LOW VOLT, VERT. MOUNT 180-240F, W/50 VA TRANSFORMER, WELL ADAPT AND HT. ...
| Product Specifications | | | | Description | High Limit Aquastat Relay with 15 F fixed differential | | Operating Range, High Limit (F) | 120 F to 240 F | | Operating Range, High Limit (C) | 54 C to 116 C | | Differential Temperature (F) | 15 F fixed | | Switching Action | SPST: High Limit & Circulator | | Anticipator Setting | 0.2 A | | Maximum Operating Pressure (psi) | Immersion Well: 255 psi | | Maximum Operating Pressure (kPa) | Immersion Well: 1757 kPa | | Electrical Ratings (ALR) | 44.4A @ 120 Vac | | Electrical Ratings (ALR) | 22.2A @ 240 Vac | | Electrical Ratings | 0.25 A @ 0.25 to 12 Vdc | | Electrical Ratings (burner AFL) | Line Voltage: 7.4 A @ 120 Vac; 3.7 A @ 240 Vac | | Electrical Ratings (burner AFL) | Low Voltage: 0.8 A max. @ 24 Vac | | Electrical Ratings (burner ALR) | Line Voltage: 44.4 A @ 120 Vac; 22.7 A @ 240 Vac | | Electrical Ratings (burner millivolt) | 0.25 A @ 1/4 to 12 Vdc | | Electrical Ratings (circulator AFL) | 3.7 A @ 240 Vac | | Electrical Ratings (circulator AFL) | 7.4 A @ 120 Vac | | Electrical Ratings (circulator ALR) | 44.4 A @ 120 Vac | | Electrical Ratings (circulator ALR) | 22.7 A @ 240 Vac | | Capillary Length (in.) | 4 1/2 in. | | Capillary Length (mm) | 114 mm | | Dimensions (in.) | 6 1/8 in. high x 4 5/16 in. wide x 3 1/8 in. deep | | Dimensions (mm) | 156 mm high x 110 mm wide x 79 mm deep | | Insulation Depth (in.) | 1 1/2 in. to 3 in. less well. | | Insulation Depth (mm) | 38 mm to 76 mm less well | | Operating Humidity Range (% RH) | 0 to 95% RH, non-condensing | | Maximum Ambient Temperature (F) | 150 F with 1.2 A 24 V load; 77 F with 1.4 A 24 V load | | Maximum Ambient Temperature (C) | 66 C with 1.2 A 24 V load; 25 C with 1.4 A 24 V load | | Electrical Connections | Quick-Connect / Screw | | Approvals, Underwriters Laboratories Inc | UL Listed: File No. MP466, Vol. 13, Sec. 2, Guide No. MBPR2. | | Approvals, Canadian Standards Association | Certified: File No. LR95329-1 | | Includes | 50 VA transformer and heat conductive compound. | |
Keywords: HONEYW HON L8148E1299 L8148E1299 HONEYWELL, INC 085267163668 LOW VOLT, VERT. MOUNT 180-240F, W/50 VA TRANSFORMER, WELL ADAPT AND HT. ... Category: [0] => SUPPLIER DIRECTORY => HONEYWELL, INC => HONEYWELL THERMOSTATS, ELECTRIC, VALVES, PARTS, ETC SECTION 32 [1] => SUPPLIER DIRECTORY => HONEYWELL, INC => HONEYWELL REPLACEMENT PARTS => Honeywell Multi-function => SUPPLIER DIRECTORY => HONEYWELL, INC => HONEYWELL THERMOSTATS, ELECTRIC, VALVES, PARTS, ETC SECTION 32
|