B BRACKET FOR WALL MOUNTING OF CONDUIT MODELS
NSI / Tork Electrical, Lighting Pool & Spa Products and Replacement Parts
2100 SERIES
SPECIFICATION GRADE
12 CONDUIT MOUNTING
IN DIE CAST ZINC
APPLICATIONS
Parking Lot Lighting Control
Building Perimeter Lighting Control
Outdoor Sign Lights
FEATURES
Heavy Duty die cast zinc housing and base.
Gasketed for maximum weather protection
Delay of up to two minutes prevents false
switching due to light from vehicles or
lightning, etc.
SPECIFICATIONS MOUNTING
Turn ON/Turn OFF: Turn ON is 1 to 5fc, Turn OFF is 3 to 15fc, BRACKET
without the slide in position.ON/OFF adjustment is easily made
by moving a light level selector. No tools required. 2"
DIMENSIONS
1-7/8" 3-1/4"
2" 1-7/8"
1-7/8" 3-1/4"
Cell: Cadmium sulphide, epoxy coated, 1 diameter. 2" 3-1/4"
Contacts: Remain closed between dusk and dawn. (The unit fails
in the ON position). 3" 3" 4-1/2"
4-1/2"
3"
Lead Wires: Three color coded, minimum 6 wire 4-1/2"
leads, #16AWG, rated for 105C.
Power Consumption: Averages under 1 watt. 3/4" B-BRACKET FOR
Temperature Range: -40 to +140F (-40 to +60C) 3/4"
3/4" WALL MOUNTING OFFOR
B-BRACKET ALL
1/2" CONDUIT B-BRACKET FOR
FITTING 1/2 CONDUIT MODELSOF ALL
WALL MOUNTING OF ALL
1/2" CONDUIT
1/2" CONDUIT WALL MOUNTING
PART #73866
1/2 CONDUIT MODELS
FITTING
FITTING 1/2 CONDUIT MODELS
PART #73866
PART #73866
CATALOG UPC VOLTAGE RATING
NO CODE 50-60HZ SWITCH TUNGSTEN BALLAST
2101 60012 120 SPST 2000W 1800VA
2104 60013 208-277 SPST 2000W 1800VA
2105* 60030 120 SPST 3000W 3000VA
2107 60031 120/277 SPST 2000W 1800VA
73866 MOUNTING BRACKET
*MODEL 2105 HAS A POLYCARBONATE ENCLOSURE, 12 CELL, 1 YEAR WARRANTY. NOT UL OR CSA.
WIRING DIAGRAMS
SPECIFICATION WRITERS GUIDE
Photocontrol enclosure shall be constructed of die cast zinc, gasketed for weather protection. Cell shall be cadmium sulphide, epoxy coated, one inch diameter. Unit shall
have a slide for earlier or later turn ON. Contacts shall be normally closed and fail in the ON position. Photocontrol must withstand temperatures of -40to +140F. Unit to
be provided with three color coded, minimum six inch wire leads, #16 AWG, rated for 105C. Photocontrol shall have a xed base for mounting through 78 inch opening or
1
2 inch K.O. Furnish and install TORK Model 2101, 120VAC, (Model 2104 208-277VAC), (Model 2107, 120/277VAC)
1
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
2100 SERIES
SPECIFICATION GRADE
12 CONDUIT MOUNTING
IN DIE CAST ZINC
APPLICATIONS
Parking Lot Lighting Control
Building Perimeter Lighting Control
Outdoor Sign Lights
FEATURES
Heavy Duty die cast zinc housing and base.
Gasketed for maximum weather protection
Delay of up to two minutes prevents false
switching due to light from vehicles or
lightning, etc.
SPECIFICATIONS MOUNTING
Turn ON/Turn OFF: Turn ON is 1 to 5fc, Turn OFF is 3 to 15fc, BRACKET
without the slide in position.ON/OFF adjustment is easily made
by moving a light level selector. No tools required. 2"
DIMENSIONS
1-7/8" 3-1/4"
2" 1-7/8"
1-7/8" 3-1/4"
Cell: Cadmium sulphide, epoxy coated, 1 diameter. 2" 3-1/4"
Contacts: Remain closed between dusk and dawn. (The unit fails
in the ON position). 3" 3" 4-1/2"
4-1/2"
3"
Lead Wires: Three color coded, minimum 6 wire 4-1/2"
leads, #16AWG, rated for 105C.
Power Consumption: Averages under 1 watt. 3/4" B-BRACKET FOR
Temperature Range: -40 to +140F (-40 to +60C) 3/4"
3/4" WALL MOUNTING OFFOR
B-BRACKET ALL
1/2" CONDUIT B-BRACKET FOR
FITTING 1/2 CONDUIT MODELSOF ALL
WALL MOUNTING OF ALL
1/2" CONDUIT
1/2" CONDUIT WALL MOUNTING
PART #73866
1/2 CONDUIT MODELS
FITTING
FITTING 1/2 CONDUIT MODELS
PART #73866
PART #73866
CATALOG UPC VOLTAGE RATING
NO CODE 50-60HZ SWITCH TUNGSTEN BALLAST
2101 60012 120 SPST 2000W 1800VA
2104 60013 208-277 SPST 2000W 1800VA
2105* 60030 120 SPST 3000W 3000VA
2107 60031 120/277 SPST 2000W 1800VA
73866 MOUNTING BRACKET
*MODEL 2105 HAS A POLYCARBONATE ENCLOSURE, 12 CELL, 1 YEAR WARRANTY. NOT UL OR CSA.
