1 QT REAL TUFF THREAD SEALANT





OP EN W IDE

(R)

Spec Sheet #S00211September 2002 OPEN WIDE(R) Drain Opener

Dra in O

pen er OPEN WIDE can be used for slow running or completely clogged drains. A crystal drainopener which works faster than any liquid caustic or bleachedbased openers and is more economical to use. Will not solidify in drains. Does not produce dangerous gases orfumes. Low heat formula makes OPEN WIDE safe for all plumbing, including toilets* and septic systems, when used as directed. Contains no metals and will not stain or discolor porcelain. OPEN WIDE will remove many organic stains in sinks, tubs, and toilets. Special ingredients neutralize odors within seconds. Opens most drains in minutes, yet is safe to leave in drain line overnight. Effervescent formula is selfdissolving and works through hot or cold standing water. Flush with hot water. * Not for clogged toilet bowls

STOCK NO. SIZE PACKING WEIGHT/CASE 271131 1 lb. 12 14 lbs.

SIZES AND PACKING

DESCRIPTION

Spec Sheet #S00211

CLOROBEN PRODUCTSHercules Chemical Company, Inc. 111 South Street, Passaic, NJ 070559100Phone: 8002219330 * Fax: 8003333456 email: cloro@herchem. com (C)2002 HCCI ERA

APPROVALS AND LISTINGS SPECIFIC USES

SPECIFIC APPLICATIONS* Safe for use on all plumbing fixtures, plastic pipe, and septic systems.

PHYSICAL PROPERTIES Density: 1. 20 pH: 10% solution = 14. 0 Solubility in Water: Appreciable: 42g/100cc of water at 0oC. Odor: Odorless Appearance and color: White to offwhite granular solid

WARNINGS OR CAUTIONS

* Do not use OPEN WIDE before, with, mixed with, or after any other chemicals. Mayreact violently with acids and bleach.

* Read all cautions and directions carefully before using this product.

* Store in a cool, dry area. Replace cap tightly and secure after use.

* Do not get in eyes, on skin, or on clothing. Wear eye protection and rubber gloves. Avoid contact with skin and eyes. Wash thoroughly after use.

* Avoid breathing dust, mist, spray or vapors. Use with adequate ventilation.

* DO NOT wear contact lenses.

* Do not take internally.

* Never add water to container, violent reaction will occur.

* Never use plunger or pressure device in plumbing which may contain OPEN WIDE.

* Rinse empty container before discarding.

* Store only in this container. Do not reuse empty container.

* Not for use in clogged toilet bowls, garbage disposals, dishwashers, or clotheswashers.

* Do NOT use on aluminum or galvanized material, some floor coverings, wood,enameled or painted surfaces. Rinse immediately with water to minimize damage.

Not applicable. Use Cloroben OPEN WIDE for slow running or completely clogged drains. Can beused as a preventive maintenance product to keep drain free flowing and odor free.

OPEN WIDE(R)Drain Opener

MATERIAL SAFETY INFORMATION FOR MORE INFORMATION ON THIS PRODUCT, REQUEST MATERIALSAFETY DATA SHEET (MSDS) #211

HMIS Hazard warning 202E INGREDIENTS CAS# Sodium Hydroxide 1310732Sodium Percarbonate 15630894

Sodium Carbonate 497198

* For special applications which may not be covered on this or otherCloroben literature, please contact Cloroben Technical Services

Department by phone at 18002219330 or send a fax to 18003333456.

DIRECTIONS FOR USE OPENING CLOGGED DRAINS: Remove drain strainer sieve and/or standing waterfrom drain and drainage area. Add 2 oz. (4 Tbsp.) of OPEN WIDE directly to drain. Allow to work for at least 15 minutes or even overnight. Flush with hot water. If system is not completely restored, repeat application 1 time only. PREVENTIVE MAINTENANCE AND ODOR CONTROL: Once a week remove drainstrainer sieve and add 1 oz. (2 Tbsp.) directly to drain. Let stand for at least 1 hour before reusing drain. Flush thoroughly with hot water until clear. This will keepdrains free flowing, clean and odor free. BOWL CLEANER AND DEODORIZER: For stains in toilet bowls, add 1 oz. (2 Tbsp.)directly to standing water. Scrub with a brush. Let the chemical action work for 15 minutes. Flush twice. For hard to remove stains, repeat application. Rinse brushthoroughly in bowl water before storing. Not for use in clogged toilet bowls.

