            CAT                UPC                                                                                                               H.P.     MOTOR:      MOTOR:
NO CODE ENCLOSURE TYPE SWITCH AMPS RATING AC VOLTAGE Hz

7100 10001 Metal Indoor SPST 40 2 120 60
7102 10002 Metal Indoor SPST 40 5 208-277 60
7200 11001 Metal Indoor DPST 40 2 120 60
7202 11002 Metal Indoor DPST 40 5 208-277 60
7300 12001 Metal Indoor/Outdoor 3PST 40 2 120 60
7302 12002 Metal Indoor/Outdoor 3PST 40 5 208-277 60
7120 13001 Metal Indoor SPDT 40 2 120 60
7122 13002 Metal Indoor SPDT 40 5 208-277 60
7220 14001 Metal Indoor DPDT 40 2 120 60
7222 14002 Metal Indoor DPDT 40 5 208-277 60

WITH RESERVE POWER
7200L 19003 Noryl Indoor/Outdoor DPST 40 2 120 60
7202L 19004 Noryl Indoor/Outdoor DPST 40 5 208-277 60
7300L 19005 Metal Indoor/Outdoor 3PST 40 2 120 60
7302L 19006 Metal Indoor/Outdoor 3PST 40 5 208-277 60
7120L 19007 Noryl Indoor/Outdoor SPDT 40 2 120 60
7220L 19009 Noryl Indoor/Outdoor DPDT 40 2 120 60
7222L 19011 Noryl Indoor/Outdoor DPDT 40 5 208-277 60

CONVERSION NOTE: ORDER ZKIT: Astronomic kit for eld conversion of TORK 7000 and 1100 SERIES
24 VOLT IN ALL MODELS AVAILABLE ON SPECIFICATION. Indoor/outdoor Noryl case is standard on all models with reserve power except 3PST is metal
indoor/outdoor.
NOTE 1: If converting to reserve power in the eld, order Model 63100 enclosure to accommodate the larger unit (not necessary with 3PST models)
NOTE 2. When replacing a Model 7300 or 7302 mechanism only into an existing enclosure, order CK7300 conversion kit since the new mechanism is designed
narrower than the old one.


WIRING DIAGRAMS
7100 SPST 7200 DPST 7300 3PST

M M M



L 1 X 2
L 1 X 2
L 2 L
3 4

H LOAD L
LOAD LOAD
N H 5 6
N L
LOAD LOAD LOAD
H
N




7120 SPDT 7220 DPDT

M
M




L 1 X 2 H
L 1 X 2
H LOAD
H
H N
LOAD LOAD
A B L 3 5 4 LOAD



N N LOAD LOAD
H
N
N




SPECIFICATION WRITERS GUIDE 7000 SERIES
Furnish and install where shown a TORK Time Switch with 24 hour dial and day-omitting device. The Time Switch shall be powered by a self-starting synchronous motor.
Time Switch contacts shall be capable of switching 40 amperes per pole continuously at 277 volts and shall be SPST (DPST, 3PST, DPST, SPDT, as required). Removable ON-
OFF trippers shall make possible automatic operation with a minimum ON period of 20 minutes and a minimum of 2 hours between one OFF period and the next. Enclosure
shall be NEMA 1 surface type, nished in beige enamel, with combination 1/2, 3/4 knockouts on bottom, both sides and back. Provision shall be made for positive pad-
locking. Terminals shall be capable of receiving #8 AWG wire. Time Switch shall be TORK Model 7_ _ _ (to t requirement).

FOR RESERVE POWER (MODELS WITH SUFFIX L): Spring-driven reserve shall be provided sufcient to operate the Time Switch contacts at least 16 hours after power fail-
ure. On restoration of power, Time Switch shall transfer to synchronous motor drive and automatically rewind reserve power unit.



5
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
CAT UPC H.P. MOTOR: MOTOR:
NO CODE ENCLOSURE TYPE SWITCH AMPS RATING AC VOLTAGE Hz

7100 10001 Metal Indoor SPST 40 2 120 60
7102 10002 Metal Indoor SPST 40 5 208-277 60
7200 11001 Metal Indoor DPST 40 2 120 60
7202 11002 Metal Indoor DPST 40 5 208-277 60
7300 12001 Metal Indoor/Outdoor 3PST 40 2 120 60
7302 12002 Metal Indoor/Outdoor 3PST 40 5 208-277 60
7120 13001 Metal Indoor SPDT 40 2 120 60
7122 13002 Metal Indoor SPDT 40 5 208-277 60
7220 14001 Metal Indoor DPDT 40 2 120 60
7222 14002 Metal Indoor DPDT 40 5 208-277 60

WITH RESERVE POWER
7200L 19003 Noryl Indoor/Outdoor DPST 40 2 120 60
7202L 19004 Noryl Indoor/Outdoor DPST 40 5 208-277 60
7300L 19005 Metal Indoor/Outdoor 3PST 40 2 120 60
7302L 19006 Metal Indoor/Outdoor 3PST 40 5 208-277 60
7120L 19007 Noryl Indoor/Outdoor SPDT 40 2 120 60
7220L 19009 Noryl Indoor/Outdoor DPDT 40 2 120 60
7222L 19011 Noryl Indoor/Outdoor DPDT 40 5 208-277 60

CONVERSION NOTE: ORDER ZKIT: Astronomic kit for eld conversion of TORK 7000 and 1100 SERIES
24 VOLT IN ALL MODELS AVAILABLE ON SPECIFICATION. Indoor/outdoor Noryl case is standard on all models with reserve power except 3PST is metal
indoor/outdoor.
NOTE 1: If converting to reserve power in the eld, order Model 63100 enclosure to accommodate the larger unit (not necessary with 3PST models)
NOTE 2. When replacing a Model 7300 or 7302 mechanism only into an existing enclosure, order CK7300 conversion kit since the new mechanism is designed
narrower than the old one.


WIRING DIAGRAMS
7100 SPST 7200 DPST 7300 3PST

M M M



L 1 X 2
L 1 X 2
L 2 L
3 4

H LOAD L
LOAD LOAD
N H 5 6
N L
LOAD LOAD LOAD
H
N




7120 SPDT 7220 DPDT

M
M




L 1 X 2 H
L 1 X 2
H LOAD
H
H N
LOAD LOAD
A B L 3 5 4 LOAD



N N LOAD LOAD
H
N
N




SPECIFICATION WRITERS GUIDE 7000 SERIES
Furnish and install where shown a TORK Time Switch with 24 hour dial and day-omitting device. The Time Switch shall be powered by a self-starting synchronous motor.
Time Switch contacts shall be capable of switching 40 amperes per pole continuously at 277 volts and shall be SPST (DPST, 3PST, DPST, SPDT, as required). Removable ON-
OFF trippers shall make possible automatic operation with a minimum ON period of 20 minutes and a minimum of 2 hours between one OFF period and the next. Enclosure
shall be NEMA 1 surface type, nished in beige enamel, with combination 1/2, 3/4 knockouts on bottom, both sides and back. Provision shall be made for positive pad-
locking. Terminals shall be capable of receiving #8 AWG wire. Time Switch shall be TORK Model 7_ _ _ (to t requirement).

