operation. The switch mechanism shall be a self-contained unit rated at
not less than 20 amps, 120 volts, single pole, double throw, and shall be readily replaceable in the eld.
FOR 8001 ADD: The time switch shall be similar and equal to Tork Model 8001. FOR 8007 AND 8007V ADD: An omitting device shall be furnished as an integral part of
the time switch, to enable the switching operation to be skipped for any preselected day or days of the week. The time switch shall be similar and equal to Tork Model 8007
or (8007V.) FOR 8007L ADD: (Same description as for 8007). The unit shall incorporate an integral electrically wound spring reserve power unit, which shall power the
clock mechanism for up to 16 hours on a power failure. The time switch shall be similar and equal to Tork Model 8007L. FOR 8001U: The unit shall be furnished with built-
in 480-120V transformer to operate timing motor in parallel with 480 volt load. The time switch shall be Tork Model 8001U.


11
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
8000 SERIES
DUTY CYCLE 24 HOUR TIME
SWITCHES
MANY ON/OFF OPERATIONS PER DAY
APPLICATIONS
For one to many daily ON-OFF operations
Duty Cycling Pumping Process Control
Ventilating Fans Irrigation Laboratory
Experiments
SPECIFICATIONS
CONTACT RATINGS: 20 Amps at 120 or 240V, 5 Amps at 480V,
3
4 HP @120V AC
TIMING MOTOR: Heavy duty synchronous, self-starting, high torque.
Power Consumption: 3 watts.
OPTIONAL RESERVE POWER: Keeps dial on time up to 16 hours during power
outage. Add sufx L to model number. Power Consumption: 5 watts.
DIAL: Captivated tabs for setting are easily tilted in or out by hand.
Switch stays ON or OFF as set when adjacent tabs are set alike.
1 TO 48 ON-OFF OPERATIONS PER DAY.
96 tabs permit 15 minute switching changes.
DUTY CYCLES adjustable from 12, 1, 2, 3, 4, 6, 12 and 24 hours.

OPERATING TEMPERATURE RANGE: -40 to +165F. (-40 to +74C.)

ENCLOSURE: See page 27 for dimensions. General purpose (NEMA 1). Drawn steel, beige enamel, with combination 12and
3
4 K.O.s on sides, bottom and back. Lockable hasp. Cover is removable and movement releases from case at nger touch
for easy installation.
WIRING DIAGRAM
OTHER MOUNTINGS: *When ordering special enclosures ONLY, please use model number. ALL SPDT M
Noryl Indoor/Outdoor NEMA 3R: (sufx N) Model 9000N* MODELS

Metal Indoor/Outdoor NEMA 3: (sufx O) Model 9000A*
Flush, with lock and key: (sufx FL1) Model 9001*
Duplex 2 standard units in one indoor/outdoor NEMA 3 metal L
C NC NO
2

case: (sufx DUOL) Model 9004L* H LOAD 2

Bracket mounting specify mechanism only with bracket. 120VAC
CLOSED WITH
TAB OUTWARD

Intermatic Adapter Plate Model IAP allows any TORK 8000 model to N LOAD 1

t into an Intermatic case without changing enclosure CLOSED WITH
TAB INWARD




CAT UPC H.P. MOTOR: MOTOR:
NO CODE SWITCH TYPE AMPS RATING AC VOLTAGE Hz

8001 70001 SPDT 24 Hour 20 3
4 120 60
8004 70002 SPDT 24 Hour 20 3
4 208-277 60
8001U 70003 SPDT 24 Hour 5 3
4 480/120 Trans. 60
8007 70005 SPDT 24 Hour, 7 Day Omit 20 3
4 120 60
8008 70006 SPDT 24 Hour, 7 Day Omit 20 3
4 208-277 60
8007V 70007 SPDT 24 Hour, 14 Day Omit 20 3
4 120 60
WITH RESERVE POWER
8007L 70015 SPDT 24 Hour, 7 Day Omit 20 3/4 120 60
8008L 70016 SPDT 24 Hour, 7 Day Omit 20 3/4 208-277 60
8007VL 70017 SPDT 24 Hour, 14 Day Omit 20 3/4 120 60
24 VOLT IN ALL MODELS AVAILABLE ON SPECIFICATION.



SPECIFICATION WRITERS GUIDE 8000 SERIES
The time switches shall be of duty cycle type, capable of programming at 15-minute intervals of the day. Schedule tabs shall be captive on the dial, and shall be easily set
by hand without tools to obtain or to change the desired schedule. The switching condition shall be maintained when adjacent tabs are set alike. The unit shall be powered
by a self-starting enclosed 120 (or 208-277) volt synchronous motor capable of continuous accurate operation. The switch mechanism shall be a self-contained unit rated at
not less than 20 amps, 120 volts, single pole, double throw, and shall be readily replaceable in the eld.
FOR 8001 ADD: The time switch shall be similar and equal to Tork Model 8001. FOR 8007 AND 8007V ADD: An omitting device shall be furnished as an integral part of
the time switch, to enable the switching operation to be skipped for any preselected day or days of the week. The time switch shall be similar and equal to Tork Model 8007
or (8007V.) FOR 8007L ADD: (Same description as for 8007). The unit shall incorporate an integral electrically wound spring reserve power unit, which shall power the
clock mechanism for up to 16 hours on a power failure. The time switch shall be similar and equal to Tork Model 8007L. FOR 8001U: The unit shall be furnished with built-
in 480-120V transformer to operate timing motor in parallel with 480 volt load. The time switch shall be Tork Model 8001U.