WIRING DIAGRAMS
SPECIFICATION WRITERS GUIDE
Photocontrol enclosure shall be constructed of die cast zinc, gasketed for weather protection. Cell shall be cadmium sulphide, epoxy coated, one inch diameter. Unit shall
have a slide for earlier or later turn ON. Contacts shall be normally closed and fail in the ON position. Photocontrol must withstand temperatures of -40to +140F. Unit to
be provided with three color coded, minimum six inch wire leads, #16 AWG, rated for 105C. Photocontrol shall have a xed base for mounting through 78 inch opening or
1
2 inch K.O. Furnish and install TORK Model 2101, 120VAC, (Model 2104 208-277VAC), (Model 2107, 120/277VAC)
1
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
2100 SERIES
SPECIFICATION GRADE
12 CONDUIT MOUNTING
IN DIE CAST ZINC
APPLICATIONS
Parking Lot Lighting Control
Building Perimeter Lighting Control
Outdoor Sign Lights
FEATURES
Heavy Duty die cast zinc housing and base.
Gasketed for maximum weather protection
Delay of up to two minutes prevents false
switching due to light from vehicles or
lightning, etc.
SPECIFICATIONS MOUNTING
Turn ON/Turn OFF: Turn ON is 1 to 5fc, Turn OFF is 3 to 15fc, BRACKET
without the slide in position.ON/OFF adjustment is easily made
by moving a light level selector. No tools required. 2"
DIMENSIONS
1-7/8" 3-1/4"
2" 1-7/8"
1-7/8" 3-1/4"
Cell: Cadmium sulphide, epoxy coated, 1 diameter. 2" 3-1/4"
Contacts: Remain closed between dusk and dawn. (The unit fails
in the ON position). 3" 3" 4-1/2"
4-1/2"
3"
Lead Wires: Three color coded, minimum 6 wire 4-1/2"
leads, #16AWG, rated for 105C.
Power Consumption: Averages under 1 watt. 3/4" B-BRACKET FOR
Temperature Range: -40 to +140F (-40 to +60C) 3/4"
3/4" WALL MOUNTING OFFOR
B-BRACKET ALL
1/2" CONDUIT B-BRACKET FOR
FITTING 1/2 CONDUIT MODELSOF ALL
WALL MOUNTING OF ALL
1/2" CONDUIT
1/2" CONDUIT WALL MOUNTING
PART #73866
1/2 CONDUIT MODELS
FITTING
FITTING 1/2 CONDUIT MODELS
PART #73866
PART #73866
CATALOG UPC VOLTAGE RATING
NO CODE 50-60HZ SWITCH TUNGSTEN BALLAST
2101 60012 120 SPST 2000W 1800VA
2104 60013 208-277 SPST 2000W 1800VA
2105* 60030 120 SPST 3000W 3000VA
2107 60031 120/277 SPST 2000W 1800VA
73866 MOUNTING BRACKET
*MODEL 2105 HAS A POLYCARBONATE ENCLOSURE, 12 CELL, 1 YEAR WARRANTY. NOT UL OR CSA.
WIRING DIAGRAMS
SPECIFICATION WRITERS GUIDE
Photocontrol enclosure shall be constructed of die cast zinc, gasketed for weather protection. Cell shall be cadmium sulphide, epoxy coated, one inch diameter. Unit shall
have a slide for earlier or later turn ON. Contacts shall be normally closed and fail in the ON position. Photocontrol must withstand temperatures of -40to +140F. Unit to
be provided with three color coded, minimum six inch wire leads, #16 AWG, rated for 105C. Photocontrol shall have a xed base for mounting through 78 inch opening or
1
2 inch K.O. Furnish and install TORK Model 2101, 120VAC, (Model 2104 208-277VAC), (Model 2107, 120/277VAC)
1
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
2100 SERIES
SPECIFICATION GRADE
12 CONDUIT MOUNTING
IN DIE CAST ZINC
APPLICATIONS
Parking Lot Lighting Control
Building Perimeter Lighting Control
Outdoor Sign Lights
FEATURES
Heavy Duty die cast zinc housing and base.
Gasketed for maximum weather protection
Delay of up to two minutes prevents false
switching due to light from vehicles or
lightning, etc.
SPECIFICATIONS MOUNTING
Turn ON/Turn OFF: Turn ON is 1 to 5fc, Turn OFF is 3 to 15fc, BRACKET
without the slide in position.ON/OFF adjustment is easily made
by moving a light level selector. No tools required. 2"
DIMENSIONS
1-7/8" 3-1/4"
2" 1-7/8"
1-7/8" 3-1/4"
Cell: Cadmium sulphide, epoxy coated, 1 diameter. 2" 3-1/4"
Contacts: Remain closed between dusk and dawn. (The unit fails
in the ON position). 3" 3" 4-1/2"
4-1/2"
3"
Lead Wires: Three color coded, minimum 6 wire 4-1/2"
leads, #16AWG, rated for 105C.
