|
|
||
| HOME |
|
|
* Quantity discounts may be available. Call 800-918-8939.
//freightCalculatorBox($item_details) ?>
Alternatively, you may e-mail info@kscdirect.com for service. |
BATTERY PACK,OPTIMAIR 6A[1]MSA MSA North America MSA is the global leader in the development, manufacture and supply of sophisticated products that protect people's health and safety. [9]MSA Customer Service [10]Customer Service 1-800-MSA-2222 [11]MSA Sales Manager Locator [12]Sales Manager Locator [13]Instrument Repair Services [14]Instrument Repair Services The Safety Company [15]HOME | [16]CATALOG | [17]LAW ENFORCEMENT/MILITARY PRODUCTS | [18]LAW ENFORCEMENT PRODUCTS | [19]TACTICAL/BALLISTICS EQUIPMENT | [20]OPTIMAIR 6A PAPR WITH OPTIFILTER CARTRIDGES | 491120 MSA Part Number: 491120 Engineering Description: BATTERY PACK,OPTIMAIR 6A Base Unit of Measure: EA Material Dimensions: 9.00 L X 6.50 W X 4.75 H Net Weight: 2.680 [21] MSA 2008. Keywords: MSA Mine Safety Appliances [14]Instrument Repair Services The Safety Company OptimAir 6A Replacement Parts [15]HOME | [16]CATALOG | [17]AIR-PURIFYING RESPIRATORS | [18]POWERED AIR PURIFYING RESPIRATORS (PAPRS) | OptimAir 6A Replacement Parts [19]Printable Version of This Page [20]Email This Page [21][OptimAir6AReplacePrtsPreview.jpg] Enlarge Image [pixel.gif] [pixel.gif] [pixel.gif] [pixel.gif] Principles of Operation Not applicable Approvals & Standards Not applicable Applications Asbestos Abatement Chemical Electric Utility Hazardous Materials Nuclear Oil and Gas Paper & Pulp Hazards Particulate and Dust Toxic Atmosphere Non-IDLH Welding Product Information See part numbers listed below Basic Info Additional Product Information * [22]Bulletin - Key Elements of a Sound Respiratory Protection Program (Bulletin No. 1000-61) Technical Information * [23]Instruction Manual - PAPR Flow Tester (Manual Part No. 490157) Literature How to Order From MSA: * [24]General Instructions * [25]Locate an MSA Distributor * [26]Locate an MSA Sales Manager Frequently Ordered Part Numbers: [27]463471 CHARGER,BATTERY, WITH LOW VOLTAGE INDIC. [28]486614 CHARGER,DUAL RATE,PAPR,PK [29]491102 MOTOR/BLOWER ASSY,OPTIMAIR 6A,BRUSH TYPE [30]491103 MOTOR-BLOW.OPT.6A BR/LESS [31]491120 BATTERY PACK,OPTIMAIR 6A Ordering Info [32] MSA 2008. Keywords: MSA Mine Safety Appliances [14]Instrument Repair Services The Safety Company Related Products [15]OptimAir Replacement Facepieces [16]OptimAir 6A Accessories [17]Towelettes [18]Bitrex Qualitative Fit Test Kit [19]Saccharin Qualitative Fit Test Kit [20]Banana Oil Fit Test Kit [21]Probed Respirator Facepieces for Fit Testing [22]Confidence Plus Germicidal Cleaner [23]OptimAir 6A Replacement Parts Related Resources [24]Response Respirator Selector [25]Cartidge Life Expectancy Calculator [26]Cartridge Change Test Program [27]Regulatory Information [28]Warranty Information [29]Ask a Question [30]Have Someone Call Me [31]Image Library OptimAir 6A PAPR with OptiFilter Cartridges [32]HOME | [33]CATALOG | [34]LAW ENFORCEMENT/MILITARY PRODUCTS | [35]LAW ENFORCEMENT PRODUCTS | [36]TACTICAL/BALLISTICS EQUIPMENT | OptimAir 6A PAPR with OptiFilter Cartridges [37]Printable Version of This Page [38]Email This Page [39][OptimAir6APreview.jpg] Enlarge Image [pixel.gif] [pixel.gif] [pixel.gif] [pixel.gif] Principles of Operation The OptimAir 6A powered air-purifying respirator (PAPR) provides respiratory protection by filtering contaminants from ambient air and providing air flow to either a facepiece or hood (with HEPA filters only) at a rate equal to or exceeding National Institute for Occupational Safety and Health (NIOSH) standards. Approvals & Standards The OptimAir 6A powered air-purifying respirator (PAPR) with Ultravue, Comfo, Comfo Elite, or Comfo Welder's facepieces or Tyvek hood has approvals