11
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
8000 SERIES
DUTY CYCLE 24 HOUR TIME
SWITCHES
MANY ON/OFF OPERATIONS PER DAY
APPLICATIONS
For one to many daily ON-OFF operations
Duty Cycling Pumping Process Control
Ventilating Fans Irrigation Laboratory
Experiments
SPECIFICATIONS
CONTACT RATINGS: 20 Amps at 120 or 240V, 5 Amps at 480V,
3
4 HP @120V AC
TIMING MOTOR: Heavy duty synchronous, self-starting, high torque.
Power Consumption: 3 watts.
OPTIONAL RESERVE POWER: Keeps dial on time up to 16 hours during power
outage. Add sufx L to model number. Power Consumption: 5 watts.
DIAL: Captivated tabs for setting are easily tilted in or out by hand.
Switch stays ON or OFF as set when adjacent tabs are set alike.
1 TO 48 ON-OFF OPERATIONS PER DAY.
96 tabs permit 15 minute switching changes.
DUTY CYCLES adjustable from 12, 1, 2, 3, 4, 6, 12 and 24 hours.

OPERATING TEMPERATURE RANGE: -40 to +165F. (-40 to +74C.)

ENCLOSURE: See page 27 for dimensions. General purpose (NEMA 1). Drawn steel, beige enamel, with combination 12and
3
4 K.O.s on sides, bottom and back. Lockable hasp. Cover is removable and movement releases from case at nger touch
for easy installation.
WIRING DIAGRAM
OTHER MOUNTINGS: *When ordering special enclosures ONLY, please use model number. ALL SPDT M
Noryl Indoor/Outdoor NEMA 3R: (sufx N) Model 9000N* MODELS

Metal Indoor/Outdoor NEMA 3: (sufx O) Model 9000A*
Flush, with lock and key: (sufx FL1) Model 9001*
Duplex 2 standard units in one indoor/outdoor NEMA 3 metal L
C NC NO
2

case: (sufx DUOL) Model 9004L* H LOAD 2

Bracket mounting specify mechanism only with bracket. 120VAC
CLOSED WITH
TAB OUTWARD

Intermatic Adapter Plate Model IAP allows any TORK 8000 model to N LOAD 1

t into an Intermatic case without changing enclosure CLOSED WITH
TAB INWARD




CAT UPC H.P. MOTOR: MOTOR:
NO CODE SWITCH TYPE AMPS RATING AC VOLTAGE Hz

8001 70001 SPDT 24 Hour 20 3
4 120 60
8004 70002 SPDT 24 Hour 20 3
4 208-277 60
8001U 70003 SPDT 24 Hour 5 3
4 480/120 Trans. 60
8007 70005 SPDT 24 Hour, 7 Day Omit 20 3
4 120 60
8008 70006 SPDT 24 Hour, 7 Day Omit 20 3
4 208-277 60
8007V 70007 SPDT 24 Hour, 14 Day Omit 20 3
4 120 60
WITH RESERVE POWER
8007L 70015 SPDT 24 Hour, 7 Day Omit 20 3/4 120 60
8008L 70016 SPDT 24 Hour, 7 Day Omit 20 3/4 208-277 60
8007VL 70017 SPDT 24 Hour, 14 Day Omit 20 3/4 120 60
24 VOLT IN ALL MODELS AVAILABLE ON SPECIFICATION.



SPECIFICATION WRITERS GUIDE 8000 SERIES
The time switches shall be of duty cycle type, capable of programming at 15-minute intervals of the day. Schedule tabs shall be captive on the dial, and shall be easily set
by hand without tools to obtain or to change the desired schedule. The switching condition shall be maintained when adjacent tabs are set alike. The unit shall be powered
by a self-starting enclosed 120 (or 208-277) volt synchronous motor capable of continuous accurate operation. The switch mechanism shall be a self-contained unit rated at
not less than 20 amps, 120 volts, single pole, double throw, and shall be readily replaceable in the eld.
FOR 8001 ADD: The time switch shall be similar and equal to Tork Model 8001. FOR 8007 AND 8007V ADD: An omitting device shall be furnished as an integral part of
the time switch, to enable the switching operation to be skipped for any preselected day or days of the week. The time switch shall be similar and equal to Tork Model 8007
or (8007V.) FOR 8007L ADD: (Same description as for 8007). The unit shall incorporate an integral electrically wound spring reserve power unit, which shall power the
clock mechanism for up to 16 hours on a power failure. The time switch shall be similar and equal to Tork Model 8007L. FOR 8001U: The unit shall be furnished with built-
in 480-120V transformer to operate timing motor in parallel with 480 volt load. The time switch shall be Tork Model 8001U.