Power Consumption: Averages under 1 watt. 3/4" B-BRACKET FOR
Temperature Range: -40 to +140F (-40 to +60C) 3/4"
3/4" WALL MOUNTING OFFOR
B-BRACKET ALL
1/2" CONDUIT B-BRACKET FOR
FITTING 1/2 CONDUIT MODELSOF ALL
WALL MOUNTING OF ALL
1/2" CONDUIT
1/2" CONDUIT WALL MOUNTING
PART #73866
1/2 CONDUIT MODELS
FITTING
FITTING 1/2 CONDUIT MODELS
PART #73866
PART #73866
CATALOG UPC VOLTAGE RATING
NO CODE 50-60HZ SWITCH TUNGSTEN BALLAST
2101 60012 120 SPST 2000W 1800VA
2104 60013 208-277 SPST 2000W 1800VA
2105* 60030 120 SPST 3000W 3000VA
2107 60031 120/277 SPST 2000W 1800VA
73866 MOUNTING BRACKET
*MODEL 2105 HAS A POLYCARBONATE ENCLOSURE, 12 CELL, 1 YEAR WARRANTY. NOT UL OR CSA.
WIRING DIAGRAMS
SPECIFICATION WRITERS GUIDE
Photocontrol enclosure shall be constructed of die cast zinc, gasketed for weather protection. Cell shall be cadmium sulphide, epoxy coated, one inch diameter. Unit shall
have a slide for earlier or later turn ON. Contacts shall be normally closed and fail in the ON position. Photocontrol must withstand temperatures of -40to +140F. Unit to
be provided with three color coded, minimum six inch wire leads, #16 AWG, rated for 105C. Photocontrol shall have a xed base for mounting through 78 inch opening or
1
2 inch K.O. Furnish and install TORK Model 2101, 120VAC, (Model 2104 208-277VAC), (Model 2107, 120/277VAC)
1
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
2000 SERIES
12 CONDUIT MOUNTING FIXED
POSITION, LEXAN HOUSING WITH
WEATHERPROOF SEALANT
APPLICATIONS SPECIFICATIONS
Flood Lamp Control TURN ON/TURN OFF:
Patio Lamp Control Turn ON is 1 to 5fc
Decorative Lighting Control Turn OFF is 3 to 15fc, without the slide in position.
ON/OFF adjustment is easily made by moving a light
FEATURES level selector. No tools required.
All Lexan enclosure is impact and vandal resistant CELL: Cadmium sulphide, epoxy coated, 12 diameter.
Translucent Lexan Dome prolongs cell life by further CONTACTS: Remain closed between dusk and dawn.
screening out ultraviolet rays. Dome and base are (The unit fails in the ON position).
ultrasonically welded for maximum strength. LEAD WIRES: Three color coded, minimum 6
Delay of up to two minutes prevents wire leads, #16AWG, rated for 105C.
false switching due to light from vehicles or lightning, etc. POWER CONSUMPTION: Averages under 1watt.
TEMPERATURE RANGE: -40 to +140F (-40 to +60C)
CATALOG UPC VOLTAGE RATING
NO CODE 50-60HZ SWITCH TUNGSTEN BALLAST
2000 60017 120 SPST 2000W 1800VA
2000C 60317 SAME AS ABOVE, IN CLAMSHELL PACKAGE
2000-2 60018 208-277 SPST 2000W 1800VA
2000-7* 62013 120/277 SPST 2000W 1800VA
73866 MOUNTING BRACKET
*MODEL 2000-7 HAS A CADMIUM SULPHIDE, 1 EPOXY CELL.
DIMENSIONS WIRING DIAGRAMS
1-5/8"
Move Slide for Earlier
or Later Turn ON
2-3/4"
Black Line Red Lamp
MOUNT
White Neutral
nut and
neoprene
AT ANY
3/4" washer
(to be
provided
ANGLE
by the
MOUNTING installer)
BRACKET 1/2" nipple
junction box
8" 3-1/4" Move Slide for Earlier
/8" 3-1/4" or Later Turn ON
4-1/2"
4-1/2"
(Black) Line (Red) Lamp
L1
240V (White)
L2
For 277VAC:
B-BRACKET FOR
WALL MOUNTING OFFOR
B-BRACKET ALL L1 - Line
1/2 CONDUIT MODELSOF ALL
WALL MOUNTING L2 - Neutral
PART #73866
1/2 CONDUIT MODELS
PART #73866
SPECIFICATION WRITERS GUIDE
Photocontrol enclosure shall be constructed of Lexan material. Dome shall be UV stabilized to screen out ultraviolet rays. Dome and base shall
be ultrasonically welded. Cell shall be cadmium sulphide, epoxy coated, 12 inch diameter. Unit shall have a slide for earlier or later turn ON.
Contacts shall be normally closed and fail in the ON position. Photocontrol must withstand temperatures of -40to +140F. Unit to be provided
with three color coded, minimum six inch wire leads, #16 AWG, rated for 105C. Photocontrol shall have a xed base for mounting through 78
inch opening or 12 inch K.O. Furnish and install TORK Model 2000, 120VAC, (Model 2002, 208-277VAC), (Model 2007, 120/277VAC)
2
A DIVISION OF NSi INDUSTRIES, LLC
2000 SERIES
12 CONDUIT MOUNTING FIXED
POSITION, LEXAN HOUSING WITH
WEATHERPROOF SEALANT
APPLICATIONS SPECIFICATIONS
Flood Lamp Control TURN ON/TURN OFF:
Patio Lamp Control Turn ON is 1 to 5fc
Decorative Lighting Control Turn OFF is 3 to 15fc, without the slide in position.