FOR RESERVE POWER (MODELS WITH SUFFIX L): Spring-driven reserve shall be provided sufcient to operate the Time Switch contacts at least 16 hours after power fail-
ure. On restoration of power, Time Switch shall transfer to synchronous motor drive and automatically rewind reserve power unit.



5
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
CAT UPC H.P. MOTOR: MOTOR:
NO CODE ENCLOSURE TYPE SWITCH AMPS RATING AC VOLTAGE Hz

7100 10001 Metal Indoor SPST 40 2 120 60
7102 10002 Metal Indoor SPST 40 5 208-277 60
7200 11001 Metal Indoor DPST 40 2 120 60
7202 11002 Metal Indoor DPST 40 5 208-277 60
7300 12001 Metal Indoor/Outdoor 3PST 40 2 120 60
7302 12002 Metal Indoor/Outdoor 3PST 40 5 208-277 60
7120 13001 Metal Indoor SPDT 40 2 120 60
7122 13002 Metal Indoor SPDT 40 5 208-277 60
7220 14001 Metal Indoor DPDT 40 2 120 60
7222 14002 Metal Indoor DPDT 40 5 208-277 60

WITH RESERVE POWER
7200L 19003 Noryl Indoor/Outdoor DPST 40 2 120 60
7202L 19004 Noryl Indoor/Outdoor DPST 40 5 208-277 60
7300L 19005 Metal Indoor/Outdoor 3PST 40 2 120 60
7302L 19006 Metal Indoor/Outdoor 3PST 40 5 208-277 60
7120L 19007 Noryl Indoor/Outdoor SPDT 40 2 120 60
7220L 19009 Noryl Indoor/Outdoor DPDT 40 2 120 60
7222L 19011 Noryl Indoor/Outdoor DPDT 40 5 208-277 60

CONVERSION NOTE: ORDER ZKIT: Astronomic kit for eld conversion of TORK 7000 and 1100 SERIES
24 VOLT IN ALL MODELS AVAILABLE ON SPECIFICATION. Indoor/outdoor Noryl case is standard on all models with reserve power except 3PST is metal
indoor/outdoor.
NOTE 1: If converting to reserve power in the eld, order Model 63100 enclosure to accommodate the larger unit (not necessary with 3PST models)
NOTE 2. When replacing a Model 7300 or 7302 mechanism only into an existing enclosure, order CK7300 conversion kit since the new mechanism is designed
narrower than the old one.


WIRING DIAGRAMS
7100 SPST 7200 DPST 7300 3PST

M M M



L 1 X 2
L 1 X 2
L 2 L
3 4

H LOAD L
LOAD LOAD
N H 5 6
N L
LOAD LOAD LOAD
H
N




7120 SPDT 7220 DPDT

M
M




L 1 X 2 H
L 1 X 2
H LOAD
H
H N
LOAD LOAD
A B L 3 5 4 LOAD



N N LOAD LOAD
H
N
N




SPECIFICATION WRITERS GUIDE 7000 SERIES
Furnish and install where shown a TORK Time Switch with 24 hour dial and day-omitting device. The Time Switch shall be powered by a self-starting synchronous motor.
Time Switch contacts shall be capable of switching 40 amperes per pole continuously at 277 volts and shall be SPST (DPST, 3PST, DPST, SPDT, as required). Removable ON-
OFF trippers shall make possible automatic operation with a minimum ON period of 20 minutes and a minimum of 2 hours between one OFF period and the next. Enclosure
shall be NEMA 1 surface type, nished in beige enamel, with combination 1/2, 3/4 knockouts on bottom, both sides and back. Provision shall be made for positive pad-
locking. Terminals shall be capable of receiving #8 AWG wire. Time Switch shall be TORK Model 7_ _ _ (to t requirement).

FOR RESERVE POWER (MODELS WITH SUFFIX L): Spring-driven reserve shall be provided sufcient to operate the Time Switch contacts at least 16 hours after power fail-
ure. On restoration of power, Time Switch shall transfer to synchronous motor drive and automatically rewind reserve power unit.



5
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
CAT UPC H.P. MOTOR: MOTOR:
NO CODE ENCLOSURE TYPE SWITCH AMPS RATING AC VOLTAGE Hz

7100 10001 Metal Indoor SPST 40 2 120 60
7102 10002 Metal Indoor SPST 40 5 208-277 60
7200 11001 Metal Indoor DPST 40 2 120 60
7202 11002 Metal Indoor DPST 40 5 208-277 60
7300 12001 Metal Indoor/Outdoor 3PST 40 2 120 60
7302 12002 Metal Indoor/Outdoor 3PST 40 5 208-277 60
7120 13001 Metal Indoor SPDT 40 2 120 60
7122 13002 Metal Indoor SPDT 40 5 208-277 60
7220 14001 Metal Indoor DPDT 40 2 120 60
7222 14002 Metal Indoor DPDT 40 5 208-277 60

WITH RESERVE POWER
7200L 19003 Noryl Indoor/Outdoor DPST 40 2 120 60
7202L 19004 Noryl Indoor/Outdoor DPST 40 5 208-277 60
7300L 19005 Metal Indoor/Outdoor 3PST 40 2 120 60
7302L 19006 Metal Indoor/Outdoor 3PST 40 5 208-277 60
7120L 19007 Noryl Indoor/Outdoor SPDT 40 2 120 60
7220L 19009 Noryl Indoor/Outdoor DPDT 40 2 120 60
7222L 19011 Noryl Indoor/Outdoor DPDT 40 5 208-277 60

CONVERSION NOTE: ORDER ZKIT: Astronomic kit for eld conversion of TORK 7000 and 1100 SERIES
24 VOLT IN ALL MODELS AVAILABLE ON SPECIFICATION. Indoor/outdoor Noryl case is standard on all models with reserve power except 3PST is metal
indoor/outdoor.
NOTE 1: If converting to reserve power in the eld, order Model 63100 enclosure to accommodate the larger unit (not necessary with 3PST models)
NOTE 2. When replacing a Model 7300 or 7302 mechanism only into an existing enclosure, order CK7300 conversion kit since the new mechanism is designed
narrower than the old one.


WIRING DIAGRAMS
7100 SPST 7200 DPST 7300 3PST

M M M



L 1 X 2
L 1 X 2
L 2 L
3 4

H LOAD L
LOAD LOAD
N H 5 6
N L
LOAD LOAD LOAD
H
N




7120 SPDT 7220 DPDT

M
M




L 1 X 2 H
L 1 X 2
H LOAD
H
H N
LOAD LOAD
A B L 3 5 4 LOAD



N N LOAD LOAD
H
N
N




SPECIFICATION WRITERS GUIDE 7000 SERIES
Furnish and install where shown a TORK Time Switch with 24 hour dial and day-omitting device. The Time Switch shall be powered by a self-starting synchronous motor.
Time Switch contacts shall be capable of switching 40 amperes per pole continuously at 277 volts and shall be SPST (DPST, 3PST, DPST, SPDT, as required). Removable ON-
OFF trippers shall make possible automatic operation with a minimum ON period of 20 minutes and a minimum of 2 hours between one OFF period and the next. Enclosure
shall be NEMA 1 surface type, nished in beige enamel, with combination 1/2, 3/4 knockouts on bottom, both sides and back. Provision shall be made for positive pad-
locking. Terminals shall be capable of receiving #8 AWG wire. Time Switch shall be TORK Model 7_ _ _ (to t requirement).