11
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
ACCESSORIES
CAT UPC
NO CODE DESCRIPTION

PK100 95110 Parts Kit includes parts cabinet and 24 P47, 5 P49, 28 P69, 10 P14, 4 101M motors, 2 201M motors.
P-47 95001 Pair Standard Screw-On Type Trippers for 1100 Series (except FM models)
and all 7000 and 1800 Series models. Does not advance day omitting wheel.
K24 95026 Kit of 24 pairs of P-47 Trippers.
PF48 95003 Pair of standard trippers for 1100 FM Series.
P-49 95002 Special ON tripper for 7000 Series to also advance day omitting wheel. Standard OFF tripper included.
P-69 85003 Screw-On Type Trippers reversible ON and OFF for use on all models with 612 dia.
7 day dial (except W400 Series). Available only in packages of 7 pairs.
P-69I 85004 ON and OFF Trippers for W400 Series. Available only in packages of 7 pairs.
P-41 95400 ON & OFF trippers for plug-in timers Models 401, 421, 431.
P-14 95006 Omitting screws for inserting into tapped hole of appropriate spoke of day omitting wheel. Color: Black.
P-26 95007 Selector screws for 4000 (Double Dial) Series Provides Extra Operations Daily. Color: Copper
KN500 95027 For 2 conduit. Grounding bushings for use with Noryl enclosures and metal conduit. Fits #10-14 AWG ground wires. 2 bushings per kit.
1


KN750 95028 For 34 conduit. Grounding bushings for use with Noryl enclosures and metal conduit. Fits #10-14 AWG ground wires. 2 bushings per kit.
64140 95008 480/120v Step-down Transformer only for 480v power input. 7.8 VA (for use with Model 7100, 8001, 8007 only).
71018 95009 24/120V Step-up Transformer. 50VA.



Mounting Brackets for mounting unit less case. Specify CAT UPC
model number, date of manufacture, and whether NO CODE DESCRIPTION
model mounts by snapping into case, or with screws.

MODEL NO: 65447 70159 95050 W. Dial for T900, TW, 1847AW,
and W controls except W400A
UPC CODE: 95020
All 24 hour models except 3-pole, 73713-4 95051 24 hour dial for 7100 Series
including reserve power models 73713-5 95052 24 hour dial for 1100 Series, 1847A Series
53032-17 95053 FM Series dial for 1100FM; 1100FMM
MODEL NO: 64040 (CK-7300) 64041 95054 8001 Dial
UPC CODE: 95023
64041-1 95055 8007 Dial
24 Hour 3-pole for Models 7300, 7302.
64041-2 95056 8601 Dial
64041-6 95059 8301 Dial
MODEL NO: 64039
64041-5 95058 8121 Dial
UPC CODE: 95021
for W SERIES 7 Day Models: 64041-4 95057 8061 Dial
W100, W200, W202, W120, W220, W222. 73855 95060 Wallplate for 701A
73856-1 95061 Wallplate for 701A-2G
MODEL NO: 62153-1 90031-17 95062 Relay for T-900 Series
UPC CODE: 95022 74240-2 95063 White Knob for A500 Series
W SERIES 7 Day 3-pole for Models W300, 74240-I 95064 Ivory Knob for A500 Series
W302.
74240-3 95065 Black Knob for C500 Series
59201-1 95024 Micro-switch for 8001 and M8000 units
59201-26 95025 Micro-switch for 8007 units
73192-3 95030 Adapter plate allows DG series to snap into
7 day (W Series) Time Switch Enclosure




25
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
ACCESSORIES
CAT UPC
NO CODE DESCRIPTION

PK100 95110 Parts Kit includes parts cabinet and 24 P47, 5 P49, 28 P69, 10 P14, 4 101M motors, 2 201M motors.
P-47 95001 Pair Standard Screw-On Type Trippers for 1100 Series (except FM models)
and all 7000 and 1800 Series models. Does not advance day omitting wheel.
K24 95026 Kit of 24 pairs of P-47 Trippers.
PF48 95003 Pair of standard trippers for 1100 FM Series.
P-49 95002 Special ON tripper for 7000 Series to also advance day omitting wheel. Standard OFF tripper included.
P-69 85003 Screw-On Type Trippers reversible ON and OFF for use on all models with 612 dia.
7 day dial (except W400 Series). Available only in packages of 7 pairs.
P-69I 85004 ON and OFF Trippers for W400 Series. Available only in packages of 7 pairs.
P-41 95400 ON & OFF trippers for plug-in timers Models 401, 421, 431.
P-14 95006 Omitting screws for inserting into tapped hole of appropriate spoke of day omitting wheel. Color: Black.
P-26 95007 Selector screws for 4000 (Double Dial) Series Provides Extra Operations Daily. Color: Copper
KN500 95027 For 2 conduit. Grounding bushings for use with Noryl enclosures and metal conduit. Fits #10-14 AWG ground wires. 2 bushings per kit.
1


KN750 95028 For 34 conduit. Grounding bushings for use with Noryl enclosures and metal conduit. Fits #10-14 AWG ground wires. 2 bushings per kit.
64140 95008 480/120v Step-down Transformer only for 480v power input. 7.8 VA (for use with Model 7100, 8001, 8007 only).
71018 95009 24/120V Step-up Transformer. 50VA.



Mounting Brackets for mounting unit less case. Specify CAT UPC
model number, date of manufacture, and whether NO CODE DESCRIPTION
model mounts by snapping into case, or with screws.