For Delivery by Fax Call 18009424636 Internet See MSDS section of www. cloroben. com Mail Contact Cloroben at address below or any Cloroben representative




Aid Ox

(TM)

Restores drainage in clogged or sluggish drainfields or cesspools. Detoxifies, drainsand deodorizes stagnant drainage areas, enhancing conditions for aerobic bacterial growth. Oxygenbased foaming porosity restorer and cleaner formulated to open clogged gravel beds, surrounding cesspools, seepage pits, drywells, and drainfields. Freeflowing andselfdispersing dry crystalline form of hydrogen peroxide, which breaks down into nontoxic, nonpolluting byproducts such as oxygen, water and naturally occurringminerals. Contains no acids, caustics or organic solvents. Must be added directly to cesspool,seepage pit, distribution box or cleanout leading directly into the drainage area. When added to the standing water in the main access port of a cesspool, seepage pit, or distribution box, AIDOx dissolves the sealing crust and reconditions the biomat allowing proper drainage of the cesspool or drainfield. Use on a periodic basis to maintain undersized or heavily stressed systems. Environment and consumer safe.

STOCK NO. SIZE PACKING WEIGHT/CASE 252034 9 lbs. 4 38 lbs. 252043 45 lbs. 1 46 lbs.

SIZES AND PACKING

DESCRIPTION

Spec Sheet #S00201March 2002 AIDOx(TM) Septic Products

Sep tic Pro duc ts

Spec Sheet #S00201

CLOROBEN PRODUCTSHercules Chemical Company, Inc. 111 South Street, Passaic, NJ 070559100Phone: 8002219330 * Fax: 8003333456 email: cloro@herchem. com (C)2003 HCCI JRZY

APPROVALS AND LISTINGS SPECIFIC USES

SPECIFIC APPLICATIONS* Cloroben AIDOx restores septic drainfields and cesspools.

PHYSICAL PROPERTIES Solubility: 14%Odor: Odorless

Appearance and color: White freeflowing granular powder

WARNINGS OR CAUTIONS

* Read all cautions and directions carefully before using this product.

* Avoid contact with eyes, skin and open wounds. Do not breathe dust.

* Do not take internally.

* Do not mix with any other chemical. Keep away from water, metallic objects, andexcessive heat.

* Avoid contact with food.

* Store in original container and keep lid closed. Do not transfer to any other container.

* Store in cool, dry place.

* DISPOSAL: Sweep up and place in closed container for disposal. Flush residuals to drain. Avoid contact with combustibles.

* Dispose of in accordance with local, state and federal regulations.

* Use only dry clean plastic or stainless steel utensils. NOTE: AIDOx is an oxidizing agent. It reacts quickly when contacted with water andmetallic objects. This reaction releases heat and oxygen gas which may

create enough internal pressure to burst closed container.

Use Cloroben AIDOx when a drainage system is sluggish in flow, waterlogged withponding or emitting foul odors. Should also be used when a recently pumped system fills and backs up again; indicating the drainage area is nonporous.

AIDOx(TM)Septic Products

For Delivery by Fax Call 18009424636 Internet See MSDS section of www. cloroben. com Mail Contact Cloroben at address below or any Cloroben representative

MATERIAL SAFETY INFORMATION FOR MORE INFORMATION ON THIS PRODUCT, REQUEST MATERIALSAFETY DATA SHEET (MSDS) #201

HMIS Hazard warning 201B INGREDIENTS CAS# Sodium Percarbonate 15630894Sodium Carbonate 497198

Sodium Metasilicate 6834920

* For special applications which may not be covered on this or otherCloroben literature, please contact Cloroben Technical Services

Department by phone at 18002219330 or send a fax to 18003333456.