ON/OFF adjustment is easily made by moving a light
FEATURES level selector. No tools required.
All Lexan enclosure is impact and vandal resistant CELL: Cadmium sulphide, epoxy coated, 12 diameter.
Translucent Lexan Dome prolongs cell life by further CONTACTS: Remain closed between dusk and dawn.
screening out ultraviolet rays. Dome and base are (The unit fails in the ON position).
ultrasonically welded for maximum strength. LEAD WIRES: Three color coded, minimum 6
Delay of up to two minutes prevents wire leads, #16AWG, rated for 105C.
false switching due to light from vehicles or lightning, etc. POWER CONSUMPTION: Averages under 1watt.
TEMPERATURE RANGE: -40 to +140F (-40 to +60C)
CATALOG UPC VOLTAGE RATING
NO CODE 50-60HZ SWITCH TUNGSTEN BALLAST
2000 60017 120 SPST 2000W 1800VA
2000C 60317 SAME AS ABOVE, IN CLAMSHELL PACKAGE
2000-2 60018 208-277 SPST 2000W 1800VA
2000-7* 62013 120/277 SPST 2000W 1800VA
73866 MOUNTING BRACKET
*MODEL 2000-7 HAS A CADMIUM SULPHIDE, 1 EPOXY CELL.
DIMENSIONS WIRING DIAGRAMS
1-5/8"
Move Slide for Earlier
or Later Turn ON
2-3/4"
Black Line Red Lamp
MOUNT
White Neutral
nut and
neoprene
AT ANY
3/4" washer
(to be
provided
ANGLE
by the
MOUNTING installer)
BRACKET 1/2" nipple
junction box
8" 3-1/4" Move Slide for Earlier
/8" 3-1/4" or Later Turn ON
4-1/2"
4-1/2"
(Black) Line (Red) Lamp
L1
240V (White)
L2
For 277VAC:
B-BRACKET FOR
WALL MOUNTING OFFOR
B-BRACKET ALL L1 - Line
1/2 CONDUIT MODELSOF ALL
WALL MOUNTING L2 - Neutral
PART #73866
1/2 CONDUIT MODELS
PART #73866
SPECIFICATION WRITERS GUIDE
Photocontrol enclosure shall be constructed of Lexan material. Dome shall be UV stabilized to screen out ultraviolet rays. Dome and base shall
be ultrasonically welded. Cell shall be cadmium sulphide, epoxy coated, 12 inch diameter. Unit shall have a slide for earlier or later turn ON.
Contacts shall be normally closed and fail in the ON position. Photocontrol must withstand temperatures of -40to +140F. Unit to be provided
with three color coded, minimum six inch wire leads, #16 AWG, rated for 105C. Photocontrol shall have a xed base for mounting through 78
inch opening or 12 inch K.O. Furnish and install TORK Model 2000, 120VAC, (Model 2002, 208-277VAC), (Model 2007, 120/277VAC)
2
A DIVISION OF NSi INDUSTRIES, LLC
2000 SERIES
12 CONDUIT MOUNTING FIXED
POSITION, LEXAN HOUSING WITH
WEATHERPROOF SEALANT
APPLICATIONS SPECIFICATIONS
Flood Lamp Control TURN ON/TURN OFF:
Patio Lamp Control Turn ON is 1 to 5fc
Decorative Lighting Control Turn OFF is 3 to 15fc, without the slide in position.
ON/OFF adjustment is easily made by moving a light
FEATURES level selector. No tools required.
All Lexan enclosure is impact and vandal resistant CELL: Cadmium sulphide, epoxy coated, 12 diameter.
Translucent Lexan Dome prolongs cell life by further CONTACTS: Remain closed between dusk and dawn.
screening out ultraviolet rays. Dome and base are (The unit fails in the ON position).
ultrasonically welded for maximum strength. LEAD WIRES: Three color coded, minimum 6
Delay of up to two minutes prevents wire leads, #16AWG, rated for 105C.
false switching due to light from vehicles or lightning, etc. POWER CONSUMPTION: Averages under 1watt.
TEMPERATURE RANGE: -40 to +140F (-40 to +60C)
CATALOG UPC VOLTAGE RATING
NO CODE 50-60HZ SWITCH TUNGSTEN BALLAST
2000 60017 120 SPST 2000W 1800VA
2000C 60317 SAME AS ABOVE, IN CLAMSHELL PACKAGE
2000-2 60018 208-277 SPST 2000W 1800VA
2000-7* 62013 120/277 SPST 2000W 1800VA
73866 MOUNTING BRACKET
*MODEL 2000-7 HAS A CADMIUM SULPHIDE, 1 EPOXY CELL.