FOR RESERVE POWER (MODELS WITH SUFFIX L): Spring-driven reserve shall be provided sufcient to operate the Time Switch contacts at least 16 hours after power fail-
ure. On restoration of power, Time Switch shall transfer to synchronous motor drive and automatically rewind reserve power unit.



5
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
CAT UPC MOTOR: MOTOR: ENCLOSURE
NO CODE SWITCH AMPS AC VOLTAGE Hz TYPE

7200Z 21001 DPST 40 120 60 Noryl Indoor/Outdoor
7202Z 21002 DPST 40 208-277 60 Noryl Indoor/Outdoor
7300Z 22001 3PST 40 120 60 Metal Indoor/Outdoor
7302Z 22002 3PST 40 208-277 60 Metal Indoor/Outdoor
7120Z 23001 SPDT 40 120 60 Noryl Indoor/Outdoor

WITH RESERVE POWER
7200ZL 29003 DPST 40 120 60 Noryl Indoor/Outdoor
7202ZL 29013 DPST 40 208-277 60 Noryl Indoor/Outdoor
7300ZL 29005 3PST 40 120 60 Metal Indoor/Outdoor
7302ZL 29015 3PST 40 208-277 60 Metal Indoor/Outdoor
7120ZL 29007 SPDT 40 120 60 Noryl Indoor/Outdoor
7122ZL 29017 SPDT 40 208-277 60 Noryl Indoor/Outdoor


24 VOLT IN ALL MODELS AVAILABLE ON SPECIFICATION.
NOTE 1: When replacing a Model 7300 or 7302 mechanism only into an existing enclosure, order CK7300 conversion kit since the new mechanism is designed
narrower than the old one.




WIRING DIAGRAMS

7200Z (DPST) 7300Z (3PST) 7120Z (SPDT)
M M M



L 1 X 2
L 1 X 2
L
L 1 X 2
3 4
N
LOAD LOAD L H
H LOAD LOAD
5 6 A B
N
L
H LOAD LOAD LOAD N H
N

FOR USE WITH 3 PHASE 4-WIRE
120/208V SYSTEMS.




SPECIFICATION WRITERS GUIDE 7000Z SERIES
Furnish and install where shown a TORK Time Switch with Astronomic dial and day-omitting device powered by a self-starting synchronous motor. Time Switch contacts shall
be capable of switching 40 amperes per pole continuously at 277 volts and shall be (DPST, 3PST or SPDT) as required. ON operation shall occur automatically at sunset (in
city of use). OFF operation shall be adjustable from 8:30 P.M. to 2:30 A.M. in one-half hour increments or at sunrise. Both ON and OFF shall have a range of adjustabili-
ty of 20-40 minutes before or after sunset and sunrise. Enclosure shall be: DPST or SPDT is NEMA 3R indoor/outdoor Noryl 3PST is NEMA 3 metal indoor/outdoor.
Terminals shall be of the pressure type, capable of receiving #8 AWG wire. Time Switch shall be TORK Model 7_ _ _Z (to t requirement).

FOR RESERVE POWER (Add Sufx L): Spring driven reserve shall be provided sufcient to operate the Time Switch contacts at least 16 hours after power failure. On restora-
tion of power, Time Switch shall transfer to synchronous motor drive and automatically rewind reserve power unit.




9
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
CAT UPC MOTOR: MOTOR: ENCLOSURE
NO CODE SWITCH AMPS AC VOLTAGE Hz TYPE

7200Z 21001 DPST 40 120 60 Noryl Indoor/Outdoor
7202Z 21002 DPST 40 208-277 60 Noryl Indoor/Outdoor
7300Z 22001 3PST 40 120 60 Metal Indoor/Outdoor
7302Z 22002 3PST 40 208-277 60 Metal Indoor/Outdoor
7120Z 23001 SPDT 40 120 60 Noryl Indoor/Outdoor

WITH RESERVE POWER
7200ZL 29003 DPST 40 120 60 Noryl Indoor/Outdoor
7202ZL 29013 DPST 40 208-277 60 Noryl Indoor/Outdoor
7300ZL 29005 3PST 40 120 60 Metal Indoor/Outdoor
7302ZL 29015 3PST 40 208-277 60 Metal Indoor/Outdoor
7120ZL 29007 SPDT 40 120 60 Noryl Indoor/Outdoor
7122ZL 29017 SPDT 40 208-277 60 Noryl Indoor/Outdoor


24 VOLT IN ALL MODELS AVAILABLE ON SPECIFICATION.
NOTE 1: When replacing a Model 7300 or 7302 mechanism only into an existing enclosure, order CK7300 conversion kit since the new mechanism is designed
narrower than the old one.




WIRING DIAGRAMS

7200Z (DPST) 7300Z (3PST) 7120Z (SPDT)
M M M



L 1 X 2
L 1 X 2
L
L 1 X 2
3 4
N
LOAD LOAD L H
H LOAD LOAD
5 6 A B
N
L
H LOAD LOAD LOAD N H
N

FOR USE WITH 3 PHASE 4-WIRE
120/208V SYSTEMS.




SPECIFICATION WRITERS GUIDE 7000Z SERIES
Furnish and install where shown a TORK Time Switch with Astronomic dial and day-omitting device powered by a self-starting synchronous motor. Time Switch contacts shall
be capable of switching 40 amperes per pole continuously at 277 volts and shall be (DPST, 3PST or SPDT) as required. ON operation shall occur automatically at sunset (in
city of use). OFF operation shall be adjustable from 8:30 P.M. to 2:30 A.M. in one-half hour increments or at sunrise. Both ON and OFF shall have a range of adjustabili-
ty of 20-40 minutes before or after sunset and sunrise. Enclosure shall be: DPST or SPDT is NEMA 3R indoor/outdoor Noryl 3PST is NEMA 3 metal indoor/outdoor.
Terminals shall be of the pressure type, capable of receiving #8 AWG wire. Time Switch shall be TORK Model 7_ _ _Z (to t requirement).

FOR RESERVE POWER (Add Sufx L): Spring driven reserve shall be provided sufcient to operate the Time Switch contacts at least 16 hours after power failure. On restora-
tion of power, Time Switch shall transfer to synchronous motor drive and automatically rewind reserve power unit.