DIRECTIONS FOR USE RESIDENTIAL SYSTEM RESTORATION: AIDOx must be added directly to the drainage area. Foran average residential system (with a 1,000 gallon or less tank and corresponding drainage area) a total of four 1gallon containers will be required. CESSPOOLS, SEEPAGE PITS, AND DRYWELLS: Any floating surface mat andbottom sludge should first be pumped out. The water level in the vessel should

be at least twothirds full before adding AIDOx. AIDOx will clean only the areasbelow the water level, such as the sidewalls where most drainage takes place. Use one container each day for three days. A noticeable drop in the water level is oftenseen during this period. On the fourth day add a portion of the fourth bottle corresponding to the level of water in the tank. EXAMPLE: If the tank is halfempty,use a half bottle of AIDOx. Add similar amounts on following days until the last bottle of AIDOx is finished. DRAINFIELDS AND BED SYSTEMS: AIDOx may be added to standing water inthe distribution box of drainfields or to the main line leading into the header manifold or main outlet of a septic tank in bed systems. For faster more effectiveresults pump excess water from drainage areas first. For drainfields divide the contents of one container between the laterals. Using a 3'' diameter stand pipeand street elbow inserted into one lateral at a time add AidOx. For both drainfields and bed systems use water to flush the powder through to the drainage area. Repeat the procedure for two more days. Beginning on the fourth day, use one quarter of a bottle of AIDOx each day for four more days. Wait at least one weekbefore adding any starter bacterial products. Severely clogged systems may require a second treatment. Allow the first treatment to work for at least twoweeks before deciding if a second treatment is necessary.

NOTE: Inaccessible laundry drywells can be treated by slowly adding AIDOx intoa drain leading directly to drywell. Use a sufficient stream of water to carry the powder down the drain. Inaccessible drainfields can be treated by adding AIDOxthrough a clean out past the septic tank, or by using a funnel and hose inserted in the tank outlet. Flush through with water. PREVENTIVE MAINTENANCE: Marginal or older, sluggish systems can be maintained in good working order with a periodic dose of AIDOx. For residential systems, add a halfgallon of AIDOx directly to the drainage facility once or twice ayear as needed. The installation of a standpipe with a removable lid will make periodic treatments more convenient. COMMERCIAL AND MUNICIPAL SYSTEM RESTORATION: Calculate the Daily Treatment Requirement (DTR) in gallons by adding the capacity of the septic tank or cesspool plus daily water usage.

Add a halfpound of AIDOx for each 100 gallons of DTR for three consecutivedays. Follow with 1 pound per day for every 1,500 gallons of DTR for 20 additional days. Example: A commercial system with 5,000 gallons of DTR requires 25pounds per day for three days followed by 3 pounds per day for twenty days. Refer to the RESIDENTIAL instructions for areas to add product and for pumpingrequirements. PREVENTATIVE MAINTENANCE: Sluggish systems can be kept in good workingorder with a periodic dosage of AIDOx. Use one 9 pound bottle for 2,000 gallons of DTR once or twice a year as needed. The installation of a standpipe with aremovable lid will make periodic treatments convenient.

Massachusetts Title V




Spec Sheet #S00011March 2007RealTuff Thread Sealant

Multipurpose heavy duty, white, PTFE paste thread sealant for use onAluminum, Black Iron, Brass, Copper, Glass, Monel, Natural Rubber, Plastic (P. E.,Reinforced), PVC, ABS, CPVC, Stainless Steel, Synthetic Rubber (Butyl,Neoprene). Contains a unique system of fine grain PTFE particles specifically designed to fill cracks and tiny thread imperfections. Leak free joints can be tested and put into service at once. RealTuff holds tight against expansion, contraction and vibration, is nonseparating, will not run or drip from joints, contains no lead. Nonhardening lubricating formula permits low torque makeup and easy disassembly without galling or stripping threads. RealTuff withstandstemperatures from 200oF to +550oF, and provides leakproof hydraulic resistance to 12,000 psi. Withstands gas pressure up to 2,600 psi. RealTuff is nonflammable and contains no heavy metals or volatile solventsand is applied easily with a natural bristle brush, even at temperatures as low

as 25oF.