DIMENSIONS WIRING DIAGRAMS
1-5/8"
Move Slide for Earlier
or Later Turn ON
2-3/4"
Black Line Red Lamp
MOUNT
White Neutral
nut and
neoprene
AT ANY
3/4" washer
(to be
provided
ANGLE
by the
MOUNTING installer)
BRACKET 1/2" nipple
junction box
8" 3-1/4" Move Slide for Earlier
/8" 3-1/4" or Later Turn ON
4-1/2"
4-1/2"
(Black) Line (Red) Lamp
L1
240V (White)
L2
For 277VAC:
B-BRACKET FOR
WALL MOUNTING OFFOR
B-BRACKET ALL L1 - Line
1/2 CONDUIT MODELSOF ALL
WALL MOUNTING L2 - Neutral
PART #73866
1/2 CONDUIT MODELS
PART #73866
SPECIFICATION WRITERS GUIDE
Photocontrol enclosure shall be constructed of Lexan material. Dome shall be UV stabilized to screen out ultraviolet rays. Dome and base shall
be ultrasonically welded. Cell shall be cadmium sulphide, epoxy coated, 12 inch diameter. Unit shall have a slide for earlier or later turn ON.
Contacts shall be normally closed and fail in the ON position. Photocontrol must withstand temperatures of -40to +140F. Unit to be provided
with three color coded, minimum six inch wire leads, #16 AWG, rated for 105C. Photocontrol shall have a xed base for mounting through 78
inch opening or 12 inch K.O. Furnish and install TORK Model 2000, 120VAC, (Model 2002, 208-277VAC), (Model 2007, 120/277VAC)
2
A DIVISION OF NSi INDUSTRIES, LLC
2001 SERIES
1
2 CONDUIT MOUNTING, 180 SWIVEL, LEXAN HOUSING
APPLICATIONS SPECIFICATIONS
TURN ON/TURN OFF:
Flood Lamp Control
Turn ON is 1 to 5fc
Patio Lamp Control Turn OFF is 3 to 15fc, without the slide in position.
Decorative Lighting Control ON/OFF adjustment is easily made by moving a light level
selector. No tools required.
FEATURES CELL: Cadmium sulphide, epoxy coated, 12 diameter.
All Lexan enclosure is impact and vandal resistant CONTACTS: Remain closed between dusk and dawn. (The unit fails
in the ON position).
Translucent Lexan Dome prolongs cell life by further
LEAD WIRES: Three color coded, minimum 6 wire
screening out ultraviolet rays. Dome and base are
leads, #16AWG, rated for 105C.
ultrasonically welded for maximum strength.
POWER CONSUMPTION: Averages under 1
Delay of up to two minutes prevents watt.
false switching due to light TEMPERATURE RANGE: -40 to +140F (-
from vehicles or lightning, etc. 40 to +60C)
180
SWIVEL
CATALOG UPC VOLTAGE RATING
NO CODE 50-60HZ SWITCH TUNGSTEN BALLAST
2001 60015 120 SPST 2000W 1800VA
2001C 60315 SAME AS ABOVE, IN CLAMSHELL PACKAGE
2002 60016 208-277 SPST 2000W 1800VA
73866 MOUNTING BRACKET
DIMENSIONS MOUNTING WIRING DIAGRAMS
BRACKET
1-5/8"
Move Slide for Earlier
2" 1-7/8" 3-1/4" or Later Turn ON
2" 1-7/8" 3-1/4"
Black Line Red Lamp
3" 3" 3-3/4"
4-1/2"
4-1/2"
White Neutral
3/4" B-BRACKET FOR
3/4" WALL MOUNTING OFFOR
B-BRACKET ALL
1/2" CONDUIT
FITTING 3/4" 1/2 CONDUIT MODELSOF ALL
WALL MOUNTING
1/2" CONDUIT
PART #73866
1/2 CONDUIT MODELS
FITTING
PART #73866 Move Slide for Earlier
or Later Turn ON
(Black) Line (Red) Lamp For 277VAC:
L1
240V (White)
L1 - Line
L2 L2 - Neutral
SPECIFICATION WRITERS GUIDE
Photocontrol enclosure shall be constructed of Lexan material. Dome shall be UV stabilized to screen out ultraviolet rays. Dome and base shall be ultrasonically welded.
Cell shall be cadmium sulphide, epoxy coated, 12 inch diameter. Unit shall have a slide for earlier or later turn ON. Contacts shall be normally closed and fail in the ON
position. Photocontrol must withstand temperatures of -40to +140F. Unit to be provided with three color coded, minimum six inch wire leads, #16 AWG, rated for
105C. Photocontrol shall have a 180 swivel base for mounting through 78 inch opening or 12 inch K.O. Furnish and install TORK Model 2001, 120VAC, (Model 2002, 208-
277VAC).
Lexan is a registered trademark of the General Electric Co. 3
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
2001 SERIES
1
2 CONDUIT MOUNTING, 180 SWIVEL, LEXAN HOUSING
APPLICATIONS SPECIFICATIONS
TURN ON/TURN OFF:
Flood Lamp Control
Turn ON is 1 to 5fc
Patio Lamp Control Turn OFF is 3 to 15fc, without the slide in position.
Decorative Lighting Control ON/OFF adjustment is easily made by moving a light level
selector. No tools required.
FEATURES CELL: Cadmium sulphide, epoxy coated, 12 diameter.