MODEL NO: 65447 70159 95050 W. Dial for T900, TW, 1847AW,
and W controls except W400A
UPC CODE: 95020
All 24 hour models except 3-pole, 73713-4 95051 24 hour dial for 7100 Series
including reserve power models 73713-5 95052 24 hour dial for 1100 Series, 1847A Series
53032-17 95053 FM Series dial for 1100FM; 1100FMM
MODEL NO: 64040 (CK-7300) 64041 95054 8001 Dial
UPC CODE: 95023
64041-1 95055 8007 Dial
24 Hour 3-pole for Models 7300, 7302.
64041-2 95056 8601 Dial
64041-6 95059 8301 Dial
MODEL NO: 64039
64041-5 95058 8121 Dial
UPC CODE: 95021
for W SERIES 7 Day Models: 64041-4 95057 8061 Dial
W100, W200, W202, W120, W220, W222. 73855 95060 Wallplate for 701A
73856-1 95061 Wallplate for 701A-2G
MODEL NO: 62153-1 90031-17 95062 Relay for T-900 Series
UPC CODE: 95022 74240-2 95063 White Knob for A500 Series
W SERIES 7 Day 3-pole for Models W300, 74240-I 95064 Ivory Knob for A500 Series
W302.
74240-3 95065 Black Knob for C500 Series
59201-1 95024 Micro-switch for 8001 and M8000 units
59201-26 95025 Micro-switch for 8007 units
73192-3 95030 Adapter plate allows DG series to snap into
7 day (W Series) Time Switch Enclosure




25
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
ACCESSORIES
CAT UPC
NO CODE DESCRIPTION

PK100 95110 Parts Kit includes parts cabinet and 24 P47, 5 P49, 28 P69, 10 P14, 4 101M motors, 2 201M motors.
P-47 95001 Pair Standard Screw-On Type Trippers for 1100 Series (except FM models)
and all 7000 and 1800 Series models. Does not advance day omitting wheel.
K24 95026 Kit of 24 pairs of P-47 Trippers.
PF48 95003 Pair of standard trippers for 1100 FM Series.
P-49 95002 Special ON tripper for 7000 Series to also advance day omitting wheel. Standard OFF tripper included.
P-69 85003 Screw-On Type Trippers reversible ON and OFF for use on all models with 612 dia.
7 day dial (except W400 Series). Available only in packages of 7 pairs.
P-69I 85004 ON and OFF Trippers for W400 Series. Available only in packages of 7 pairs.
P-41 95400 ON & OFF trippers for plug-in timers Models 401, 421, 431.
P-14 95006 Omitting screws for inserting into tapped hole of appropriate spoke of day omitting wheel. Color: Black.
P-26 95007 Selector screws for 4000 (Double Dial) Series Provides Extra Operations Daily. Color: Copper
KN500 95027 For 2 conduit. Grounding bushings for use with Noryl enclosures and metal conduit. Fits #10-14 AWG ground wires. 2 bushings per kit.
1


KN750 95028 For 34 conduit. Grounding bushings for use with Noryl enclosures and metal conduit. Fits #10-14 AWG ground wires. 2 bushings per kit.
64140 95008 480/120v Step-down Transformer only for 480v power input. 7.8 VA (for use with Model 7100, 8001, 8007 only).
71018 95009 24/120V Step-up Transformer. 50VA.



Mounting Brackets for mounting unit less case. Specify CAT UPC
model number, date of manufacture, and whether NO CODE DESCRIPTION
model mounts by snapping into case, or with screws.

MODEL NO: 65447 70159 95050 W. Dial for T900, TW, 1847AW,
and W controls except W400A
UPC CODE: 95020
All 24 hour models except 3-pole, 73713-4 95051 24 hour dial for 7100 Series
including reserve power models 73713-5 95052 24 hour dial for 1100 Series, 1847A Series
53032-17 95053 FM Series dial for 1100FM; 1100FMM
MODEL NO: 64040 (CK-7300) 64041 95054 8001 Dial
UPC CODE: 95023
64041-1 95055 8007 Dial
24 Hour 3-pole for Models 7300, 7302.
64041-2 95056 8601 Dial
64041-6 95059 8301 Dial
MODEL NO: 64039
64041-5 95058 8121 Dial
UPC CODE: 95021
for W SERIES 7 Day Models: 64041-4 95057 8061 Dial
W100, W200, W202, W120, W220, W222. 73855 95060 Wallplate for 701A
73856-1 95061 Wallplate for 701A-2G
MODEL NO: 62153-1 90031-17 95062 Relay for T-900 Series
UPC CODE: 95022 74240-2 95063 White Knob for A500 Series
W SERIES 7 Day 3-pole for Models W300, 74240-I 95064 Ivory Knob for A500 Series
W302.
74240-3 95065 Black Knob for C500 Series
59201-1 95024 Micro-switch for 8001 and M8000 units
59201-26 95025 Micro-switch for 8007 units
73192-3 95030 Adapter plate allows DG series to snap into
7 day (W Series) Time Switch Enclosure




25
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
ENCLOSURE & MECHANISM DIMENSIONS
METAL INDOOR NEMA 1 METAL INDOOR/OUTDOOR 5-1/4"

#68229 NEMA 3
STD. FOR
MODELS
4-11/16" Model 9000A Suffix O 8-1/4"
1101 7200 8121
1102 7202 8301 STD. FOR MODELS
1103 7120 8601 7-15/16"
7300, (L) 7302Z
1104 7122 8602 7302, (L) 7300ZL 4-5/8"