from the National Institute for Occupational Safety and Health (NIOSH) and the Mine Safety and Health Administration (MSHA). Filters and cartridges are covered by separate approval. Cartridges must be replaced whenever air flow drops below four cubic feet per minute (115 lpm) with tight-fitting facepieces, six cubic feet per minute (170 lpm) with the Tyvek hood or when the user smells or tastes the contaminant. Applications Asbestos Abatement Chemical Electric Utility Hazardous Materials Nuclear Oil and Gas Paper & Pulp Sanding & Grinding Hazards Particulate and Dust Toxic Atmosphere Non-IDLH Product Information The OptimAir 6A powered air-purifying respirator (PAPR) can be used with an entire family of filters, chemical cartridges and combination cartridges for protection against particulates, toxic gases and vapors or a combination of these hazards. Requiring two filters, the unit is available with full- or half-mask facepiece, or hood. The belt-mounted motor/blower assembly includes an efficient 4.6 volt motor which has a long service life. The motor/blower assembly features threaded connectors for quick and easy attachment of OptiFilter cartridges. Basic Info Additional Product Information * [40]Bulletin - Personal Protection During Mold Remediation (Bulletin No. 5555-169-MC) * [41]Bulletin - Gas Masks for Law Enforcement (Bulletin No. 5555-166-MC) * [42]NIOSH Approval Label * [43]Bulletin - Key Elements of a Sound Respiratory Protection Program (Bulletin No. 1000-61) Technical Information * [44]Instruction Manual - Replacement Hood Kit for use with Versa-Hood Respirators (Manual No. 488790) * [45]OptimAir 6A Data Sheet No. 10-00-09 * [46]OptimAir 6A Instruction Manual (Part No. 490883) * [47]Instruction Manual - PAPR Flow Tester (Manual Part No. 490157) Literature How to Order From MSA: * [48]General Instructions * [49]Locate an MSA Distributor * [50]Locate an MSA Sales Manager Frequently Ordered Part Numbers: [51]492827 BELT ASSY.URETHANE PAPR [52]471218 FCPC UV PKG SM BK HYCAR W/NC & SD [53]480122 FCPC.HM,CHIN,S.E.MD HYCBL [54]480125 FCPC.HM,CHIN,S.E.MD SILBL [55]480127 FCPC.HM,CHIN,S.E.HYC BL [56]480130 FCPC.HM,CHIN,S.E.SIL BL [57]480132 FCPC.HM,CHIN,S.E.LG HYCBL [58]480135 FCPC.HM,CHIN,S.E.LG SILBL [59]481980 TUBE BREATHING HOOD,PAPR [60]484198 FCPC ASSY,HM,DN,CHK,SE,MD [61]484204 FCPC ASSY,HM,DN,CHK,SE,SM [62]484210 FCPC ASSY,HM,DN,CHK,SE,LG [63]486364 BREATHING TUBE ASSY,FCPC,PAPR [64]486485 HOOD,OPTIMAIR 6A PAPR,W/SUSP/LENS,SHLDR [65]488721 HOOD,OPTIMAIR 6A PAPR,W/O SUSP,TYVEK [66]808494 KIT,COVER,PROTECTIVE,6A P,5/PKG [67]10011890 CANISTERS,THREADED,P100/HE/CS/CN [68]463471 CHARGER,BATTERY, WITH LOW VOLTAGE INDIC. [69]484197 FCPC ASSY,HM,DN,CHK,SE,MD [70]484203 FCPC ASSY,HM,DN,CHK,SE,SM [71]484209 FCPC ASSY,HM,DN,CHK,SE,LG [72]486614 CHARGER,DUAL RATE,PAPR,PK [73]491102 MOTOR/BLOWER ASSY,OPTIMAIR 6A,BRUSH TYPE [74]491120 BATTERY PACK,OPTIMAIR 6A [75]491301 PAPR ASSY,OPTIMAIR 6A,WCART,W/TYVEK HOOD [76]494236 PAPR ASSY,OPTIMAIR 6A,W/O CART,MD ULTRAV [77]800749 OPTIMAIR 6A PAPR, MED,BLK [78]800767 OPTIMAIR 6A PAPR, MED,BLK [79]804564 TYVEK HOOD ASSY,PAPR,50UN [80]816892 OPTIMAIR 6A PAPR,MD,HYCAR [81]816912 BATTERY PACK, PACKAGED Ordering Info [82] MSA 2008. Keywords: MSA Mine Safety Appliances [14]Instrument Repair Services The Safety Company Related Products [15]OptimAir Replacement Facepieces [16]OptimAir 6A Accessories [17]Bitrex Qualitative Fit Test Kit [18]Saccharin Qualitative Fit Test Kit [19]Banana Oil Fit Test Kit [20]Probed Respirator Facepieces for Fit Testing [21]Confidence Plus Germicidal Cleaner [22]OptiFilter XL Prefilter/Cover Related Resources [23]Response Respirator Selector [24]Cartidge Life Expectancy Calculator [25]Cartridge Change Test Program [26]Regulatory Information [27]Warranty