STOCK NO. SIZE PACKING WEIGHT/CASE 15605 2 oz. tube 48 (41 doz. trays) 7. 7 lbs. 15615 1/4 pt.* 24 11. 5 lbs.

15620 1/2 pt.* 24 22. 5 lbs. 15625 1 pt.* 12 23. 0 lbs. 15630 1 qt. 12 44. 7 lbs. 15632 1 qt.* 12 44. 0 lbs. 15635 1 gal. 4 58. 1 lbs. 15640 5 gal. 1 65. 0 lbs.

*brushincap

SIZES AND PACKING

DESCRIPTION

TM

Re alTuf

f

TM

RealTuffThread Sealant

SPEC SHEET #S00011

Hercules Chemical Company, Inc. 111 South Street, Passaic, NJ 070559100 Phone: 8002219330 * Fax: 8003333456 email: info@herchem. com http://www. herchem. com

APPROVALS AND LISTINGS

SPECIFIC USES

For Delivery by Fax Call 18009424636 Internet See MSDS section of www. herchem. com

Mail Contact Hercules at address below orany Hercules representative

SPECIFIC APPLICATIONS* RealTuff may be used on these materials: Aluminum,Black Iron, Brass, Copper, Glass, Monel, Natural Rubber,

Plastic (P. E.,Reinforced), PVC, ABS, CPVC, Stainless Steel,Synthetic Rubber (Butyl, Neoprene).

PHYSICAL PROPERTIES Pressure Rating: Liquids 12,000 psiGases 2,600 psi

Temperature Performance: 200oF to +550oFBrushability: 25oF

WARNINGS OR CAUTIONS Not for oxygen lines.

DIRECTIONS FOR USE Stir well before use. Do not dilute. For best results applyRealTuff to clean dry male threads, brushing well into the

roots of the threads. Finished joints can be tested and putinto service at once. There is no set up time necessary. Shelf life is approximately23 years.

MATERIAL SAFETY INFORMATION FOR MORE INFORMATION ON THIS PRODUCT,REQUEST MATERIAL SAFETY DATA SHEET (MSDS) #11.

This product is not classified as hazardous in accordancewith 20 CFR OSHA 1910. 1200. HMIS Hazard Warning 000A.

INGREDIENTS CAS# NJT. S. R. #31348300 5005P, 5010P, 5014P, 5015P, 5016P

* For special applications which may not be covered on this or other

Hercules literature, please contact Hercules Technical Services Department by phone 18002219330, or fax 18003333456, or visit our technical database website at www. herchem. com.

TM ANSI/NSF61 FED SPEC TTS1732 For Potable Water.

Real Tuff can be used onlines carrying: AcidsConcentratedAcidsDilute Air Compressed(Gaseous) AlcoholsAliphatic Solvents Ammonia AnhydrousAmmonia Gaseous Ammonia LiquefiedAromatic Solvents BenzeneBrine Butane Gas

Carbon DioxideCarbon Tetrachloride Castor OilsCaustic Alkalies

(concentrated)Caustic Alkalies (dilute) Coal GasCoal Tar Naptha Cutting OilsDiesel Fuel Oil Dry Cleaning FluidsEthylene Glycol Fatty Acid (liquid)Freons (all) Gasohol

GasolineGlycerine Heating OilsHelium Gaseous Hydraulic OilsHydrogen Inert GasesJet Fuel KeroseneKetones Liquefied Pet. GasesLubricating Oils Manufactured GasesMineral Oils Natural Gas

Nitrogen GaseousPetroleum Solvents PropanePropylene Glycol Soap LiquidSugar Liquid SteamToluene TriChloroEthyleneVegetable Oils Water (cold & hot)Water Gas Xylene

ISO 9001: 2000 Certified (C)2007 HCCI / KA / EW / 0307 / 2000




Powered by Venture
Open Source ERP Software