9
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
CAT UPC MOTOR: MOTOR: ENCLOSURE
NO CODE SWITCH AMPS AC VOLTAGE Hz TYPE

7200Z 21001 DPST 40 120 60 Noryl Indoor/Outdoor
7202Z 21002 DPST 40 208-277 60 Noryl Indoor/Outdoor
7300Z 22001 3PST 40 120 60 Metal Indoor/Outdoor
7302Z 22002 3PST 40 208-277 60 Metal Indoor/Outdoor
7120Z 23001 SPDT 40 120 60 Noryl Indoor/Outdoor

WITH RESERVE POWER
7200ZL 29003 DPST 40 120 60 Noryl Indoor/Outdoor
7202ZL 29013 DPST 40 208-277 60 Noryl Indoor/Outdoor
7300ZL 29005 3PST 40 120 60 Metal Indoor/Outdoor
7302ZL 29015 3PST 40 208-277 60 Metal Indoor/Outdoor
7120ZL 29007 SPDT 40 120 60 Noryl Indoor/Outdoor
7122ZL 29017 SPDT 40 208-277 60 Noryl Indoor/Outdoor


24 VOLT IN ALL MODELS AVAILABLE ON SPECIFICATION.
NOTE 1: When replacing a Model 7300 or 7302 mechanism only into an existing enclosure, order CK7300 conversion kit since the new mechanism is designed
narrower than the old one.




WIRING DIAGRAMS

7200Z (DPST) 7300Z (3PST) 7120Z (SPDT)
M M M



L 1 X 2
L 1 X 2
L
L 1 X 2
3 4
N
LOAD LOAD L H
H LOAD LOAD
5 6 A B
N
L
H LOAD LOAD LOAD N H
N

FOR USE WITH 3 PHASE 4-WIRE
120/208V SYSTEMS.




SPECIFICATION WRITERS GUIDE 7000Z SERIES
Furnish and install where shown a TORK Time Switch with Astronomic dial and day-omitting device powered by a self-starting synchronous motor. Time Switch contacts shall
be capable of switching 40 amperes per pole continuously at 277 volts and shall be (DPST, 3PST or SPDT) as required. ON operation shall occur automatically at sunset (in
city of use). OFF operation shall be adjustable from 8:30 P.M. to 2:30 A.M. in one-half hour increments or at sunrise. Both ON and OFF shall have a range of adjustabili-
ty of 20-40 minutes before or after sunset and sunrise. Enclosure shall be: DPST or SPDT is NEMA 3R indoor/outdoor Noryl 3PST is NEMA 3 metal indoor/outdoor.
Terminals shall be of the pressure type, capable of receiving #8 AWG wire. Time Switch shall be TORK Model 7_ _ _Z (to t requirement).

FOR RESERVE POWER (Add Sufx L): Spring driven reserve shall be provided sufcient to operate the Time Switch contacts at least 16 hours after power failure. On restora-
tion of power, Time Switch shall transfer to synchronous motor drive and automatically rewind reserve power unit.




9
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
CAT UPC MOTOR: MOTOR: ENCLOSURE
NO CODE SWITCH AMPS AC VOLTAGE Hz TYPE

7200Z 21001 DPST 40 120 60 Noryl Indoor/Outdoor
7202Z 21002 DPST 40 208-277 60 Noryl Indoor/Outdoor
7300Z 22001 3PST 40 120 60 Metal Indoor/Outdoor
7302Z 22002 3PST 40 208-277 60 Metal Indoor/Outdoor
7120Z 23001 SPDT 40 120 60 Noryl Indoor/Outdoor

WITH RESERVE POWER
7200ZL 29003 DPST 40 120 60 Noryl Indoor/Outdoor
7202ZL 29013 DPST 40 208-277 60 Noryl Indoor/Outdoor
7300ZL 29005 3PST 40 120 60 Metal Indoor/Outdoor
7302ZL 29015 3PST 40 208-277 60 Metal Indoor/Outdoor
7120ZL 29007 SPDT 40 120 60 Noryl Indoor/Outdoor
7122ZL 29017 SPDT 40 208-277 60 Noryl Indoor/Outdoor


24 VOLT IN ALL MODELS AVAILABLE ON SPECIFICATION.
NOTE 1: When replacing a Model 7300 or 7302 mechanism only into an existing enclosure, order CK7300 conversion kit since the new mechanism is designed
narrower than the old one.




WIRING DIAGRAMS

7200Z (DPST) 7300Z (3PST) 7120Z (SPDT)
M M M



L 1 X 2
L 1 X 2
L
L 1 X 2
3 4
N
LOAD LOAD L H
H LOAD LOAD
5 6 A B
N
L
H LOAD LOAD LOAD N H
N

FOR USE WITH 3 PHASE 4-WIRE
120/208V SYSTEMS.




SPECIFICATION WRITERS GUIDE 7000Z SERIES
Furnish and install where shown a TORK Time Switch with Astronomic dial and day-omitting device powered by a self-starting synchronous motor. Time Switch contacts shall
be capable of switching 40 amperes per pole continuously at 277 volts and shall be (DPST, 3PST or SPDT) as required. ON operation shall occur automatically at sunset (in
city of use). OFF operation shall be adjustable from 8:30 P.M. to 2:30 A.M. in one-half hour increments or at sunrise. Both ON and OFF shall have a range of adjustabili-
ty of 20-40 minutes before or after sunset and sunrise. Enclosure shall be: DPST or SPDT is NEMA 3R indoor/outdoor Noryl 3PST is NEMA 3 metal indoor/outdoor.
Terminals shall be of the pressure type, capable of receiving #8 AWG wire. Time Switch shall be TORK Model 7_ _ _Z (to t requirement).

FOR RESERVE POWER (Add Sufx L): Spring driven reserve shall be provided sufcient to operate the Time Switch contacts at least 16 hours after power failure. On restora-
tion of power, Time Switch shall transfer to synchronous motor drive and automatically rewind reserve power unit.




9
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
ACCESSORIES
CAT UPC
NO CODE DESCRIPTION

PK100 95110 Parts Kit includes parts cabinet and 24 P47, 5 P49, 28 P69, 10 P14, 4 101M motors, 2 201M motors.
P-47 95001 Pair Standard Screw-On Type Trippers for 1100 Series (except FM models)
and all 7000 and 1800 Series models. Does not advance day omitting wheel.
K24 95026 Kit of 24 pairs of P-47 Trippers.
PF48 95003 Pair of standard trippers for 1100 FM Series.
P-49 95002 Special ON tripper for 7000 Series to also advance day omitting wheel. Standard OFF tripper included.
P-69 85003 Screw-On Type Trippers reversible ON and OFF for use on all models with 612 dia.
7 day dial (except W400 Series). Available only in packages of 7 pairs.
P-69I 85004 ON and OFF Trippers for W400 Series. Available only in packages of 7 pairs.
P-41 95400 ON & OFF trippers for plug-in timers Models 401, 421, 431.
P-14 95006 Omitting screws for inserting into tapped hole of appropriate spoke of day omitting wheel. Color: Black.
P-26 95007 Selector screws for 4000 (Double Dial) Series Provides Extra Operations Daily. Color: Copper
KN500 95027 For 2 conduit. Grounding bushings for use with Noryl enclosures and metal conduit. Fits #10-14 AWG ground wires. 2 bushings per kit.
1


KN750 95028 For 34 conduit. Grounding bushings for use with Noryl enclosures and metal conduit. Fits #10-14 AWG ground wires. 2 bushings per kit.
64140 95008 480/120v Step-down Transformer only for 480v power input. 7.8 VA (for use with Model 7100, 8001, 8007 only).
71018 95009 24/120V Step-up Transformer. 50VA.