Information [28]Ask a Question [29]Have Someone Call Me [30]Image Library OptimAir 6A PAPR with OptiFilter Cartridges for Homeland Security Applications [31]HOME | [32]CATALOG | [33]AIR-PURIFYING RESPIRATORS | [34]POWERED AIR PURIFYING RESPIRATORS (PAPRS) | OptimAir 6A PAPR with OptiFilter Cartridges for Homeland Security Applications [35]Printable Version of This Page [36]Email This Page [37][6APAPRMillenniumPreview.jpg] Enlarge Image [pixel.gif] [pixel.gif] [pixel.gif] [pixel.gif] Applications Asbestos Abatement Chemical Electric Utility Hazardous Materials Nuclear Oil and Gas Paper & Pulp Sanding & Grinding Hazards Particulate and Dust Toxic Atmosphere Non-IDLH Welding Product Information Specifically designed to protect health care professionals from residual chemical/biological/radiological agents when they are performing first responder duties during homeland security or terrorist situations. Weighing less than six pounds, the system features a lightweight, chemical-resistant Tychem SL hood and belt-mounted blower with two HC CBA/RCA canisters. The canisters contain a pleated high-efficiency (P-100) filter to remove aerosols, radionuclides, and solid particulates, as well as an impregnated, activated carbon bed to adsorb (filter out) gases and vapors. The carbon bed is the same as used in military canisters and is effective against mustard (HD), Sarin (GB), DMMP (a Sarin simulant), HCN and CK. Approved for High Efficiency, Chlorine, Sulfur Dioxide, Hydrogen Chloride, Hydrogen Fluoride and Hydrogen Sulfide (escape only). The hood, which weighs approximately eight ounces, has a fully adjustable suspension and soft fabric collar for extended-wear comfort. Positive pressure inside the hood keeps contaminants out and eliminates the need for fit testing, so the comfortable, easy-to-don hood can be worn over eyeglasses, long hair and beards. Front and rear bibs provide neck-opening protection without restricting arm movement. A wraparound lens helps to minimize claustrophobia and provides excellent visibility. For efficient training and savings on batteries, a rechargeable NiCd battery can be substituted for the lithium battery, which provides a 10-year shelf life and four hours of wear time. Basic Info Additional Product Information * [38]Bulletin - Key Elements of a Sound Respiratory Protection Program (Bulletin No. 1000-61) * [39]NIOSH Approval Label * [40]Bulletin - Personal Protection During Mold Remediation (Bulletin No. 5555-169-MC) * [41]Bulletin - Gas Masks for Law Enforcement (Bulletin No. 5555-166-MC) Technical Information * [42]Instruction Manual - PAPR Flow Tester (Manual Part No. 490157) * [43]Instruction Manual - Replacement Hood Kit for use with Versa-Hood Respirators (Manual No. 488790) * [44]OptimAir 6A Instruction Manual (Part No. 490883) * [45]OptimAir 6A Data Sheet No. 10-00-09 Literature Ordering Information OptimAir 6A PAPR Kit,complete with medium Millennium Facepiece,lithium battery,belt,motor/blower module. Add OptiFilter cartridges/filters. 10046394 CBA/RCA OptiFilter Cartridges, Box of 6 10011890 Lithium Battery Pack for OptimAir 6A PAPR 816912 Motor/Blower Module 491102 Protective Covers, Package of 5 808494 Optional Battery and Charger Rechargeable NiCad Battery 491120 Standard Single-Unit Battery Charger 463471 Single-Unit, Dual-Rate Battery Charger 486614 How to Order From MSA: * [46]General Instructions * [47]Locate an MSA Distributor * [48]Locate an MSA Sales Manager Ordering Info [49] MSA 2008. Keywords: MSA Mine Safety Appliances Keywords: MINESA MSA 491120 MINE SAFETY APPLIANCES CO BATTERY PACK,OPTIMAIR 6A Category: [0] => SUPPLIER DIRECTORY => MINE SAFETY APPLIANCES CO, MSA => MSA - MINE SAFETY APPLIANCES - SECTION 81 Buy MSA Mine Safety Appliances Products and Replacement Parts |