All Lexan enclosure is impact and vandal resistant CONTACTS: Remain closed between dusk and dawn. (The unit fails
in the ON position).
Translucent Lexan Dome prolongs cell life by further
LEAD WIRES: Three color coded, minimum 6 wire
screening out ultraviolet rays. Dome and base are
leads, #16AWG, rated for 105C.
ultrasonically welded for maximum strength.
POWER CONSUMPTION: Averages under 1
Delay of up to two minutes prevents watt.
false switching due to light TEMPERATURE RANGE: -40 to +140F (-
from vehicles or lightning, etc. 40 to +60C)
180
SWIVEL
CATALOG UPC VOLTAGE RATING
NO CODE 50-60HZ SWITCH TUNGSTEN BALLAST
2001 60015 120 SPST 2000W 1800VA
2001C 60315 SAME AS ABOVE, IN CLAMSHELL PACKAGE
2002 60016 208-277 SPST 2000W 1800VA
73866 MOUNTING BRACKET
DIMENSIONS MOUNTING WIRING DIAGRAMS
BRACKET
1-5/8"
Move Slide for Earlier
2" 1-7/8" 3-1/4" or Later Turn ON
2" 1-7/8" 3-1/4"
Black Line Red Lamp
3" 3" 3-3/4"
4-1/2"
4-1/2"
White Neutral
3/4" B-BRACKET FOR
3/4" WALL MOUNTING OFFOR
B-BRACKET ALL
1/2" CONDUIT
FITTING 3/4" 1/2 CONDUIT MODELSOF ALL
WALL MOUNTING
1/2" CONDUIT
PART #73866
1/2 CONDUIT MODELS
FITTING
PART #73866 Move Slide for Earlier
or Later Turn ON
(Black) Line (Red) Lamp For 277VAC:
L1
240V (White)
L1 - Line
L2 L2 - Neutral
SPECIFICATION WRITERS GUIDE
Photocontrol enclosure shall be constructed of Lexan material. Dome shall be UV stabilized to screen out ultraviolet rays. Dome and base shall be ultrasonically welded.
Cell shall be cadmium sulphide, epoxy coated, 12 inch diameter. Unit shall have a slide for earlier or later turn ON. Contacts shall be normally closed and fail in the ON
position. Photocontrol must withstand temperatures of -40to +140F. Unit to be provided with three color coded, minimum six inch wire leads, #16 AWG, rated for
105C. Photocontrol shall have a 180 swivel base for mounting through 78 inch opening or 12 inch K.O. Furnish and install TORK Model 2001, 120VAC, (Model 2002, 208-
277VAC).
Lexan is a registered trademark of the General Electric Co. 3
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
2001 SERIES
1
2 CONDUIT MOUNTING, 180 SWIVEL, LEXAN HOUSING
APPLICATIONS SPECIFICATIONS
TURN ON/TURN OFF:
Flood Lamp Control
Turn ON is 1 to 5fc
Patio Lamp Control Turn OFF is 3 to 15fc, without the slide in position.
Decorative Lighting Control ON/OFF adjustment is easily made by moving a light level
selector. No tools required.
FEATURES CELL: Cadmium sulphide, epoxy coated, 12 diameter.
All Lexan enclosure is impact and vandal resistant CONTACTS: Remain closed between dusk and dawn. (The unit fails
in the ON position).
Translucent Lexan Dome prolongs cell life by further
LEAD WIRES: Three color coded, minimum 6 wire
screening out ultraviolet rays. Dome and base are
leads, #16AWG, rated for 105C.
ultrasonically welded for maximum strength.
POWER CONSUMPTION: Averages under 1
Delay of up to two minutes prevents watt.
false switching due to light TEMPERATURE RANGE: -40 to +140F (-
from vehicles or lightning, etc. 40 to +60C)
180
SWIVEL
CATALOG UPC VOLTAGE RATING
NO CODE 50-60HZ SWITCH TUNGSTEN BALLAST
2001 60015 120 SPST 2000W 1800VA
2001C 60315 SAME AS ABOVE, IN CLAMSHELL PACKAGE
2002 60016 208-277 SPST 2000W 1800VA
73866 MOUNTING BRACKET
DIMENSIONS MOUNTING WIRING DIAGRAMS
BRACKET
1-5/8"
Move Slide for Earlier
2" 1-7/8" 3-1/4" or Later Turn ON
2" 1-7/8" 3-1/4"
Black Line Red Lamp
3" 3" 3-3/4"
4-1/2"
4-1/2"
White Neutral
3/4" B-BRACKET FOR
3/4" WALL MOUNTING OFFOR
B-BRACKET ALL
1/2" CONDUIT
FITTING 3/4" 1/2 CONDUIT MODELSOF ALL
WALL MOUNTING
1/2" CONDUIT
PART #73866
1/2 CONDUIT MODELS
FITTING
PART #73866 Move Slide for Earlier
or Later Turn ON
(Black) Line (Red) Lamp For 277VAC:
L1
240V (White)
L1 - Line
L2 L2 - Neutral
SPECIFICATION WRITERS GUIDE
Photocontrol enclosure shall be constructed of Lexan material. Dome shall be UV stabilized to screen out ultraviolet rays. Dome and base shall be ultrasonically welded.