1101FM 8001 TORK 7300Z 7302ZL
1104FM 8004
AVAILABLE FOR MODELS
7100 8061
2-15/16" 1101 7200, (L,Z,ZL) 1847AL 8007V
7102 1102 7202, (L,Z,ZL) 1847AZL 8061
1103 7120, (L,Z,ZL) 8001 8121
1104 7122, (L,ZL) 8004 8301
1101FM 7220, (L) 8001U 8601
1104FM 7222, (L) 8007 8602
METAL INDOOR NEMA 1 7100 1847A 8007L
#63100 7102 1847AZ
5"
STD. FOR MODELS
7220, (L) 1847AL
7222, (L) 1847AZL
7200L 8007 9-1/4"
7202L 8007L
METAL INDOOR/OUTDOOR
7120L 8007V
NEMA 3 8-3/8 "


1847A 8150
TORK
Model 9006 Suffix O
1848A 8150U AVAILABLE FOR MODELS
1849A W100 W220 TW220L 13-1/8"

3-3/4" W200 W222 TW300L
1847AZ
W202 W220L T920L
W300 W222L T930L
W302 W300L 1847AW
W120 W302L 1847AWL 5-3/16 "

METAL INDOOR NEMA 1
#63016-1 8-1/8"


STD. FOR MODELS
TZ220L W302L
5"
12-1/8 "
TZ300L TW220L NORYL INDOOR/OUTDOOR


W300 TW300L
TORK NEMA 3R
W302 T920L
W300L T930L
Model 9000N Suffix N 9-1/8"


STD. FOR MODELS
4-3/4"
7200Z,(L, ZL) TORK


7202Z,(L, ZL)
7120Z,(L, ZL)
4-1/2"
7122Z, (L, ZL)
METAL INDOOR NEMA 1 AVAILABLE FOR MODELS
#70100 7-5/8 " 1101 7102 7222, (L) 8001U
1102 7200, (L) 1847A 8061
STD. FOR MODELS 1103 7202, (L) 1847AZ 8121
W100 W222 1104 7120, (L) 1847AL 8301
1101FM 7122, (L) 1847AZL 8601
W200 W220L
11-7/8 "
1104FM 7220, (L) 8001 8602
W202 W222L 7100 8004
W120 1847AW TORK



W220 1847AWL

3-1/4 "




METAL INDOOR NEMA 1 NORYL & LEXAN 5"

for W400 Series NEMA 3R
12 -1/2" INDOOR/OUTDOOR TORK 9-1/8"
STD. FOR MODELS Model 9000NC
W400A W400AL
STD. FOR MODELS
W402A W402AL 1101NC
4" 1103NC
4-1/2"
8 -1/4" 1104NC




26
A DIVISION OF NSi INDUSTRIES, LLC
ENCLOSURE & MECHANISM DIMENSIONS
METAL INDOOR NEMA 1 METAL INDOOR/OUTDOOR 5-1/4"

#68229 NEMA 3
STD. FOR
MODELS
4-11/16" Model 9000A Suffix O 8-1/4"
1101 7200 8121
1102 7202 8301 STD. FOR MODELS
1103 7120 8601 7-15/16"
7300, (L) 7302Z
1104 7122 8602 7302, (L) 7300ZL 4-5/8"


1101FM 8001 TORK 7300Z 7302ZL
1104FM 8004
AVAILABLE FOR MODELS
7100 8061
2-15/16" 1101 7200, (L,Z,ZL) 1847AL 8007V
7102 1102 7202, (L,Z,ZL) 1847AZL 8061
1103 7120, (L,Z,ZL) 8001 8121
1104 7122, (L,ZL) 8004 8301
1101FM 7220, (L) 8001U 8601
1104FM 7222, (L) 8007 8602
METAL INDOOR NEMA 1 7100 1847A 8007L
#63100 7102 1847AZ
5"
STD. FOR MODELS
7220, (L) 1847AL
7222, (L) 1847AZL
7200L 8007 9-1/4"
7202L 8007L
METAL INDOOR/OUTDOOR
7120L 8007V
NEMA 3 8-3/8 "


1847A 8150
TORK
Model 9006 Suffix O
1848A 8150U AVAILABLE FOR MODELS
1849A W100 W220 TW220L 13-1/8"

3-3/4" W200 W222 TW300L
1847AZ
W202 W220L T920L
W300 W222L T930L
W302 W300L 1847AW
W120 W302L 1847AWL 5-3/16 "

METAL INDOOR NEMA 1
#63016-1 8-1/8"


STD. FOR MODELS
TZ220L W302L
5"
12-1/8 "
TZ300L TW220L NORYL INDOOR/OUTDOOR


W300 TW300L
TORK NEMA 3R
W302 T920L
W300L T930L
Model 9000N Suffix N 9-1/8"


STD. FOR MODELS
4-3/4"
7200Z,(L, ZL) TORK


7202Z,(L, ZL)
7120Z,(L, ZL)
4-1/2"
7122Z, (L, ZL)
METAL INDOOR NEMA 1 AVAILABLE FOR MODELS
#70100 7-5/8 " 1101 7102 7222, (L) 8001U
1102 7200, (L) 1847A 8061
STD. FOR MODELS 1103 7202, (L) 1847AZ 8121
W100 W222 1104 7120, (L) 1847AL 8301
1101FM 7122, (L) 1847AZL 8601
W200 W220L
11-7/8 "
1104FM 7220, (L) 8001 8602
W202 W222L 7100 8004
W120 1847AW TORK



W220 1847AWL

3-1/4 "