Mounting Brackets for mounting unit less case. Specify CAT UPC
model number, date of manufacture, and whether NO CODE DESCRIPTION
model mounts by snapping into case, or with screws.

MODEL NO: 65447 70159 95050 W. Dial for T900, TW, 1847AW,
and W controls except W400A
UPC CODE: 95020
All 24 hour models except 3-pole, 73713-4 95051 24 hour dial for 7100 Series
including reserve power models 73713-5 95052 24 hour dial for 1100 Series, 1847A Series
53032-17 95053 FM Series dial for 1100FM; 1100FMM
MODEL NO: 64040 (CK-7300) 64041 95054 8001 Dial
UPC CODE: 95023
64041-1 95055 8007 Dial
24 Hour 3-pole for Models 7300, 7302.
64041-2 95056 8601 Dial
64041-6 95059 8301 Dial
MODEL NO: 64039
64041-5 95058 8121 Dial
UPC CODE: 95021
for W SERIES 7 Day Models: 64041-4 95057 8061 Dial
W100, W200, W202, W120, W220, W222. 73855 95060 Wallplate for 701A
73856-1 95061 Wallplate for 701A-2G
MODEL NO: 62153-1 90031-17 95062 Relay for T-900 Series
UPC CODE: 95022 74240-2 95063 White Knob for A500 Series
W SERIES 7 Day 3-pole for Models W300, 74240-I 95064 Ivory Knob for A500 Series
W302.
74240-3 95065 Black Knob for C500 Series
59201-1 95024 Micro-switch for 8001 and M8000 units
59201-26 95025 Micro-switch for 8007 units
73192-3 95030 Adapter plate allows DG series to snap into
7 day (W Series) Time Switch Enclosure




25
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
ACCESSORIES
CAT UPC
NO CODE DESCRIPTION

PK100 95110 Parts Kit includes parts cabinet and 24 P47, 5 P49, 28 P69, 10 P14, 4 101M motors, 2 201M motors.
P-47 95001 Pair Standard Screw-On Type Trippers for 1100 Series (except FM models)
and all 7000 and 1800 Series models. Does not advance day omitting wheel.
K24 95026 Kit of 24 pairs of P-47 Trippers.
PF48 95003 Pair of standard trippers for 1100 FM Series.
P-49 95002 Special ON tripper for 7000 Series to also advance day omitting wheel. Standard OFF tripper included.
P-69 85003 Screw-On Type Trippers reversible ON and OFF for use on all models with 612 dia.
7 day dial (except W400 Series). Available only in packages of 7 pairs.
P-69I 85004 ON and OFF Trippers for W400 Series. Available only in packages of 7 pairs.
P-41 95400 ON & OFF trippers for plug-in timers Models 401, 421, 431.
P-14 95006 Omitting screws for inserting into tapped hole of appropriate spoke of day omitting wheel. Color: Black.
P-26 95007 Selector screws for 4000 (Double Dial) Series Provides Extra Operations Daily. Color: Copper
KN500 95027 For 2 conduit. Grounding bushings for use with Noryl enclosures and metal conduit. Fits #10-14 AWG ground wires. 2 bushings per kit.
1


KN750 95028 For 34 conduit. Grounding bushings for use with Noryl enclosures and metal conduit. Fits #10-14 AWG ground wires. 2 bushings per kit.
64140 95008 480/120v Step-down Transformer only for 480v power input. 7.8 VA (for use with Model 7100, 8001, 8007 only).
71018 95009 24/120V Step-up Transformer. 50VA.



Mounting Brackets for mounting unit less case. Specify CAT UPC
model number, date of manufacture, and whether NO CODE DESCRIPTION
model mounts by snapping into case, or with screws.

MODEL NO: 65447 70159 95050 W. Dial for T900, TW, 1847AW,
and W controls except W400A
UPC CODE: 95020
All 24 hour models except 3-pole, 73713-4 95051 24 hour dial for 7100 Series
including reserve power models 73713-5 95052 24 hour dial for 1100 Series, 1847A Series
53032-17 95053 FM Series dial for 1100FM; 1100FMM
MODEL NO: 64040 (CK-7300) 64041 95054 8001 Dial
UPC CODE: 95023
64041-1 95055 8007 Dial
24 Hour 3-pole for Models 7300, 7302.
64041-2 95056 8601 Dial
64041-6 95059 8301 Dial
MODEL NO: 64039
64041-5 95058 8121 Dial
UPC CODE: 95021
for W SERIES 7 Day Models: 64041-4 95057 8061 Dial
W100, W200, W202, W120, W220, W222. 73855 95060 Wallplate for 701A
73856-1 95061 Wallplate for 701A-2G
MODEL NO: 62153-1 90031-17 95062 Relay for T-900 Series
UPC CODE: 95022 74240-2 95063 White Knob for A500 Series
W SERIES 7 Day 3-pole for Models W300, 74240-I 95064 Ivory Knob for A500 Series
W302.
74240-3 95065 Black Knob for C500 Series
59201-1 95024 Micro-switch for 8001 and M8000 units
59201-26 95025 Micro-switch for 8007 units
73192-3 95030 Adapter plate allows DG series to snap into
7 day (W Series) Time Switch Enclosure




25
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
ENCLOSURE & MECHANISM DIMENSIONS
METAL INDOOR NEMA 1 METAL INDOOR/OUTDOOR 5-1/4"

#68229 NEMA 3
STD. FOR
MODELS
4-11/16" Model 9000A Suffix O 8-1/4"
1101 7200 8121
1102 7202 8301 STD. FOR MODELS
1103 7120 8601 7-15/16"
7300, (L) 7302Z
1104 7122 8602 7302, (L) 7300ZL 4-5/8"


1101FM 8001 TORK 7300Z 7302ZL
1104FM 8004
AVAILABLE FOR MODELS
7100 8061
2-15/16" 1101 7200, (L,Z,ZL) 1847AL 8007V
7102 1102 7202, (L,Z,ZL) 1847AZL 8061
1103 7120, (L,Z,ZL) 8001 8121
1104 7122, (L,ZL) 8004 8301
1101FM 7220, (L) 8001U 8601
1104FM 7222, (L) 8007 8602
METAL INDOOR NEMA 1 7100 1847A 8007L
#63100 7102 1847AZ
5"
STD. FOR MODELS
7220, (L) 1847AL
7222, (L) 1847AZL
7200L 8007 9-1/4"
7202L 8007L
METAL INDOOR/OUTDOOR
7120L 8007V
NEMA 3 8-3/8 "


1847A 8150
TORK
Model 9006 Suffix O
1848A 8150U AVAILABLE FOR MODELS
1849A W100 W220 TW220L 13-1/8"

3-3/4" W200 W222 TW300L
1847AZ
W202 W220L T920L
W300 W222L T930L
W302 W300L 1847AW
W120 W302L 1847AWL 5-3/16 "

METAL INDOOR NEMA 1
#63016-1 8-1/8"