Cell shall be cadmium sulphide, epoxy coated, 12 inch diameter. Unit shall have a slide for earlier or later turn ON. Contacts shall be normally closed and fail in the ON
position. Photocontrol must withstand temperatures of -40to +140F. Unit to be provided with three color coded, minimum six inch wire leads, #16 AWG, rated for
105C. Photocontrol shall have a 180 swivel base for mounting through 78 inch opening or 12 inch K.O. Furnish and install TORK Model 2001, 120VAC, (Model 2002, 208-
277VAC).
Lexan is a registered trademark of the General Electric Co. 3
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
2020 SERIES
1
2 CONDUIT MOUNTING, 180 SWIVEL, LEXAN HOUSING
180
APPLICATIONS
SWIVEL
Flood & Patio Lamp Control
Decorative Lighting Control
PENCIL
Ideal for applications where it is essential to aim the
photocell in an exact direction to sense natural light
but avoid articial light.
FEATURES
All Lexan enclosure is impact and vandal resistant,
cover and base are ultrasonically welded for
maximum strength.
Delay of up to two minutes prevents false switching
due to light from vehicles or lightning, etc.
DIMENSIONS MOUNTING
SPECIFICATIONS BRACKET
TURN ON/TURN OFF: Turn ON is 1 to 5fc 1-1/4"D
Turn OFF is 3 to 15fc
2" 1-7/8" 3-1/4"
CELL: Cadmium sulphide, epoxy coated, 12 diameter. 2" 1-7/8" 3-1/4"
CONTACTS: Normally closed.
(The unit fails in the ON position).
3" 3" 4-1/8"
LEAD WIRES: Three color coded, minimum 6 wire leads, 4-1/2"
4-1/2"
MAX.
#16AWG, rated for 105C.
POWER CONSUMPTION: Averages under 1 watt.
TEMPERATURE RANGE: -40 to +140F 3/4" B-BRACKET FOR
(-40 to +60C) 3/4"
1/2" CONDUIT 3/4" WALL MOUNTING OFFOR
B-BRACKET ALL
FITTING 1/2 CONDUIT MODELSOF ALL
WALL MOUNTING
1/2" CONDUIT
PART #73866 MODELS
1/2 CONDUIT
1-5/8"D
FITTING
PART #73866
CATALOG UPC VOLTAGE RATING
NO CODE 50-60HZ SWITCH TUNGSTEN BALLAST
120V
2021 60024 120 SPST
MODELS 2000W 1800VA
2022 60025 208-277 SPST 2000W 1800VA
73866 MOUNTING BRACKET
Line (Black) (Red) Lamp
Neutral (White)
WIRING DIAGRAMS
120V 208-277V
MODELS MODELS
Line (Black) (Red) Lamp Line (Black) (Red) Lamp
Neutral L1
(White)
240V
Neutral (White)
L2
For 277VAC
208-277V L1 - Line
MODELS L2 - Neutral
SPECIFICATION WRITERS GUIDE(Red)
Line (Black) Lamp
L1
Photocontrol enclosure shall be constructed of Lexan material. Cover and base shall be ultrasonically welded. Cell shall be cadmium sulphide, epoxy coated, 12 inch diameter.
Contacts shall be normally closed and fail in the ON position. Photocontrol must withstand temperatures of -40to +140F. Unit to be provided with three color coded, minimum six
240V
inch wire leads, #16 AWG, rated for 105C. Photocontrol shall have a xed base for mounting through 78 inch opening or 12 inch K.O. Photocontrol shall have a 180 swivel
Neutral (White)
base for mounting through 78 inch opening or 12 inch K.O. Furnish and install TORK Model 2021, 120VAC, (Model 2022, 208-277VAC).
L2
For 277VAC
L1 - Line
L2 - Neutral
4 Lexan is a registered trademark of the General Electric Co.
A DIVISION OF NSi INDUSTRIES, LLC
2020 SERIES
1
2 CONDUIT MOUNTING, 180 SWIVEL, LEXAN HOUSING
180
APPLICATIONS
SWIVEL
Flood & Patio Lamp Control
Decorative Lighting Control
PENCIL
Ideal for applications where it is essential to aim the
photocell in an exact direction to sense natural light
but avoid articial light.
FEATURES
All Lexan enclosure is impact and vandal resistant,
cover and base are ultrasonically welded for
maximum strength.
Delay of up to two minutes prevents false switching
due to light from vehicles or lightning, etc.
DIMENSIONS MOUNTING
SPECIFICATIONS BRACKET
TURN ON/TURN OFF: Turn ON is 1 to 5fc 1-1/4"D
Turn OFF is 3 to 15fc
2" 1-7/8" 3-1/4"
CELL: Cadmium sulphide, epoxy coated, 12 diameter. 2" 1-7/8" 3-1/4"
CONTACTS: Normally closed.
(The unit fails in the ON position).
3" 3" 4-1/8"
LEAD WIRES: Three color coded, minimum 6 wire leads, 4-1/2"
4-1/2"
MAX.
#16AWG, rated for 105C.
POWER CONSUMPTION: Averages under 1 watt.