METAL INDOOR NEMA 1 NORYL & LEXAN 5"

for W400 Series NEMA 3R
12 -1/2" INDOOR/OUTDOOR TORK 9-1/8"
STD. FOR MODELS Model 9000NC
W400A W400AL
STD. FOR MODELS
W402A W402AL 1101NC
4" 1103NC
4-1/2"
8 -1/4" 1104NC




26
A DIVISION OF NSi INDUSTRIES, LLC
ENCLOSURE & MECHANISM DIMENSIONS
METAL INDOOR NEMA 1 METAL INDOOR/OUTDOOR 5-1/4"

#68229 NEMA 3
STD. FOR
MODELS
4-11/16" Model 9000A Suffix O 8-1/4"
1101 7200 8121
1102 7202 8301 STD. FOR MODELS
1103 7120 8601 7-15/16"
7300, (L) 7302Z
1104 7122 8602 7302, (L) 7300ZL 4-5/8"


1101FM 8001 TORK 7300Z 7302ZL
1104FM 8004
AVAILABLE FOR MODELS
7100 8061
2-15/16" 1101 7200, (L,Z,ZL) 1847AL 8007V
7102 1102 7202, (L,Z,ZL) 1847AZL 8061
1103 7120, (L,Z,ZL) 8001 8121
1104 7122, (L,ZL) 8004 8301
1101FM 7220, (L) 8001U 8601
1104FM 7222, (L) 8007 8602
METAL INDOOR NEMA 1 7100 1847A 8007L
#63100 7102 1847AZ
5"
STD. FOR MODELS
7220, (L) 1847AL
7222, (L) 1847AZL
7200L 8007 9-1/4"
7202L 8007L
METAL INDOOR/OUTDOOR
7120L 8007V
NEMA 3 8-3/8 "


1847A 8150
TORK
Model 9006 Suffix O
1848A 8150U AVAILABLE FOR MODELS
1849A W100 W220 TW220L 13-1/8"

3-3/4" W200 W222 TW300L
1847AZ
W202 W220L T920L
W300 W222L T930L
W302 W300L 1847AW
W120 W302L 1847AWL 5-3/16 "

METAL INDOOR NEMA 1
#63016-1 8-1/8"


STD. FOR MODELS
TZ220L W302L
5"
12-1/8 "
TZ300L TW220L NORYL INDOOR/OUTDOOR


W300 TW300L
TORK NEMA 3R
W302 T920L
W300L T930L
Model 9000N Suffix N 9-1/8"


STD. FOR MODELS
4-3/4"
7200Z,(L, ZL) TORK


7202Z,(L, ZL)
7120Z,(L, ZL)
4-1/2"
7122Z, (L, ZL)
METAL INDOOR NEMA 1 AVAILABLE FOR MODELS
#70100 7-5/8 " 1101 7102 7222, (L) 8001U
1102 7200, (L) 1847A 8061
STD. FOR MODELS 1103 7202, (L) 1847AZ 8121
W100 W222 1104 7120, (L) 1847AL 8301
1101FM 7122, (L) 1847AZL 8601
W200 W220L
11-7/8 "
1104FM 7220, (L) 8001 8602
W202 W222L 7100 8004
W120 1847AW TORK



W220 1847AWL

3-1/4 "




METAL INDOOR NEMA 1 NORYL & LEXAN 5"

for W400 Series NEMA 3R
12 -1/2" INDOOR/OUTDOOR TORK 9-1/8"
STD. FOR MODELS Model 9000NC
W400A W400AL
STD. FOR MODELS
W402A W402AL 1101NC
4" 1103NC
4-1/2"
8 -1/4" 1104NC




26
A DIVISION OF NSi INDUSTRIES, LLC
ENCLOSURE & MECHANISM DIMENSIONS
METAL INDOOR NEMA 1 METAL INDOOR/OUTDOOR 5-1/4"

#68229 NEMA 3
STD. FOR
MODELS
4-11/16" Model 9000A Suffix O 8-1/4"
1101 7200 8121
1102 7202 8301 STD. FOR MODELS
1103 7120 8601 7-15/16"
7300, (L) 7302Z
1104 7122 8602 7302, (L) 7300ZL 4-5/8"


1101FM 8001 TORK 7300Z 7302ZL
1104FM 8004
AVAILABLE FOR MODELS
7100 8061
2-15/16" 1101 7200, (L,Z,ZL) 1847AL 8007V
7102 1102 7202, (L,Z,ZL) 1847AZL 8061
1103 7120, (L,Z,ZL) 8001 8121
1104 7122, (L,ZL) 8004 8301
1101FM 7220, (L) 8001U 8601
1104FM 7222, (L) 8007 8602
METAL INDOOR NEMA 1 7100 1847A 8007L
#63100 7102 1847AZ
5"
STD. FOR MODELS
7220, (L) 1847AL
7222, (L) 1847AZL
7200L 8007 9-1/4"
7202L 8007L
METAL INDOOR/OUTDOOR
7120L 8007V
NEMA 3 8-3/8 "


1847A 8150
TORK
Model 9006 Suffix O
1848A 8150U AVAILABLE FOR MODELS
1849A W100 W220 TW220L 13-1/8"

3-3/4" W200 W222 TW300L
1847AZ
W202 W220L T920L
W300 W222L T930L
W302 W300L 1847AW
W120 W302L 1847AWL 5-3/16 "

METAL INDOOR NEMA 1
#63016-1 8-1/8"