STD. FOR MODELS
TZ220L W302L
5"
12-1/8 "
TZ300L TW220L NORYL INDOOR/OUTDOOR


W300 TW300L
TORK NEMA 3R
W302 T920L
W300L T930L
Model 9000N Suffix N 9-1/8"


STD. FOR MODELS
4-3/4"
7200Z,(L, ZL) TORK


7202Z,(L, ZL)
7120Z,(L, ZL)
4-1/2"
7122Z, (L, ZL)
METAL INDOOR NEMA 1 AVAILABLE FOR MODELS
#70100 7-5/8 " 1101 7102 7222, (L) 8001U
1102 7200, (L) 1847A 8061
STD. FOR MODELS 1103 7202, (L) 1847AZ 8121
W100 W222 1104 7120, (L) 1847AL 8301
1101FM 7122, (L) 1847AZL 8601
W200 W220L
11-7/8 "
1104FM 7220, (L) 8001 8602
W202 W222L 7100 8004
W120 1847AW TORK



W220 1847AWL

3-1/4 "




METAL INDOOR NEMA 1 NORYL & LEXAN 5"

for W400 Series NEMA 3R
12 -1/2" INDOOR/OUTDOOR TORK 9-1/8"
STD. FOR MODELS Model 9000NC
W400A W400AL
STD. FOR MODELS
W402A W402AL 1101NC
4" 1103NC
4-1/2"
8 -1/4" 1104NC




26
A DIVISION OF NSi INDUSTRIES, LLC
ENCLOSURE & MECHANISM DIMENSIONS
METAL INDOOR NEMA 1 METAL INDOOR/OUTDOOR 5-1/4"

#68229 NEMA 3
STD. FOR
MODELS
4-11/16" Model 9000A Suffix O 8-1/4"
1101 7200 8121
1102 7202 8301 STD. FOR MODELS
1103 7120 8601 7-15/16"
7300, (L) 7302Z
1104 7122 8602 7302, (L) 7300ZL 4-5/8"


1101FM 8001 TORK 7300Z 7302ZL
1104FM 8004
AVAILABLE FOR MODELS
7100 8061
2-15/16" 1101 7200, (L,Z,ZL) 1847AL 8007V
7102 1102 7202, (L,Z,ZL) 1847AZL 8061
1103 7120, (L,Z,ZL) 8001 8121
1104 7122, (L,ZL) 8004 8301
1101FM 7220, (L) 8001U 8601
1104FM 7222, (L) 8007 8602
METAL INDOOR NEMA 1 7100 1847A 8007L
#63100 7102 1847AZ
5"
STD. FOR MODELS
7220, (L) 1847AL
7222, (L) 1847AZL
7200L 8007 9-1/4"
7202L 8007L
METAL INDOOR/OUTDOOR
7120L 8007V
NEMA 3 8-3/8 "


1847A 8150
TORK
Model 9006 Suffix O
1848A 8150U AVAILABLE FOR MODELS
1849A W100 W220 TW220L 13-1/8"

3-3/4" W200 W222 TW300L
1847AZ
W202 W220L T920L
W300 W222L T930L
W302 W300L 1847AW
W120 W302L 1847AWL 5-3/16 "

METAL INDOOR NEMA 1
#63016-1 8-1/8"


STD. FOR MODELS
TZ220L W302L
5"
12-1/8 "
TZ300L TW220L NORYL INDOOR/OUTDOOR


W300 TW300L
TORK NEMA 3R
W302 T920L
W300L T930L
Model 9000N Suffix N 9-1/8"


STD. FOR MODELS
4-3/4"
7200Z,(L, ZL) TORK


7202Z,(L, ZL)
7120Z,(L, ZL)
4-1/2"
7122Z, (L, ZL)
METAL INDOOR NEMA 1 AVAILABLE FOR MODELS
#70100 7-5/8 " 1101 7102 7222, (L) 8001U
1102 7200, (L) 1847A 8061
STD. FOR MODELS 1103 7202, (L) 1847AZ 8121
W100 W222 1104 7120, (L) 1847AL 8301
1101FM 7122, (L) 1847AZL 8601
W200 W220L
11-7/8 "
1104FM 7220, (L) 8001 8602
W202 W222L 7100 8004
W120 1847AW TORK



W220 1847AWL

3-1/4 "




METAL INDOOR NEMA 1 NORYL & LEXAN 5"

for W400 Series NEMA 3R
12 -1/2" INDOOR/OUTDOOR TORK 9-1/8"
STD. FOR MODELS Model 9000NC
W400A W400AL
STD. FOR MODELS
W402A W402AL 1101NC
4" 1103NC
4-1/2"
8 -1/4" 1104NC




26
A DIVISION OF NSi INDUSTRIES, LLC
ENCLOSURE & MECHANISM DIMENSIONS
METAL INDOOR NEMA 1 METAL INDOOR/OUTDOOR 5-1/4"

#68229 NEMA 3
STD. FOR
MODELS
4-11/16" Model 9000A Suffix O 8-1/4"
1101 7200 8121
1102 7202 8301 STD. FOR MODELS
1103 7120 8601 7-15/16"
7300, (L) 7302Z
1104 7122 8602 7302, (L) 7300ZL 4-5/8"


1101FM 8001 TORK 7300Z 7302ZL
1104FM 8004
AVAILABLE FOR MODELS
7100 8061
2-15/16" 1101 7200, (L,Z,ZL) 1847AL 8007V
7102 1102 7202, (L,Z,ZL) 1847AZL 8061
1103 7120, (L,Z,ZL) 8001 8121
1104 7122, (L,ZL) 8004 8301
1101FM 7220, (L) 8001U 8601
1104FM 7222, (L) 8007 8602
METAL INDOOR NEMA 1 7100 1847A 8007L
#63100 7102 1847AZ
5"
STD. FOR MODELS
7220, (L) 1847AL
7222, (L) 1847AZL
7200L 8007 9-1/4"
7202L 8007L
METAL INDOOR/OUTDOOR
7120L 8007V
NEMA 3 8-3/8 "


1847A 8150
TORK
Model 9006 Suffix O
1848A 8150U AVAILABLE FOR MODELS
1849A W100 W220 TW220L 13-1/8"

3-3/4" W200 W222 TW300L
1847AZ
W202 W220L T920L
W300 W222L T930L
W302 W300L 1847AW
W120 W302L 1847AWL 5-3/16 "

METAL INDOOR NEMA 1
#63016-1 8-1/8"


STD. FOR MODELS
TZ220L W302L
5"
12-1/8 "
TZ300L TW220L NORYL INDOOR/OUTDOOR


W300 TW300L
TORK NEMA 3R
W302 T920L
W300L T930L
Model 9000N Suffix N 9-1/8"


STD. FOR MODELS
4-3/4"
7200Z,(L, ZL) TORK


7202Z,(L, ZL)
7120Z,(L, ZL)
4-1/2"
7122Z, (L, ZL)
METAL INDOOR NEMA 1 AVAILABLE FOR MODELS
#70100 7-5/8 " 1101 7102 7222, (L) 8001U
1102 7200, (L) 1847A 8061
STD. FOR MODELS 1103 7202, (L) 1847AZ 8121
W100 W222 1104 7120, (L) 1847AL 8301
1101FM 7122, (L) 1847AZL 8601
W200 W220L
11-7/8 "
1104FM 7220, (L) 8001 8602
W202 W222L 7100 8004
W120 1847AW TORK