TEMPERATURE RANGE: -40 to +140F 3/4" B-BRACKET FOR
(-40 to +60C) 3/4"
1/2" CONDUIT 3/4" WALL MOUNTING OFFOR
B-BRACKET ALL
FITTING 1/2 CONDUIT MODELSOF ALL
WALL MOUNTING
1/2" CONDUIT
PART #73866 MODELS
1/2 CONDUIT
1-5/8"D
FITTING
PART #73866
CATALOG UPC VOLTAGE RATING
NO CODE 50-60HZ SWITCH TUNGSTEN BALLAST
120V
2021 60024 120 SPST
MODELS 2000W 1800VA
2022 60025 208-277 SPST 2000W 1800VA
73866 MOUNTING BRACKET
Line (Black) (Red) Lamp
Neutral (White)
WIRING DIAGRAMS
120V 208-277V
MODELS MODELS
Line (Black) (Red) Lamp Line (Black) (Red) Lamp
Neutral L1
(White)
240V
Neutral (White)
L2
For 277VAC
208-277V L1 - Line
MODELS L2 - Neutral
SPECIFICATION WRITERS GUIDE(Red)
Line (Black) Lamp
L1
Photocontrol enclosure shall be constructed of Lexan material. Cover and base shall be ultrasonically welded. Cell shall be cadmium sulphide, epoxy coated, 12 inch diameter.
Contacts shall be normally closed and fail in the ON position. Photocontrol must withstand temperatures of -40to +140F. Unit to be provided with three color coded, minimum six
240V
inch wire leads, #16 AWG, rated for 105C. Photocontrol shall have a xed base for mounting through 78 inch opening or 12 inch K.O. Photocontrol shall have a 180 swivel
Neutral (White)
base for mounting through 78 inch opening or 12 inch K.O. Furnish and install TORK Model 2021, 120VAC, (Model 2022, 208-277VAC).
L2
For 277VAC
L1 - Line
L2 - Neutral
4 Lexan is a registered trademark of the General Electric Co.
A DIVISION OF NSi INDUSTRIES, LLC
2020 SERIES
1
2 CONDUIT MOUNTING, 180 SWIVEL, LEXAN HOUSING
180
APPLICATIONS
SWIVEL
Flood & Patio Lamp Control
Decorative Lighting Control
PENCIL
Ideal for applications where it is essential to aim the
photocell in an exact direction to sense natural light
but avoid articial light.
FEATURES
All Lexan enclosure is impact and vandal resistant,
cover and base are ultrasonically welded for
maximum strength.
Delay of up to two minutes prevents false switching
due to light from vehicles or lightning, etc.
DIMENSIONS MOUNTING
SPECIFICATIONS BRACKET
TURN ON/TURN OFF: Turn ON is 1 to 5fc 1-1/4"D
Turn OFF is 3 to 15fc
2" 1-7/8" 3-1/4"
CELL: Cadmium sulphide, epoxy coated, 12 diameter. 2" 1-7/8" 3-1/4"
CONTACTS: Normally closed.
(The unit fails in the ON position).
3" 3" 4-1/8"
LEAD WIRES: Three color coded, minimum 6 wire leads, 4-1/2"
4-1/2"
MAX.
#16AWG, rated for 105C.
POWER CONSUMPTION: Averages under 1 watt.
TEMPERATURE RANGE: -40 to +140F 3/4" B-BRACKET FOR
(-40 to +60C) 3/4"
1/2" CONDUIT 3/4" WALL MOUNTING OFFOR
B-BRACKET ALL
FITTING 1/2 CONDUIT MODELSOF ALL
WALL MOUNTING
1/2" CONDUIT
PART #73866 MODELS
1/2 CONDUIT
1-5/8"D
FITTING
PART #73866
CATALOG UPC VOLTAGE RATING
NO CODE 50-60HZ SWITCH TUNGSTEN BALLAST
120V
2021 60024 120 SPST
MODELS 2000W 1800VA
2022 60025 208-277 SPST 2000W 1800VA
73866 MOUNTING BRACKET
Line (Black) (Red) Lamp
Neutral (White)
WIRING DIAGRAMS
120V 208-277V
MODELS MODELS
Line (Black) (Red) Lamp Line (Black) (Red) Lamp
Neutral L1
(White)
240V
Neutral (White)
L2
For 277VAC
208-277V L1 - Line
MODELS L2 - Neutral
SPECIFICATION WRITERS GUIDE(Red)
Line (Black) Lamp
L1
Photocontrol enclosure shall be constructed of Lexan material. Cover and base shall be ultrasonically welded. Cell shall be cadmium sulphide, epoxy coated, 12 inch diameter.
Contacts shall be normally closed and fail in the ON position. Photocontrol must withstand temperatures of -40to +140F. Unit to be provided with three color coded, minimum six
240V
inch wire leads, #16 AWG, rated for 105C. Photocontrol shall have a xed base for mounting through 78 inch opening or 12 inch K.O. Photocontrol shall have a 180 swivel
Neutral (White)
base for mounting through 78 inch opening or 12 inch K.O. Furnish and install TORK Model 2021, 120VAC, (Model 2022, 208-277VAC).
L2
For 277VAC
L1 - Line
L2 - Neutral
4 Lexan is a registered trademark of the General Electric Co.
A DIVISION OF NSi INDUSTRIES, LLC