STD. FOR MODELS
TZ220L W302L
5"
12-1/8 "
TZ300L TW220L NORYL INDOOR/OUTDOOR


W300 TW300L
TORK NEMA 3R
W302 T920L
W300L T930L
Model 9000N Suffix N 9-1/8"


STD. FOR MODELS
4-3/4"
7200Z,(L, ZL) TORK


7202Z,(L, ZL)
7120Z,(L, ZL)
4-1/2"
7122Z, (L, ZL)
METAL INDOOR NEMA 1 AVAILABLE FOR MODELS
#70100 7-5/8 " 1101 7102 7222, (L) 8001U
1102 7200, (L) 1847A 8061
STD. FOR MODELS 1103 7202, (L) 1847AZ 8121
W100 W222 1104 7120, (L) 1847AL 8301
1101FM 7122, (L) 1847AZL 8601
W200 W220L
11-7/8 "
1104FM 7220, (L) 8001 8602
W202 W222L 7100 8004
W120 1847AW TORK



W220 1847AWL

3-1/4 "




METAL INDOOR NEMA 1 NORYL & LEXAN 5"

for W400 Series NEMA 3R
12 -1/2" INDOOR/OUTDOOR TORK 9-1/8"
STD. FOR MODELS Model 9000NC
W400A W400AL
STD. FOR MODELS
W402A W402AL 1101NC
4" 1103NC
4-1/2"
8 -1/4" 1104NC




26
A DIVISION OF NSi INDUSTRIES, LLC
ENCLOSURE & MECHANISM DIMENSIONS
METAL INDOOR NEMA 1 METAL INDOOR/OUTDOOR 5-1/4"

#68229 NEMA 3
STD. FOR
MODELS
4-11/16" Model 9000A Suffix O 8-1/4"
1101 7200 8121
1102 7202 8301 STD. FOR MODELS
1103 7120 8601 7-15/16"
7300, (L) 7302Z
1104 7122 8602 7302, (L) 7300ZL 4-5/8"


1101FM 8001 TORK 7300Z 7302ZL
1104FM 8004
AVAILABLE FOR MODELS
7100 8061
2-15/16" 1101 7200, (L,Z,ZL) 1847AL 8007V
7102 1102 7202, (L,Z,ZL) 1847AZL 8061
1103 7120, (L,Z,ZL) 8001 8121
1104 7122, (L,ZL) 8004 8301
1101FM 7220, (L) 8001U 8601
1104FM 7222, (L) 8007 8602
METAL INDOOR NEMA 1 7100 1847A 8007L
#63100 7102 1847AZ
5"
STD. FOR MODELS
7220, (L) 1847AL
7222, (L) 1847AZL
7200L 8007 9-1/4"
7202L 8007L
METAL INDOOR/OUTDOOR
7120L 8007V
NEMA 3 8-3/8 "


1847A 8150
TORK
Model 9006 Suffix O
1848A 8150U AVAILABLE FOR MODELS
1849A W100 W220 TW220L 13-1/8"

3-3/4" W200 W222 TW300L
1847AZ
W202 W220L T920L
W300 W222L T930L
W302 W300L 1847AW
W120 W302L 1847AWL 5-3/16 "

METAL INDOOR NEMA 1
#63016-1 8-1/8"


STD. FOR MODELS
TZ220L W302L
5"
12-1/8 "
TZ300L TW220L NORYL INDOOR/OUTDOOR


W300 TW300L
TORK NEMA 3R
W302 T920L
W300L T930L
Model 9000N Suffix N 9-1/8"


STD. FOR MODELS
4-3/4"
7200Z,(L, ZL) TORK


7202Z,(L, ZL)
7120Z,(L, ZL)
4-1/2"
7122Z, (L, ZL)
METAL INDOOR NEMA 1 AVAILABLE FOR MODELS
#70100 7-5/8 " 1101 7102 7222, (L) 8001U
1102 7200, (L) 1847A 8061
STD. FOR MODELS 1103 7202, (L) 1847AZ 8121
W100 W222 1104 7120, (L) 1847AL 8301
1101FM 7122, (L) 1847AZL 8601
W200 W220L
11-7/8 "
1104FM 7220, (L) 8001 8602
W202 W222L 7100 8004
W120 1847AW TORK



W220 1847AWL

3-1/4 "




METAL INDOOR NEMA 1 NORYL & LEXAN 5"

for W400 Series NEMA 3R
12 -1/2" INDOOR/OUTDOOR TORK 9-1/8"
STD. FOR MODELS Model 9000NC
W400A W400AL
STD. FOR MODELS
W402A W402AL 1101NC
4" 1103NC
4-1/2"
8 -1/4" 1104NC




26
A DIVISION OF NSi INDUSTRIES, LLC
ENCLOSURE & MECHANISM DIMENSIONS
METAL INDOOR NEMA 1 METAL INDOOR/OUTDOOR 5-1/4"

#68229 NEMA 3
STD. FOR
MODELS
4-11/16" Model 9000A Suffix O 8-1/4"
1101 7200 8121
1102 7202 8301 STD. FOR MODELS
1103 7120 8601 7-15/16"
7300, (L) 7302Z
1104 7122 8602 7302, (L) 7300ZL 4-5/8"