W220 1847AWL

3-1/4 "




METAL INDOOR NEMA 1 NORYL & LEXAN 5"

for W400 Series NEMA 3R
12 -1/2" INDOOR/OUTDOOR TORK 9-1/8"
STD. FOR MODELS Model 9000NC
W400A W400AL
STD. FOR MODELS
W402A W402AL 1101NC
4" 1103NC
4-1/2"
8 -1/4" 1104NC




26
A DIVISION OF NSi INDUSTRIES, LLC
METAL DUPLEX METAL FLUSH NEMA 1
NEMA 3 10-3/8" Model 9001 Suffix FL1
INDOOR/OUTDOOR Model 9002 Suffix FL2*
Model 9004L 8"
11-9/32 "
Suffix DUOL AVAILABLE FOR MODELS
1101 7200, (L,Z,ZL)
STD. FOR MODELS
1102 7202, (L,Z,ZL)
1101D 1101DF 7120, (L,Z,ZL)
1103 11" 9-1/8"
1114D 1114DF 1104 7122, (ZL)
4-1/4"
1104D 1104DF 1101FM 7220, (L)
AVAIL. FOR MODELS 1104FM 7222, (L)
6-1/8"
1101 7100 7100 8000 Series
4-3/16"
1102 7102 7102
1103 7200, (L,Z,ZL)
1104 7202, (L,Z,ZL) *Model 9002 (FL2) Depth is 4-9/16
1101FM 7120, (L,Z,ZL) For Models 7300 and 7302
1104FM 7122, (ZL)
7220, (L)
7222, (L)
MODELS
4-9/16"
8601
8602
MODELS:
1101 1847A 4-9/16" 3-1/2" 8301 5-3/4"

1102 1848A 8121
1103 8061
1849A 3-1/2"
1104
1847AZ MECHANISM WITH MOUNTING
1101FM 7-1/2"
1848AZ ONLY BRACKET
1104FM #65447
1849AZ
7100
7102 1847AL 7-5/8"
3-1/2"

7200, (L,Z,ZL) 1848AL MODELS
2-1/2"

7202, (L,Z,ZL) 1849AL MECHANISM WITH MOUNTING W100
ONLY BRACKET W200
11-1/2"

7120, (L,Z,ZL) 1847AZL #65447
W202
7122, (ZL) 1848AZL W120
7220, (L)
1849AZL W220 MECHANISM WITH MOUNTING
7222, (L) ONLY BRACKET
W222
#64039
4-1/4"
4-9/16"

MODELS: 7-5/8"
7300, (L,Z,ZL) 3-5/8 "

7302, (L,Z,ZL)
7-1/2" MODELS 3-1/16"

W300
11-1/2"
W302



MECHANISM WITH MOUNTING
ONLY BRACKET MECHANISM WITH MOUNTING
#64040 ONLY BRACKET
#62153-1

MODELS 4-9/16"
7-3/4" 3-1/2"

8001 MODELS
8004 1847AWL
5-5/8" 11-1/2"
8007 1848AWL

8008 1849AWL
3-1/2"


MECHANISM WITH MOUNTING MECHANISM WITH MOUNTING
ONLY BRACKET ONLY BRACKET
#65447 #65447


27
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
METAL DUPLEX METAL FLUSH NEMA 1
NEMA 3 10-3/8" Model 9001 Suffix FL1
INDOOR/OUTDOOR Model 9002 Suffix FL2*
Model 9004L 8"
11-9/32 "
Suffix DUOL AVAILABLE FOR MODELS
1101 7200, (L,Z,ZL)
STD. FOR MODELS
1102 7202, (L,Z,ZL)
1101D 1101DF 7120, (L,Z,ZL)
1103 11" 9-1/8"
1114D 1114DF 1104 7122, (ZL)
4-1/4"
1104D 1104DF 1101FM 7220, (L)
AVAIL. FOR MODELS 1104FM 7222, (L)
6-1/8"
1101 7100 7100 8000 Series
4-3/16"
1102 7102 7102
1103 7200, (L,Z,ZL)
1104 7202, (L,Z,ZL) *Model 9002 (FL2) Depth is 4-9/16
1101FM 7120, (L,Z,ZL) For Models 7300 and 7302
1104FM 7122, (ZL)
7220, (L)
7222, (L)
MODELS
4-9/16"
8601
8602
MODELS:
1101 1847A 4-9/16" 3-1/2" 8301 5-3/4"

1102 1848A 8121
1103 8061
1849A 3-1/2"
1104
1847AZ MECHANISM WITH MOUNTING
1101FM 7-1/2"
1848AZ ONLY BRACKET
1104FM #65447
1849AZ
7100
7102 1847AL 7-5/8"
3-1/2"

7200, (L,Z,ZL) 1848AL MODELS
2-1/2"

7202, (L,Z,ZL) 1849AL MECHANISM WITH MOUNTING W100
ONLY BRACKET W200
11-1/2"

7120, (L,Z,ZL) 1847AZL #65447
W202
7122, (ZL) 1848AZL W120
7220, (L)
1849AZL W220 MECHANISM WITH MOUNTING
7222, (L) ONLY BRACKET
W222
#64039
4-1/4"
4-9/16"

MODELS: 7-5/8"
7300, (L,Z,ZL) 3-5/8 "

7302, (L,Z,ZL)
7-1/2" MODELS 3-1/16"

W300
11-1/2"
W302



MECHANISM WITH MOUNTING
ONLY BRACKET MECHANISM WITH MOUNTING
#64040 ONLY BRACKET
#62153-1

MODELS 4-9/16"
7-3/4" 3-1/2"

8001 MODELS
8004 1847AWL
5-5/8" 11-1/2"
8007 1848AWL

8008 1849AWL
3-1/2"


MECHANISM WITH MOUNTING MECHANISM WITH MOUNTING
ONLY BRACKET ONLY BRACKET
#65447 #65447


27
JUNE 2007 A DIVISION OF NSi INDUSTRIES, LLC
Miniterms
VINYL-INSULATED, HIGH TEMPERATURE & NYLON-INSULATED RING TERMINALS


VINYL-INSULATED RING TERMINALS NYLON-INSULATED RING TERMINALS




CATALOG UPC WIRE STUD CTN. CATALOG NAED WIRE STUD CTN.
NO. CODE SIZE SIZE LENGTH WIDTH QTY. NO. NO. SIZE SIZE LENGTH WIDTH QTY.

R22-6V 06000 22-18 6 .831 .315 100 R22-6N 07300 22-18 6 .831 .315 100
R22-8V 06001 22-18 8 .827 .315 100 R22-8N 07301 22-18 8 .827 .315 100
R22-10V 06002 22-18 10 .827 .315 100 R22-10N 07302 22-18 10 .827 .315 100
R22-14V 06003 22-18 1/4 1.008 .472 100 R22-14N 07303 22-18 1/4 1.008 .472 100
R22-56V 06004 22-18 5/16 1.028 .472 100 R22-56N 07304 22-18 5/16 1.025 .472 100
R22-38V 06005 22-18 3/8 1.217 .650 100 R22-38N 07305 22-18 3/8 1.217 .650 100
R16-6V 06006 16-14 6 .717 .256 100 R16-6N 07306 16-14 6 .717 .256 100
R16-8V 06007 16-14 8 .846 .315 100 R16-8N 07307 16-14 8 .846 .315 100
R16-10V 06008 16-14 10 .846 .315 100 R16-10N 07308 16-14 10 .846 .315 100
R16-14V 06009 16-14 1/4 1.059 .472 100 R16-14N 07309 16-14 1/4 1.059 .472 100
R16-56V 06010 16-14 5/16 1.059 .472 100 R16-56N 07310 16-14 5/16 1.059 .472 100
R16-38V 06011 16-14 3/8 1.161 .590 50 R16-38N 07311 16-14 3/8 1.161 .590 50
R16-50V 06012 16-14 1/2 1.335 .748 50 R16-50N 07312 16-14 1/2 1.335 .748 50
R12-6V 06013 12-10 6 1.063 .374 50 R12-6N 07313 12-10 6 1.063 .374 50
R12-8V 06014 12-10 8 1.063 .374 50 R12-8N 07314 12-10 8 1.063 .374 50
R12-10V 06015 12-10 10 1.063 .374 50 R12-10N 07315 12-10 10 1.063 .374 50
R12-14V 06016 12-10 1/4 1.201 .472 50 R12-14N 07316 12-10 1/4 1.201 .472 50
R12-56V 06017 12-10 5/16 1.396 .591 40 R12-56N 07317 12-10 5/16 1.398 .591 40
R12-38V 06018 12-10 3/8 1.396 .591 40 R12-38N 07318 12-10 3/8 1.398 .591 40
R12-50V 06019 12-10 1/2 1.575 .756 40 R12-50N 07319 12-10 1/2 1.575 .756 40
R8-10V 06020 8 10 1.244 .472 25 R8-10N 07320 8 10 1.244 .472 25
R8-14V 06021 8 1/4 1.244 .472 25 R8-14N 07321 8 1/4 1.244 .472 25
R8-38V 06024 8 3/8 1.480 .591 25 R8-56N 07322 8 5/16 1.480 .591 25
R8-50V 06025 8 1/2 1.480 .591 25 R8-38N 07323 8 3/8 1.480 .591 25
R8-56V 06023 8 5/16 1.480 .591 25 R6-14N 07324 6 1/4 1.535 .472 15
R6-56N 07325 6 5/16 1.732 .630 15
R6-38N 07326 6 3/8 1.732 .630 15
R6-50N 07327 6 1/2 2.028 .866 15
R4-14N 07328 4 1/4 1.803 .649 15
R4-56N 07329 4 5/16 1.803 .649 15
R4-38N 07330 4 3/8 1.921 .689 15
R4-50N 07331 4 1/2 2.157 .866 15
R2-14N 07332 2 1/4 2.086 .602 10
R2-56N 07333 2 5/16 2.086 .602 10
R2-38N 07334 2 3/8 2.086 .602 10
R2-50N 07335 2 1/2 2.216 .866 10

Rated 600 volts, -40C to 105C.




Effective March 2007 www.nsiindustries.com NSi 3
Effective July 2006 www.nsiindustries.com NSi 3
Switches
ROCKER, ROTARY & MISCELLANEOUS SWTICHES


ROCKER, ROTARY & MISCELLANEOUS SWITCHES
RATINGS
CAT. UPC CIRCUIT POLES & AMPS AMPS H.P. 125- LAMP ACTUATOR CONNECTION CTN.
NO. CODE FUNCTIONS THROWS 125 VAC 250 VAC 250 VAC VOLTAGE COLOR CONTACT TYPE QTY.

A 77010RQ 77010 on off DPST 20 10 11/2@125,2@250 non-lighted black maintained .250 quikconnect 5
77040RQ 77040 on on DPDT 20 10 11/2@125,2@250 non-lighted black maintained .250 quikconnect 5
B
77060RQ 77060 on off on DPDT 20 10 11/2@125,2@250 non-lighted black maintained .250 quikconnect 5
77090RQ 77090 (on) off DPST 15 10 3/4 non-lighted black momentary .250 quikconnect 5
77100RQ 77100 (off) on DPST 15 10 3/4 non-lighted black momentary .250 quikconnect 5
C
77110RQ 77110 (on) on DPDT 15 10 3/4 non-lighted black momentary .250 quikconnect 5
D 77120RQ 77120 (on) off on DPDT 15 10 3/4 non-lighted black momentary .250 quikconnect 5
77130RQ 77130 (on) off (on) DPDT 15 10 3/4 non-lighted black momentary .250 quikconnect 5
DIMENSIONS IN INCHES A: 1.348 B: .750 C: .762 D: .422

A

B 77140RQ 77140 on off SPST 15 10 non-lighted black maintained .250 quikconnect 5

C
DIMENSIONS IN INCHES A: 1.250 B: .625 C: .828 D: .406
D

A
77150RQ 77150 on off SPST 15 7.5 red maintained .250 quikconnect 5
B



C
DIMENSIONS IN INCHES A: 1.250 B: .625 C: .828 D: .406
D

1st lens 2nd lens
77030RQ 77030 on off DPST 15 10 3/4@250 125V incand. red maintained .250 quikconnect 5
A
B 77020RQ 77020 on off DPST 15 10 3/4@250 125V neon amber maintained .250 quikconnect 5
77050RQ 77050 on on DPDT 15 10 3/4@250 125V incand. red amber maintained .250 quikconnect 5
77070RQ 77070 on off on DPDT 15 10 3/4@250 125V neon amber amber maintained .250 quikconnect 5
C
77080RQ 77080 on off on DPDT 15 10 3/4@250 125V neon red red maintained .250 quikconnect 5
E D DIMENSIONS IN INCHES A: .426 B: 1.088 C: .709 D: .345 E: 1.302
Description
77300RW 77300 on off SPST 3 1 non-lighted rotary canopy maintained wire leads 5
A


B
DIMENSIONS IN INCHES A: .718 B: .600 C: .265
C



77340RW 77340 on off SPST 6 3 non-lighted rotary canopy maintained wire leads 5
77320RW 77320 off on on on SPST 3 1 non-lighted rotary canopy maintained wire leads 5
A
DIMENSIONS IN INCHES A: 1.000 B: .844
B



79100MS 79100 on off SPST 6 3 feed through switch screws 5

B A

DIMENSIONS IN INCHES A: .844 B: .594 C: 1.375

C


A 79200MS 79200 N.C. & N.O. SPDT 5 magnetic feed switch screws 5
B



DIMENSIONS IN INCHES A: 2.500 B: .531


( ) Indicates momentary position All rocker switches are black phenolic bases with a black snap-in bexel and nylon actuator.


14 NSi Fax: 800.841.5566 Phone: 1.800.321.5847
14 NSi Fax: 800.841.5566 Phone Toll Free: 1.800.321.5847




Powered by Venture