1101FM 8001 TORK 7300Z 7302ZL
1104FM 8004
AVAILABLE FOR MODELS
7100 8061
2-15/16" 1101 7200, (L,Z,ZL) 1847AL 8007V
7102 1102 7202, (L,Z,ZL) 1847AZL 8061
1103 7120, (L,Z,ZL) 8001 8121
1104 7122, (L,ZL) 8004 8301
1101FM 7220, (L) 8001U 8601
1104FM 7222, (L) 8007 8602
METAL INDOOR NEMA 1 7100 1847A 8007L
#63100 7102 1847AZ
5"
STD. FOR MODELS
7220, (L) 1847AL
7222, (L) 1847AZL
7200L 8007 9-1/4"
7202L 8007L
METAL INDOOR/OUTDOOR
7120L 8007V
NEMA 3 8-3/8 "


1847A 8150
TORK
Model 9006 Suffix O
1848A 8150U AVAILABLE FOR MODELS
1849A W100 W220 TW220L 13-1/8"

3-3/4" W200 W222 TW300L
1847AZ
W202 W220L T920L
W300 W222L T930L
W302 W300L 1847AW
W120 W302L 1847AWL 5-3/16 "

METAL INDOOR NEMA 1
#63016-1 8-1/8"


STD. FOR MODELS
TZ220L W302L
5"
12-1/8 "
TZ300L TW220L NORYL INDOOR/OUTDOOR


W300 TW300L
TORK NEMA 3R
W302 T920L
W300L T930L
Model 9000N Suffix N 9-1/8"


STD. FOR MODELS
4-3/4"
7200Z,(L, ZL) TORK


7202Z,(L, ZL)
7120Z,(L, ZL)
4-1/2"
7122Z, (L, ZL)
METAL INDOOR NEMA 1 AVAILABLE FOR MODELS
#70100 7-5/8 " 1101 7102 7222, (L) 8001U
1102 7200, (L) 1847A 8061
STD. FOR MODELS 1103 7202, (L) 1847AZ 8121
W100 W222 1104 7120, (L) 1847AL 8301
1101FM 7122, (L) 1847AZL 8601
W200 W220L
11-7/8 "
1104FM 7220, (L) 8001 8602
W202 W222L 7100 8004
W120 1847AW TORK



W220 1847AWL

3-1/4 "




METAL INDOOR NEMA 1 NORYL & LEXAN 5"

for W400 Series NEMA 3R
12 -1/2" INDOOR/OUTDOOR TORK 9-1/8"
STD. FOR MODELS Model 9000NC
W400A W400AL
STD. FOR MODELS
W402A W402AL 1101NC
4" 1103NC
4-1/2"
8 -1/4" 1104NC




26
A DIVISION OF NSi INDUSTRIES, LLC
METAL DUPLEX METAL FLUSH NEMA 1
NEMA 3 10-3/8" Model 9001 Suffix FL1
INDOOR/OUTDOOR Model 9002 Suffix FL2*
Model 9004L 8"
11-9/32 "
Suffix DUOL AVAILABLE FOR MODELS
1101 7200, (L,Z,ZL)
STD. FOR MODELS
1102 7202, (L,Z,ZL)
1101D 1101DF 7120, (L,Z,ZL)
1103 11" 9-1/8"
1114D 1114DF 1104 7122, (ZL)
4-1/4"
1104D 1104DF 1101FM 7220, (L)
AVAIL. FOR MODELS 1104FM 7222, (L)
6-1/8"
1101 7100 7100 8000 Series
4-3/16"
1102 7102 7102
1103 7200, (L,Z,ZL)
1104 7202, (L,Z,ZL) *Model 9002 (FL2) Depth is 4-9/16
1101FM 7120, (L,Z,ZL) For Models 7300 and 7302
1104FM 7122, (ZL)
7220, (L)
7222, (L)
MODELS
4-9/16"
8601
8602
MODELS:
1101 1847A 4-9/16" 3-1/2" 8301 5-3/4"

1102 1848A 8121
1103 8061
1849A 3-1/2"
1104
1847AZ MECHANISM WITH MOUNTING
1101FM 7-1/2"
1848AZ ONLY BRACKET
1104FM #65447
1849AZ
7100
7102 1847AL 7-5/8"
3-1/2"

7200, (L,Z,ZL) 1848AL MODELS
2-1/2"

7202, (L,Z,ZL) 1849AL MECHANISM WITH MOUNTING W100
ONLY BRACKET W200
11-1/2"

7120, (L,Z,ZL) 1847AZL #65447
W202
7122, (ZL) 1848AZL W120
7220, (L)
1849AZL W220 MECHANISM WITH MOUNTING
7222, (L) ONLY BRACKET
W222
#64039
4-1/4"
4-9/16"

MODELS: 7-5/8"
7300, (L,Z,ZL) 3-5/8 "

7302, (L,Z,ZL)
7-1/2" MODELS 3-1/16"

W300
11-1/2"
W302



MECHANISM WITH MOUNTING
ONLY BRACKET MECHANISM WITH MOUNTING
#64040 ONLY BRACKET
#62153-1

MODELS 4-9/16"
7-3/4" 3-1/2"

8001 MODELS
8004 1847AWL
5-5/8" 11-1/2"
8007 1848AWL

8008 1849AWL
3-1/2"


MECHANISM WITH MOUNTING MECHANISM WITH MOUNTING
ONLY BRACKET ONLY BRACKET
#65447 #65447


27
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC




Powered by Venture
Open Source ERP Software